12.Press the key. (Address section starts flashing.) LCD display
862 88D3 FC
This section (address) flashes.
13.Press the key to return to Manual mode. LCD display
862 VarWrt 00
14.Press the |
|
|
| key and write in the correction data. |
|
|
|
24.Press the key to return to Manual mode. LCD display
862 VarWrt 01
Data value.
25.Press the key and write in the correction data. 26.Turn off the power.
Note: Always turn off the power after changing the adjustment set- tings.
15.Press the > key and 862 as the item number. LCD display
862 VarWrt 01
Data value.
16.Press the key, and set in Adjustment change mode. LCD display
862 88C6 FF
This section (address) flashes.
17. Press the x key . (FF section (data) flashes)
18.Press the VOL + and VOL – key and set the value in the flashing data section while referring to the adjustment data change list.
LCD display
Adjustment Data Change List
If adjustment data is VarWrt is 00
Version 1.000
Address | Adjustment Data |
88C6 | 3F |
|
|
88C7 | 03 |
|
|
88C8 | D6 |
|
|
88C9 | 22 |
|
|
88CA | C4 |
|
|
88CB | 37 |
|
|
88CC | C2 |
|
|
88CD | 04 |
|
|
88CE | E8 |
|
|
88CF | 42 |
|
|
88D0 | 6E |
|
|
88D1 | FC |
|
|
88D2 | 71 |
|
|
88D3 | FC |
|
|
If adjustment data is VarWrt is 01
Version 1.000
Address | Adjustment Data |
88C6 | 07 |
|
|
88C7 | 8D |
|
|
88C8 | FF |
|
|
88C9 | FF |
|
|
88CA | FF |
|
|
88CB | FF |
|
|
88CC | FF |
|
|
88CD | FF |
|
|
88CE | FF |
|
|
88CF | FF |
|
|
88D0 | FF |
|
|
88D1 | FF |
|
|
88D2 | FF |
|
|
88D3 | FF |
|
|
862 88C6 07
Data value.
19.Press the key, and the address section starts flashing. 20.Press the VOL + key and set the next adjustment address.
LCD display
862 88C7 FF
This section (address) flashes.
21. Press the x key . (FF section (data) flashes) LCD display
22.Press the VOL + and VOL – key and set the value in the flashing data section while referring to the adjustment data change list.
LCD display
862 88C7 8D
Data value.
23.Press the key, and the address section starts flashing.
5-4. POWER SUPPLY VOLTAGE ADJUSTMENTS
5-4-1. Adjustment sequence
The adjustments should be always performed in the following se- quence:
1LEG1 adjustment (item No.:741)
r
2 VC1 adjustment (item No.:742) r
3 VC2 adjustment (item No.:743) r
4
5-4-2. REG1 adjustment method
1.Supply power (DC 6.0 volts) from the charging terminal CN951.
2.Set the Test mode.
3.Set the overall adjustment mode and press P.MODE/F key, item No. will change to 741.
LCD display
741 Reg1 XX
4.Connect a digital voltmeter to TP908 (REG1) on the main
board and adjust VOL + (voltage up) key and VOL – (voltage down)key on the remote control.
12