MZ-E10
SECTION 4
TEST MODE
4-1. GENERAL
•When entered in the TEST MODE, this set provides the Overall Adjustment mode which allows CD and MO discs to be auto- matically adjusted. In the Overall Adjustment mode, the system discriminates between CD and MO discs, performs adjustments in sequence automatically, and displays the faulty location if any fault is found. In the Manual mode, selected adjustments can be performed automatically.
•The attached remote control is used to operate the TEST MODE. Unless otherwise specified in the text, the key means that on the remote control.
4-2. SETTING THE TEST MODE
To set the TEST MODE, two methods are available.
1Solder bridge and short TAP602 (TEST) on the main board. Then turn on the power.
Remote control LCD
| 000 | F 1SHUFPGM SOUND | 8 |
u | |||
|
|
|
All on
All off
001V1.000
Microprocessor version display
MAIN BOARD (SIDE A)
12 7
13 | 6 |
IC951
18 1
1924
R965 C954
R964 |
| C957 | ||
C958 | R959 | R961 | ||
1 | ||||
|
|
| ||
| CN951 |
| ||
2 | 956 | C928 | ||
| C960 | |||
|
|
C953
R956 R958 R957
|
|
| FB601 | |
| E |
| R627 |
|
|
| C617 | R | |
|
|
| ||
Q951 |
|
|
| |
|
|
|
| |
|
| C612 |
|
|
| TAP602 |
|
|
| R607 |
| (TEST) |
|
|
| |
| D951 |
|
| C607 | C608 |
|
|
|
| ||
| R604 | R623 | R620 | C606 | |
1 | 5 | R621 | R622 | ||
|
|
|
| ||
|
|
| 8 8 |
TAP602
SHORT: TEST MODE
OPEN: NORMAL MODE
•Press and hold down to hold the current display while the key is being pressed.
When method 1 was used:
Turn off the power and open the solder bridge on TAP602 on the main board.
Note: The solder should be removed clean. The remaining solder may make a short with the chassis and other part.
When method 2 was used: Turn off the power.
Note: If electrical adjustment (see page 11) has not been finished completely, always start in the test mode.
4-3. TEST MODE STRUCTURE
Test Mode
(Display Check Mode)
VOL + key |
Manual Mode |
x key |
Servo Adjustment |
2In the normal mode, operate the keys on the set and those on the remote control as specified below:
Turn on HOLD switch on the set. Holding down x (STOP)
key on the set, press the keys on the remote control in the following sequence:
>t > t . t . t > t . t > t . t tWhen the TEST MODE is entered, the system switches to the dis- play check mode within the TEST MODE. From this mode, the other Test modes can be accessed.
When the TEST MODE is set, the LCD repeats a cycle of the fol- lowing displays:
Audio Adjustment |
Power Supply Voltage Adjustment |
Charge Adjustment |
VOL key |
Overall Adjustment Mode |
x |
key |
CD/MO Adjustment |
Power Supply Voltage Adjustment |
NV Initialize |
(Clear the |
+ key or DISPLAY key |
(Press and hold down about for more than2 sec) |
Key Check Mode |
Terminate key checking or open the top panel.
8