1.Connect TP953 to TP959 on the main board.
2.Set the test mode.
3.Set the Manual mode and set the item No. to 752.
LCD display
752 ChgI L XX
4. Press key to write the adjustment value.
4. | Adjust with the remote control | VOL + | and | VOL – | keys so | ||||
| that the temperature value is at room temperature. | ||||||||
| Reset value: | 19h = 25 C | |||||||
| Adjustment range: 80h to 7Fh = | ||||||||
|
|
|
|
|
| ||||
5. | Press the |
|
|
| key and write in the adjustment value. | ||||
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
(when using Version 1.000)
1.Set in Manual mode and then set item number 026. LCD display
026 NvWrt CC
2.Press the key. LCD display
026 8200 **
TEST MODE (Display Check Mode)
VOL — key
Overall Adjustment Title Display(ASSY**)
.key
CD overall | x key |
Adjustment
> key
This section (address) flashes.
3.Press the key (100th place) and the VOL + key (10th place) and set 828A in the flashing address section.
LCD display
026 828A **
4. Press the x key. |
| > key | MO overall | |
|
|
| |
|
|
| Adjustment |
key two times
NV Initialize
P.MODE/F key Power Supply Adjustment
xkey
xkey
xkey
LCD display |
026 828A **
This section (data) flashes.
5.Press the VOL + and VOL – keys and set 00 in the flashing data section.
LCD display
026 828A 00
6.Press the key.
7.Press the key to return to Manual mode. LCD display
026 NvWrt CC
8. Press the key and write in the adjustment setting.
[Temperature adjustment method]
1.Set in Test mode.
2.Set in Manual mode and set the item number 014. LCD display
014 AdjTmp XX
Item No. | Adjustment setting |
3. Measure the temperature.
Note: The overall adjustments should be always performed in the sequence of CD t MO adjustments.
Switching to Total Adjust Mode sets the following All Adjust mode title display on the LCD.
LCD display
000 Assy **
: Disk mark (outer) lights up when power adjustment is com-
plete.
Disk mark (inner) not used
**: Left side is MO alignment information F* : MO total alignment is complete
1* : Manual alignment (not part of total adjustment)
0* : Not adjusted
Right side is CD alignment information F* : CD total alignment is complete
1* : Manual alignment (not part of total adjustment)
0* : Not adjusted
1. Set the TEST MODE and press VOL – key to set the Overall Adjustment mode.
LCD display
000Assy11
15