4-4. MANUAL MODE
The Manual mode is designed to perform adjustments and operational checks on the set’s operation according to each individual function.
The Manual mode is used to clear the memory before performing automatic adjustments in the Overall Adjustment mode.
4-4-2. How to set the Manual mode
1.Set the TEST MODE and press VOL + key to set the Manual mode.
Remote control LCD display
000Manual
2. During each test, press and hold down > key or .
key for a while to move the optical pickup on the sled outer or inner perimeter.
3.Each test item is assigned with a
Note: Changes in adjustment item settings are written into the
4.During each test mode, the display is changed from one to another each time DISPLAY key is pressed.
•Item title Display LCD display
011 Lrefpw 3F
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Item title |
|
|
|
| |
|
|
|
|
| adjusted value | |||||
mode number |
|
| ||||||||
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
•Address & Adjusted Value Display LCD display
011 AAAS 3F
|
|
|
|
|
|
|
|
|
|
| adjusted value |
|
|
|
|
|
|
|
|
|
|
| |
mode number | address |
|
| ||||||||
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
•Jitter Value & Adjusted Value Display LCD display
011 OFFJ 3F
|
|
|
|
|
|
|
|
|
|
| adjusted value |
|
|
|
|
|
|
|
|
|
|
| |
mode number | jitter value |
|
|
| |||||||
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
• Block Error Value & Adjusted Value Display |
LCD display |
Change Major
Item
|
|
|
|
|
|
| key |
| x key | ||
|
| ||||
> |
| ||||
|
|
|
|
| |
|
|
|
|
|
|
|
| Change Middle |
| ||
|
| Item |
|
|
|
| key |
| x key | ||
|
| ||||
> | |||||
|
|
|
|
| |
|
|
|
|
|
|
|
| Change Minor |
| ||
|
| Item |
|
|
|
VOL+ key : 100th place of mode number increase
VOL key : 100th place of mode number decrease
VOL+ key : 10th place of mode number increase
VOL key : 10th place of mode number decrease
>key : Unit place of mode number increase
.key : Unit place of mode number decrease
011 000B 3F
|
|
|
|
|
|
|
|
|
|
| adjusted value | |
|
|
|
|
|
|
|
|
|
|
| ||
mode number |
|
|
|
|
|
| ||||||
block error value | ||||||||||||
|
|
|
|
|
•ADIP Error Value & Adjusted Value Display LCD display
011 000A 3F
|
|
|
|
|
|
|
|
|
|
| adjusted value |
|
|
|
|
|
|
|
|
|
|
| |
mode number | ADIP error value |
•Focus drive voltage value & Adjusted value LCD display
Change Adjustment | VOL+ | key : Up |
Value | VOL | key : Down |
Write Adjustment |
|
|
Value |
|
|
key : When adjusted value is changed : | ||
Adjusted value is written. |
| |
When adjusted value is not changed : | ||
That item is adjusted automatically. |
011 000F | 3F | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| adjusted value | |
|
|
|
|
|
|
|
|
|
|
|
| ||
mode number |
|
|
| ||||||||||
|
|
|
|
|
|
| |||||||
Focus drive voltage value | |||||||||||||
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Note: In the Power mode, the item title display is only displayed.
5.To terminate the Manual mode and return to the TEST MODE, press x key.
4-5. OVERALL ADJUSTMENT MODE
4-5-1. Outline of the function
This mode is designed to adjust the servo system automatically by going through all the adjustment items.
Usually, this mode is used to perform automatic adjustments when servicing the set.
For further information, refer to section 5. ELECTRICALADJUST- MENTS. (See page 11)
9