Adjustment value:1.05V Standard value:1.04 to 1.055V
MAIN BOARD (SIDE A)
| C C |
TP908 |
|
(REG 1) | C910 |
37
C202
R921
R908
3.Press key to write the adjustment value, item No. will change to 743.
1.Set the overall adjustment mode and set the item No. to 743. LCD display
743Vc2 XX
2.Connect a digital voltmeter to TP907(VC2) on the main board
912 | R911 |
|
|
| C916 |
| C922 | C908 |
digital voltmeter | ||
|
| TP908 |
|
| (REG1) |
C926
L904
1-686-492-
and adjust VOL + key (Voltage down) and
(Voltage up) on the remote control. Adjustment value:1.15V Standard value:1.15 to 1.18V
MAIN BOARD (SIDE A)
TP907
(VC2) R921
R908
C910
12 R911
C916
VOL – key
C926
L904
5.Press key to write the adjustment value, item No.will change to 742.
C922 | C908 |
1.Set the overall adjustment mode and set the item No. to 742. LCD display
742Vc1 XX
2.Connect a digital voltmeter to TP902 (VC1) on the main board
and adjust VOL + key (Voltage up) and VOL – key (Voltage down) on the remote control.
Adjustment value:2.15V Standard value:2.14 to 2.155V
MAIN BOARD (SIDE A)
digital voltmeter
TP907(VC2)
3.Press key to write the adjustment value, item No. will change to 744.
1.Set the overall adjustment mode and set the item No. to 744. LCD display
744 Cls D XX
R921
R908
| C910 |
12 R911 | TP902(VC1) |
| C916 |
C922 | C908 |
digital voltmeter
TP902
(VC1)
C926
L904
2.Connect a digital voltmeter to TP909
board and adjust VOL + key (Voltage up) and VOL – key (Voltage down) on the remote control.
13