COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001
CHAPTER 5 SERVICE MODE
5-22 T<DC-CON (2/7)>
Address
bit
Notation
Description Remarks
P005 0 M6 duplex motor pulse signal IN1 -
1 M6 duplex motor pulse signal IN2 -
2 M6 duplex motor pulse signal IN3 -
3 M6 duplex motor pulse signal IN4 -
4 M6 duplex motor drive signal I0 -
5 M6 duplex motor drive signal I1 -
6 FM4 curl reducing fan 1 drive signal 1: ON
7 FM5 curl reducing fan 2 drive signal 1: ON
P006 0 primary DC charging motor signal 1: ON
1 primary charging ON signal 1: ON
2 static eliminator ON signal 1: ON
3 developing AC bias ON signal 1: ON
4 developing DC bias ON signal 1: ON
5 fixing bias ON signal 1: ON
6 heater relay ON signal 1: ON
7 M8B 2-way delivery outlet motor pulse signal I0 1: 70%, 0: 100%
P007 0 transfer mode signal 0 1: ON
1 transfer mode signal 1 1: ON
2 transfer mode signal 2 1: ON
3 transfer mode signal 3 1: ON
4 transfer ON signal 1: ON
5 scanner output signal 4 -
6 scanner output signal 5 -
7 not used
P008 0 S1 toner level detection signal 1: toner present
1 not use
2 S2 waste toner case full detection signal 1: full
3 M1 main motor lock detection signal 0: locked
4 M10 laser scanner motor lock detection signal 0: locked
5 M4 fixing motor lock detection signal 0: locked
6 24V detection signal 0: detected
7 SW3 front over open/close sensor signal 1: closed
P009 0 factory mode signal 0 -
1 factory mode signal 1 -
2 factory mode signal 2 -
3 factory mode signal 3 -
4 FM1 developing fan rotation detection signal 0: in rotation
5 FM2 fixing fan rotation detection signal 0: in rotation
6 FM4 curl reducing fan 1 rotation detection signal 0: in rotation
7 FM5 curl reducing fan 2 rotation detection signal 0: in rotation
COPIER>I/O>DC-CON