CHAPTER 5 PICK-UP/FEEDING SYSTEM

9.2.2 Removing the Pickup Cover

1)Open the pickup cover [1].

2)Remove the member [2] from the rear.

3)Free the cable [4] from the hook [3].

4)Remove the pickup cover [1].

[2]

[4]

[3][2]

[4]

[1]

F05-902-03

9.2.3 Removing the Multifeeder Tray Pickup Roller

1)Remove the pickup cover. (See item 9.2.2.)

2)Remove the snap-on bushing [1].

3)While taking care not to deform the grounding plate at the rear of the roller shaft [2], shift the roller shaft [2] in the direction of the arrow.

4)Remove the stop ring [3], and detach the multifeeder tray pickup roller [5] while taking care not to drop the paral- lel pin [4] at the rear.

When mounting, be sure that the pin notch (cross-shaped) in the collar [6] of the multifeeder tray pickup roller [5] is toward the rear.

[5]

[6]

 

[2]

[3]

[5]

[4]

[1]

 

 

 

 

 

 

 

 

 

F05-902-04