COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON iR2200/iR2800/iR3300 REV.0 MAR. 2001
CHAPTER 6 FIXING SYSTEM
6-11 P
4 Disassembly and Assembly
The discussions that follow cover the machine’s mechanical characteristics and how to
disassemble/assemble the machine. Keep the following in mind whenever you work with the
machine:
1. The power plug must remain disconnected for safety when disassembling/assembling
the machine.
2. Unless otherwise noted, the machine may be assembled by reversing the steps used to
disassemble it.
3. The screws must be identified by type (length, diameter) and location.
4. The mounting screws used for the grounding wire and the varistors come with a washer,
which must not be left out when assembling the machine.
5. As a rule, the machine must not be operated with any of its parts removed.
6. The door switch or the main power switch must be turned off whenever the duplex
unit or the fixing/feeding unit must be slid out.