Majestic Appliances 43LDVR, 33LDVR Installation & Operating Instructions, Locating Your Fireplace

Page 3

LDVR Series Direct Vent Gas Fireplace

Installation & Operating Instructions

This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances and Equipment. For USA Installations follow local codes and/or the current National Fuel Gas Code. ANSI Z223.1/NFPA 54.

In the Commonwealth of Massachusetts, all gas fitting and installation of this heater shall only be done by a licensed gas fitter or licensed plumber.

FOR SAFE INSTALLATION AND OPERATION PLEASE NOTE THE FOLLOWING:

1.This fireplace gives off high temperatures and should be located out of high traffic areas and away from furniture and draperies.

2.Children and adults should be alerted to the hazards of high surface temperatures of this fireplace and should stay away to avoid burns or ignition of clothing.

3.CAUTION: Due to high glass surface temperature chil- dren should be carefully supervised when in the same room as fireplace.

4.Under no circumstances should this fireplace be modified. Parts removed for servicing should be replaced prior to operating this fireplace again.

5.Installation and any repairs to this fireplace must be performed by a qualified installer, service agency or gas supplier. A professional service person should be contacted to inspect this fireplace annually. Make it a practice to have all of your gas fireplaces checked annually. More frequent cleaning may be required due to excess lint and dust from carpeting, bedding material, etc.

6.Control compartments, burners and air passages in this fireplace should be kept clean and free of dust and lint. Make sure the gas valve and pilot light are turned off before you attempt to clean this fireplace.

7.The venting system (chimney) of this fireplace should be checked at least once a year and if needed your venting system should be cleaned.

8.Keep the area around your fireplace clear of combustible materials, gasoline and other flammable vapor and liquids. This fireplace should not be used as a drying rack for cloth- ing, nor should Christmas stockings or decorations be hung on or around the fireplace.

9.Under no circumstances should any solid fuels (wood, coal, paper or cardboard etc.) be used in this fireplace.

10.The flow of combustion and ventilation air must not be obstructed in any way.

11.When fireplace is installed directly on carpeting, vinyl tile or any combustible material other than wood, the fireplace must be installed on a metal or wood panel extending the full width and depth of the fireplace.

12.This fireplace requires adequate ventilation and combustion air to operate properly.

13.This fireplace must not be connected to a chimney flue serving a separate solid fuel burning fireplace.

14.When the fireplace is not in use it is recommended that the gas valve be left in the OFF position.

15.These units have been approved for bedroom use.

Proposition 65 Warning: Fuels used in gas, wood- burning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm.

California Health & Safety Code Sec. 25249.6

WARNING: Check with your electronics manufacturer before installing a television or other electronic de- vice above this fireplace.

IMPORTANT:

PLEASE REVIEW THE FOLLOWING CAREFULLY

Remove any plastic from trim parts before turning the fireplace ON.

It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine.

It is not unusual for your gas fireplace to give off some odor the first time it is burned. This is due to the curing of the paint and any undetected oil from the manufacturing process.

Please ensure that your room is well ventilated - open all windows.

It is recommended that you burn your fireplace for at least ten (10) hours the first time you use it. If the optional fan kit has been installed, place the fan switch in the “OFF” position during this time.

Locating Your Fireplace

E

A

B

Y

 

 

 

 

C

X

 

 

D

 

 

Y

X

B

 

F

LU584-R

Fig. 1 Locate gas fireplace.

A) Flat on wall

B) Cross corner

C) **Island

D) *Room divider

E) *Flat on wall corner

F) Chase installation

Y) 6” minimum

 

 

NOTE: (fig. 1)

**Island (C) and Room Divider (D) installation is possible as long as the horizontal portion of the vent system (X) does not exceed 20ʼ (610cm). See details in Venting Section.

*When you install your fireplace in(D) Room divider or (E) Flat on wall corner positions (Y), a minimum of 6” (153mm) clear- ance must be maintained from the perpendicular wall and the front side edge of the fireplace.

Refer to (Y) in Figure 1.

10007317

3

Image 3
Contents Installation Instructions Homeownerʼs Manual Table of Contents Installation & Operating Instructions Locating Your FireplacePlease Review the Following Carefully Fireplace Dimensions Framing Dimensions33LDVR 36LDVR 39LDVR 43LDVR Hearth Mantel ChartClearance to Combustibles MantelsGas Inlet and Manifold Pressures Framing and FinishingFinal Finishing Gas SpecificationsInstallation Gas Line InstallationRemote ON/OFF Switch Alternate Switch LocationElectronic Gas Control Valve EB-1 Electrical BoxLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2General Information Assembling Vent Pipes Canadian InstallationsUSA Installations Termination ClearancesExample a How to Use the Vent GraphTwist Lock Pipes Rear Wall Venting ApplicationsStep Rear Wall Installation Twist Lock PipeRear Wall Vent Installations Flex Vent Pipe StepVertical Sidewall Applications Maximum number of 90 elbows is three Zero clearance sleeve is only required for combustible walls Vertical Sidewall InstallationMeasure horizontal length including 2 overlap Below Grade InstallationsVertical Through-the-Roof Applications Snorkel installation, recessed foundationTypical vertical roof applications Vertical Through-the-Roof InstallationMin 610 mm Venting Components Glass Information Glass CleaningWindow Frame Assembly Removal Operating InstructionsInstallation of Logs, Lava Rock & Ember Material Log Identification ChartLog Installation 39LDVR Flame & Temperature Adjustment Flame CharacteristicsRN/RP & EN/EP Models Lighting and Operating Instructions To Turn Off Gas To HeaterWhat to do if YOU Smell GAS Lighting Instructions Turning Off the Gas to the ApplianceValve in the on position Troubleshooting Honeywell Millivolt Valve Start CheckYES Normal Operation Abnormal Operation Troubleshooting the Gas Control SystemSIT 820 Nova Gas Control Valve Fig Fuel Conversion InstructionsSIT top Convertible Pilot PSE PilotBrass Trim MaintenanceCleaning the Standing Pilot Control System Burner and Burner Compartment33/36/39/43LDVR 33LDVR 36LDVR 39LDVR 43LDVR LdvrFuel Conversion Kits DescriptionOptional Accessories Available FK24 Fan AssemblyFan Kits Appliance Model Kit Name Wiring InstructionsRemote Controls Ceramic Refractory KitsFiligree Louvre Kit Optional Trim KitsLouvre Accent Trim Screen Door KitLdvr Series Direct Vent Gas Fireplace Product Covered by this Warranty Limited Lifetime WarrantyAFUE% Efficiency Ratings

33LDVR, 43LDVR, 39LDVR, 36LDVR specifications

Majestic Appliances has established itself as a premier name in the world of luxury appliances, particularly with its line of ranges that includes the 33LDVR, 39LDVR, 43LDVR, and 36LDVR models. Each range is designed to enhance culinary experiences while providing sophisticated aesthetics that blend seamlessly into both modern and traditional kitchens.

The 33LDVR is a compact powerhouse perfect for smaller spaces without compromising on performance. It features dual fuel technology, combining the precision of gas cooking with the consistency of electric ovens. This model is equipped with a 5-burner cooktop, including a high-output burner for achieving quick sears, alongside an innovative simmer burner ideal for delicate sauces. The oven provides a spacious capacity with a convection option, ensuring even baking and roasting every time.

Moving up in size, the 39LDVR offers additional cooking capacity while maintaining the same dual fuel benefits. A standout feature of this model is the built-in griddle, which provides a large flat cooking surface ideal for breakfast foods and stir-frying. The combination of six burners offers a variety of heat options, and an extra-large oven adds flexibility for those who often entertain or prepare multiple dishes simultaneously.

The 43LDVR model is the hallmark of versatility, accommodating serious home chefs who demand the best. This range includes a powerful induction cooktop option, providing rapid heat with precise temperature control. The 43LDVR features a triple oven design, allowing for seamless multitasking during meal preparation. Equipped with advanced smart technology, users can control oven temperatures and settings remotely, making meal prep exceptionally convenient.

Finally, the 36LDVR rounds out the lineup with an impressive balance of size and functionality. With six high-efficiency burners, this model ensures even the most ambitious chefs can cook with precision. Many consider its unique steam oven feature groundbreaking, allowing for healthier cooking options that retain nutrients and enhance flavors.

Collectively, these ranges symbolize Majestic Appliances’ commitment to melding cutting-edge technology with classic design. Each unit is crafted from premium materials, making them not only functional but also visually stunning. Whether it is the user-friendly digital interface, the elegant finishes, or the robust performance, Majestic Appliances continues to push the boundaries of what is possible in home cooking.