Louisville Tin and Stove VC501A, VCR502A, VCR351A, VC351A CHB-3 Blower Installation, Figure B

Page 13

CHB-3 BLOWER INSTALLATION

STEP 1. Run black wire and white wire that comes from bottom of junction box down through the heat shield. See Figure A. STEP 2. Insert junction box into opening in back of heater. Attach using four #8x1/2” black screws provided. See Figure A. STEP 3. Attach fan switch to fan switch bracket using two #8x1/2” plated, Phillip head screws provided. The 2” flange on the

bottom of bracket and terminals on the fan switch should be toward the back of the heater when properly installed. STEP 4. Locate the two engagement holes in base of heater. On a 35,000 Btu heater these holes are approximately 6-1/2” from the

back edge and right and left holes are 5-1/4” and 7-1/4” respectfully from the right side (as viewed from back of heater). On a 50,000 Btu heater the holes are approximately 10-3/4” from the back edge and right and left holes are 5-3/8” and 7-3/8” respectfully from the right side. Attach fan switch bracket to base using two #8x1/2” hex head screws provided. This will require a ¼” socket and ratchet. See Figure A.

STEP 5. Locate the blower opening and mounting tab on the base of the heater. Insert the front flange of the blower housing under the mounting tab, lower the back of the blower down onto the base aligning the clearance holes in the blower base with the engagement holes in the heater base. Secure the blower to the base with two #8 screws provided. See figure A.

STEP 6. Connect black wire from junction box to right fan switch terminal. See Figure B. STEP 7. Connect white wire from junction box to white fan motor wire. See Figure B. STEP 8. Connect black wire from fan motor to left fan switch terminal. See Figure B.

STEP 9. Turn variable speed control switch clockwise (as viewed from front of unit) to “OFF”. STEP 10. Plug power cord into 115 V. grounded receptacle.

STEP 11. Turn variable speed control switch counterclockwise (as viewed from front of unit) from “OFF” to “HIGH”. Blower will now cycle on automatically when the switch temperature is met after the main burner comes on. The blower will continue to run for a short period after the main burner goes off. Blower speed can be adjusted by setting the variable speed control switch between high and low.

WARNING: This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

Heat Shield

 

 

 

Junction

 

 

BLACK

Box

 

 

WHITE

 

 

Control

 

 

Speed

 

 

FAN

 

 

 

 

 

MOTOR

SWITCH

Power

 

 

WHITE

Cord

 

 

GREEN

 

 

BLACK

 

 

 

Fan Switch

 

 

MOTOR SPEED

Bracket

 

 

 

 

CONTROL

 

 

 

Blower

 

 

“If any part of the original wire as suppied

Housing

 

 

 

 

 

with the appliance must be replaced, it

 

 

 

must be replaced with a wire of at least

 

 

 

a 105 degree C temperature rating.”

Mounting Tab

 

 

 

 

 

 

FIGURE B

FIGURE A

 

 

 

 

Page 13

Image 13
Contents Natural GAS This Unit is not to be Installed in Mobile HomesVCR351A VCR501A VCR701A Propane GAS VCR352A VCR502A VCR702ARead Carefully Before Installing Unit Table of ContentsRoom Heater Specifications Specifications Type Control GAS Model NumbersVenting IntroductionPossible Causes Corrective Action Unsafe Recommended Connecting the Vent Into AN Existing ChimneyGAS Supply Location and Speical PrecautionsUL Listed Vent Cap UL Listed Gas Vent Opening Combustion and Ventilation AIRDoor Knob Draft DiverterClearances Pilot Flame Adjust Pilot AdjustmentMent Radiants and Glass PanelsCleaning of Combustion Chamber MaintenanceWhat to do if YOU Smell GAS For Your Safety Read Before LightingSymptom Possible Causes Corrective Action Trouble Shooting Chart for qualified serviceman Main BurnerTrouble Shooting Chart Automatic Pilot & Valve CHB-3 Blower Installation REV /01 Models IncludedNAT Your GAS Control and Pilot Light System Critical Safety Points to RememberTampering is Dangerous If YOU Smell GAS, DON’T Light ITLimited Warranty

VC352A, VC202A, VC502A, VC701A, VCR501A specifications

The Louisville Tin and Stove line of products, featuring models like the VC501A, VC201A, VC351A, VCR701A, and VC352A, presents a comprehensive range of high-performance heating solutions designed for efficiency, durability, and user comfort. Each model is tailored to meet diverse needs, from residential heating to more specialized applications, while maintaining a commitment to quality and innovation.

Starting with the VC501A, this model is particularly noted for its impressive heating capacity, making it suitable for larger spaces. It incorporates advanced combustion technologies that maximize fuel efficiency, ensuring longer burn times and reduced emissions. Users can enjoy customizable temperature settings, enhancing comfort in any environment.

The VC201A model offers a compact design, optimized for smaller areas without compromising on performance. Its straightforward controls allow for easy operation, making it ideal for those looking to heat a single room or supplement their main heating system. The sleek design ensures that it seamlessly fits into various home decors while maintaining effective heating capabilities.

Moving to the VC351A, this model is distinguished by its dual-fuel capability, allowing users to switch between propane and natural gas. This flexibility not only caters to different user preferences but also enhances reliability, particularly during power outages. The generous viewing window provided by this model adds an aesthetic touch while allowing users to enjoy the ambiance of the flames.

The VCR701A stands out with its robust build quality, designed to withstand rugged conditions. This model is ideal for those who require a heater that can function efficiently in more demanding environments, such as workshops or garages. Its high-efficiency technology minimizes energy consumption while delivering substantial heat output, making it both economical and effective.

Finally, the VC352A rounds out the lineup with its advanced safety features. This model includes an automatic shut-off mechanism that engages in case of overheating or fuel supply interruption, giving users peace of mind. Additionally, its environmentally friendly design meets the latest emissions standards, making it a responsible choice for conscientious consumers.

In summary, the Louisville Tin and Stove models VC501A, VC201A, VC351A, VCR701A, and VC352A bring together innovative technologies, user-focused designs, and reliable performance. Whether for home, workshop, or specialty applications, these models cater to various heating demands, providing warmth, comfort, and safety to users.