Louisville Tin and Stove VCR352A, VCR502A, VCR351A GAS Supply, Location and Speical Precautions

Page 5

GAS SUPPLY

This vented room heater must be connected to a gas supply capable of supplying the appliances full rated capacity. Provide a 1/8 inch N.P.T. plugged tapping, accessible for test gauge connection, immediately upstream of the gas supply connection to the appliance. The minimum inlet pressure in the gas supply pipe should be 4.5” w.c. for Natural Gas and 11.0” w.c. for Propane Gas, “for the purpose of input adjustment”. The maximum inlet pressure in the gas supply pipe should never exceed 14” w.c. for either Natural or Propane Gas. The gas supply piping should be sized in accordance with ANSI Z223.1 National Fuel Gas Code. The normal manifold pressure should be 3.5” w.c. for Natural Gas and 10.0” w.c. for Propane Gas.

If the outlet pressure of the gas valve must be adjusted, this should be done by a qualified serviceman using proper tools and instruments.

Check all connections with soapy water for possible gas leaks. Never use a match, candle or other ignition source. It is recommended that pipe compound which is resistant to the action of liquefied petroleum gases be used. Do not use Teflon tape or Teflon impregnated compound.

The appliance and its individual shutoff valve must be disconnected from the gas supply piping during any pressure testing of that system at the test pressure in excess of ½ psig.

The appliance must be isolated from the gas supply piping by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psig.

LOCATION AND SPEICAL PRECAUTIONS

Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies.

Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition.

Young children should be carefully supervised when they are in the same room as the appliance.

Clothing or other flammable material should not be placed on or near the appliance.

Any safety screen, guard, or casing top removed for servicing a room heater must be replaced prior to operating the appliance.

Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water.

For purpose of identifying the sides of the heater. When you are facing the front of the heater the right side has the access door and the left side is solid.

If heater is installed in a residential garage, all burners and pilot must be above 18”. Locate or protect heater so it cannot be damaged by a moving vehicle.

Page 5

Image 5
Contents Natural GAS This Unit is not to be Installed in Mobile HomesVCR351A VCR501A VCR701A Propane GAS VCR352A VCR502A VCR702ARead Carefully Before Installing Unit Table of ContentsRoom Heater Specifications Specifications Type Control GAS Model NumbersPossible Causes Corrective Action IntroductionVenting Unsafe Recommended Connecting the Vent Into AN Existing ChimneyGAS Supply Location and Speical PrecautionsUL Listed Vent Cap UL Listed Gas Vent Opening Combustion and Ventilation AIRClearances Draft DiverterDoor Knob Pilot Flame Adjust Pilot AdjustmentMent Radiants and Glass PanelsCleaning of Combustion Chamber MaintenanceWhat to do if YOU Smell GAS For Your Safety Read Before LightingSymptom Possible Causes Corrective Action Trouble Shooting Chart for qualified serviceman Main BurnerTrouble Shooting Chart Automatic Pilot & Valve CHB-3 Blower Installation REV /01 Models IncludedNAT Your GAS Control and Pilot Light System Critical Safety Points to RememberTampering is Dangerous If YOU Smell GAS, DON’T Light ITLimited Warranty

VC352A, VC202A, VC502A, VC701A, VCR501A specifications

The Louisville Tin and Stove line of products, featuring models like the VC501A, VC201A, VC351A, VCR701A, and VC352A, presents a comprehensive range of high-performance heating solutions designed for efficiency, durability, and user comfort. Each model is tailored to meet diverse needs, from residential heating to more specialized applications, while maintaining a commitment to quality and innovation.

Starting with the VC501A, this model is particularly noted for its impressive heating capacity, making it suitable for larger spaces. It incorporates advanced combustion technologies that maximize fuel efficiency, ensuring longer burn times and reduced emissions. Users can enjoy customizable temperature settings, enhancing comfort in any environment.

The VC201A model offers a compact design, optimized for smaller areas without compromising on performance. Its straightforward controls allow for easy operation, making it ideal for those looking to heat a single room or supplement their main heating system. The sleek design ensures that it seamlessly fits into various home decors while maintaining effective heating capabilities.

Moving to the VC351A, this model is distinguished by its dual-fuel capability, allowing users to switch between propane and natural gas. This flexibility not only caters to different user preferences but also enhances reliability, particularly during power outages. The generous viewing window provided by this model adds an aesthetic touch while allowing users to enjoy the ambiance of the flames.

The VCR701A stands out with its robust build quality, designed to withstand rugged conditions. This model is ideal for those who require a heater that can function efficiently in more demanding environments, such as workshops or garages. Its high-efficiency technology minimizes energy consumption while delivering substantial heat output, making it both economical and effective.

Finally, the VC352A rounds out the lineup with its advanced safety features. This model includes an automatic shut-off mechanism that engages in case of overheating or fuel supply interruption, giving users peace of mind. Additionally, its environmentally friendly design meets the latest emissions standards, making it a responsible choice for conscientious consumers.

In summary, the Louisville Tin and Stove models VC501A, VC201A, VC351A, VCR701A, and VC352A bring together innovative technologies, user-focused designs, and reliable performance. Whether for home, workshop, or specialty applications, these models cater to various heating demands, providing warmth, comfort, and safety to users.