Fujitsu R410A operation manual Self-Diagnosis, Temperature and Humidity Range

Page 15

OPERATING TIPS

Notice

*• During use of the heating mode, the outdoor unit will occasionally commence the defrost operation for brief periods. During the defrosting operation, if the user sets the indoor unit for heating again, the defrosting mode will continue, and the heating operation will begin after completion of defrosting, with the result that some time may be required before warm air is emitted.

*• During use of the heating mode, the top of the indoor unit may become warm, but this is due to the fact that coolant is circulated through the indoor unit even when it is stopped; it is not a malfunction.

SELF-DIAGNOSIS

When “EE” in Temperature Display is displayed, inspection of the air conditioning system is necessary. Please consult authorized service personnel.

Unit number (usually 00)

Error code

SU MO TU WE TH FR SA

ex. Self-diagnosis check

TEMPERATURE AND HUMIDITY RANGE

Permissible ranges of temperature and humidity are as follows:

Cooling / Dry

Outdoor temperature

About –15°C to 46°C

Operation

 

 

Indoor temperature

About 18°C to 32°C

 

 

 

 

 

Indoor humidity

Below approximately 80%.

 

 

If the air conditioner is used continuously for many hours,

 

 

water may condense on the surface and drip.

 

 

 

Heating

Outdoor temperature

About –15°C to 24°C

 

 

 

 

Indoor temperature

About 16°C to 30°C

 

 

 

If the unit is used under higher temperature conditions than those noted here, the automatic protection circuit may operate, interrupting the operation.

If the unit is used under lower temperature conditions than those noted here, the heat exchanger may freeze, causing water leakage or other malfunction.

Do not use the air conditioner for any purpose other than room cooling/dry, room heating, or fan.

14

Image 15
Contents Operating Manual Safety Precautions ContentsName of Parts Remote controllerSet the current day and time Preparatory OperationTo set the operation mode OperationTo start/stop operation Child lock function Room temperature sensor selectionON/OFF Timer Timer FunctionsWeekly timer setting Day of the week settingTime setting To set the DAY OFF for a holiday Weekly TimerWeekly timer operation Normal Next day settingDay setting Operating time setting Temperature SET Back TimerTemperature SET Back timer setting Temperature SET Back timer operationCleaning and Care TroubleshootingCleaning the Air Filter Check Once Operating Tips Auto Restart Mode operation AutoAbout Mode Operation Event of Power InterruptionSELF-DIAGNOSIS Temperature and Humidity RangeFujitsu General Limited

R410A specifications

Fujitsu R410A is a state-of-the-art refrigerant commonly used in air conditioning systems and heat pumps. Recognized for its superior thermal efficiency and environmental considerations, R410A has become a popular choice among manufacturers and consumers alike.

One of the standout features of Fujitsu R410A is its high energy efficiency. This refrigerant operates on a higher pressure than traditional refrigerants like R22, which allows for better heat exchange and thus improves the overall performance of HVAC units. The efficiency is evident in both cooling and heating capacities, which contributes to reduced energy costs for end users. As energy efficiency becomes increasingly important, R410A meets the demands of modern consumers looking for sustainable solutions without sacrificing comfort.

Fujitsu incorporates advanced technologies in their R410A systems to enhance performance further. The variable speed inverter technology found in many Fujitsu air conditioning systems allows for more precise temperature control and improved efficiency. By adjusting the compressor speed according to the cooling or heating demand, these systems can operate at a lower capacity when required, reducing energy consumption and maintaining indoor comfort more effectively.

Another characteristic of Fujitsu R410A is its low global warming potential (GWP). While traditional refrigerants have raised concerns about their impact on climate change, R410A has a significantly lower GWP, making it a more environmentally friendly option. The use of R410A helps meet international regulations aimed at reducing greenhouse gas emissions, positioning it as a sustainable choice in the HVAC industry.

Additionally, Fujitsu units utilizing R410A are known for their quiet operation. Advances in design and engineering minimize noise levels, contributing to a more pleasant indoor environment. Noise-reduction technologies, combined with efficient airflow management, ensure that users can enjoy comfort without disruptive sounds.

Furthermore, Fujitsu provides robust support and maintenance services for R410A systems, ensuring optimal performance over their lifespan. Their commitment to reliability is reflected in the build quality and design of the units, which are engineered for longevity and dependability.

In summary, Fujitsu R410A is a premium refrigerant characterized by high energy efficiency, advanced inverter technology, low global warming potential, and quiet operation. These features make it a preferred choice for modern air conditioning and heating solutions, affirming Fujitsu's commitment to innovation in the HVAC industry while prioritizing environmental responsibility.