Fujitsu AOU15RLQ Operating Tips, Operation and Performance, Auto Restart, Heating Performance

Page 19

TROUBLESHOOTING

 

Symptom

Items to check

See Page

 

 

 

 

CHECK ONCE

Doesn’t operate at all:

● Is the Power Supply Plug disconnected its outlet?

 

MORE

 

● Has there been a power failure?

 

 

● Has a fuse blown out, or a circuit breaker been tripped?

 

 

 

 

 

 

 

● Is the timer operating?

8 - 9

 

 

 

 

 

Poor Cooling performance:

● Is the Air Filter dirty?

 

 

 

● Air the air conditioner’s intake grille or outlet port blocked?

 

 

 

● Did you adjust the room temperature settings (thermostat) cor-

 

 

 

rectly?

 

 

 

● Is there a window or door open?

 

 

● In the case of Cooling operation, is a window allowing bright sun-

 

 

 

light to enter? (Close the curtains.)

 

 

 

● In the case of Cooling operation, are there heating apparatus and

 

 

 

computers inside the room, or are there too many people in the

 

 

 

room?

 

 

 

 

 

 

 

● Is the unit set for SUPER QUIET operation?

5

 

 

 

 

 

The unit operates

● Are the Remote Control Unit’s batteries dead?

 

 

differently from the Remote

● Are the Remote Control Unit’s batteries loaded properly?

4

 

Control Unit’s setting:

 

 

 

 

 

 

If the problem persists after performing these checks, or if you notice burning smells, or the OPERATION Indicator Lamp (Fig. 3 5) and the TIMER Indicator Lamp (Fig. 3 6) flashes, immediately stop operation, disconnect the Power Supply Plug (Fig. 1 F), and consult authorized service personnel.

OPERATING TIPS

Operation and Performance

Heating Performance

Microcomputer-controlled Automatic Defrosting

This air conditioner operates on the heat-pump princi- ple, absorbing heat from outdoor air and transferring that heat indoors. As a result, the operating performance is reduced as outdoor air temperature drops. If you feel that insufficient heating performance is being produced, we recommend you use this air conditioner in conjunction with another kind of heating appliance.

Heat-pump air conditioners heat your entire room by recirculating air throughout the room, with the result that some time may be required after first starting the air con- ditioner until the room is heated.

When using the Heating mode under conditions of low outdoor temperature and high humidity, frost may form on the outdoor unit, resulting in reduced operating per- formance.

In order to prevent this kind of reduced performance, this unit is equipped with a Microcomputer-controlled Auto- matic Defrosting function. If frost forms, the air condi- tioner will temporarily stop, and the defrosting circuit will operate briefly (for about 7-15 minutes).

During Automatic Defrosting operation, the OPERATION Indicator Lamp (red) will flash.

AUTO Restart

In Event of Power Interruption

The air conditioner power has been interrupted by a power failure. The air conditioner will then restart auto- matically in its previous mode when the power is restored.

Operated by setting before the power failure.

If a power failure occurs during TIMER operation, the timer will be reset and the unit will begin (or stop) operation at the new time setting. In the event that this kind of timer fault occurs the TIMER Indicator Lamp will flash (see Page. 3).

Use of other electrical appliances (electric shaver, etc.) or nearby use of a wireless radio transmitter may cause the air conditioner to malfunction. In this event, temporarily disconnect the Power Supply Plug, reconnect it, and then use the Remote Control Unit to resume operation.

En-17

Image 19
Contents Español Français English Operating ManualTo facilitate explanation, the accompanying illustra Safety Precautions ContentsInverter Features and FunctionsIndoor Unit Operating Control Panel Fig Manual Auto button Name of PartsPreparation Operation To Stop Operation Press the START/STOP button N About Mode OperationAbout Auto Changeover Operation Air cleaning AIR Cleaning OperationPress the AIR Clean button O If you wish to stop Air CleanTimer Operation During Cooling/Dry operation Sleep Timer OperationAbout the Sleep Timer During Heating operationTypes of Air flow Direction Setting Adjusting the Direction of AIR CirculationVertical Air Direction Adjustment Press the SET button Q Right-Left Adjustment Adjust the Right-Left louversTo select Swing Operation Press the Swing button T Swing OperationCoil DRY Operation Manual Auto OperationCleaning and Care Wash with water and dry Cleaning the Plasma AIR Cleaning FilterRegarding the Air Cleaning check function Remove the dust collection unitInstall the air filter Install the unitClose the intake grille Remove the dust-collecting unit Install the dust-collection unitInstall the Air-cleaning and Deodorizing filter Install the air filter and close the intake grilleSymptom Problem TroubleshootingAuto Restart Event of Power InterruptionOperating Tips Operation and PerformanceTips for saving energy Temperature and Humidity RangeCooling Mode Dry Mode Heating Mode Outdoor temperature Indoor temperature About 64 F to 90 F Or less

AOU18RLQ, AOU15RLQ, ASU18RLQ, ASU15RLQ specifications

Fujitsu is a prominent name in the HVAC industry, known for its innovative air conditioning solutions that combine efficiency, comfort, and advanced technologies. Among its popular models are the AOU15RLQ, AOU18RLQ, ASU15RLQ, and ASU18RLQ. These units are designed to meet diverse cooling and heating needs for residential and commercial spaces.

The AOU15RLQ and AOU18RLQ are outdoor units that serve as the backbone of Fujitsu's multi-split air conditioning systems. One of their main features is their ENERGY STAR certification, which ensures superior energy efficiency. Both models incorporate inverter technology, allowing them to adjust their cooling and heating output based on the current demand. This leads to reduced energy consumption and increased comfort.

Moreover, these outdoor units operate quietly, providing a peaceful environment for users. They are designed with a compact footprint, making them suitable for various installation locations. The AOU series also supports multi-zone configurations, allowing homeowners to control different areas of their space independently, thereby enhancing comfort and efficiency.

On the other hand, the ASU15RLQ and ASU18RLQ are the corresponding indoor units that work seamlessly with their outdoor counterparts. These models feature a sleek design that can effortlessly blend into any décor. They utilize advanced air filtration systems that capture dust, allergens, and other pollutants, promoting indoor air quality.

Both indoor models offer multiple fan speeds and adjustable airflow direction, ensuring optimal distribution of conditioned air. The ASU series is equipped with user-friendly remote controls and includes programmable timers, allowing for customizable operation that aligns with users' schedules.

Fujitsu has also integrated smart technology into these units. The models can be connected to Wi-Fi, enabling users to control their air conditioning systems remotely through their smartphones. This integration facilitates monitoring and adjusting settings from anywhere, enhancing convenience.

In summary, the Fujitsu AOU15RLQ, AOU18RLQ, ASU15RLQ, and ASU18RLQ represent a harmonious blend of innovation and efficiency. With their advanced inverter technology, energy-saving features, and smart connectivity, these air conditioning systems are well-suited for modern homes looking for reliable and effective climate control solutions. Whether for residential use or light commercial applications, these models cater to a broad spectrum of comfort needs, ensuring a pleasant indoor environment year-round.