Fujitsu AIR CONDITIONER, 9319356051 manuel dutilisation Troubleshooting, Symptom Problem

Page 22

TROUBLESHOOTING

WARNING

In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical

breaker and consult authorized service personnel.

 

 

Merely turning off the unit’s power switch will not completely disconnect the unit from the power source.

 

Always be sure to turn off the electrical breaker to ensure that power is completely off.

Before requesting service, perform the following checks:

 

Symptom

Problem

See Page

 

 

 

 

NORMAL

Doesn’t operate

● If the indoor unit is stopped and then immediately started again, the

 

FUNCTION

immediately:

compressor will not operate for about 3 minutes, in order to prevent

 

 

 

fuse blowouts.

 

 

● Whenever the electrical breaker is turned off then on again the pro-

 

 

 

tection circuit will operate for about 3 minutes, preventing unit opera-

 

 

 

tion during that period.

 

 

 

 

 

 

Noise is heard:

● During operation or immediately after stopping the unit, the sound of

 

 

 

water flowing in the air conditioner’s piping may be heard. Also, noise

 

 

 

may be particularly noticeable for about 2 to 3 minutes after starting

 

 

operation (sound of refrigerant flowing).

 

 

● During operation, a slight squeaking sound may be heard. This is the

 

 

 

result of minute expansion and contraction of the front panel due to

 

 

 

temperature changes.

 

 

 

 

 

 

 

● During Heating operation, a sizzling sound may be heard occasional.

23

 

 

This sound is produced by the Automatic Defrosting operation.

 

 

 

 

 

 

 

 

Smells:

● Some smell may be emitted from the indoor unit. This smell is the re-

 

 

sult of room smells (furniture, tobacco, etc.) which have been taken

 

 

into the indoor unit.

 

 

 

 

 

 

Mist or steam is emitted:

● During Cooling or Dry operation, a thin mist may be seen emitted

 

 

 

from the indoor unit. This results from the sudden Cooling of room air

 

 

by the cool air emitted from the indoor unit, resulting in condensation

 

 

 

 

 

and misting.

 

 

 

 

 

 

 

● During Heating operation, the outdoor unit’s fan may stop, and steam

23

 

 

may be seen rising from the unit. This is due to Automatic Defrosting

 

 

operation.

 

 

 

 

 

 

Airflow is weak or stops:

● When Heating operation is started, fan speed is temporarily very low,

 

 

 

to allow internal parts to warm up.

 

 

 

● During Heating operation, if the room temperature rises above the

 

 

temperature setting, the outdoor unit will stop, and the indoor unit will

 

 

 

 

 

operate at very low fan speed. If you wish to warm the room further,

 

 

 

set the temperature for a higher setting.

 

 

 

 

 

 

 

● During Heating operation, the indoor unit will temporarily stop opera-

 

 

 

tion (Max.15 minutes) as the Automatic Defrosting mode operates.

23

 

 

During Automatic Defrosting operation, the OPERATION Indicator

 

 

 

 

 

Lamp will flash.

 

 

 

 

 

 

 

● During Dry mode, the indoor unit will operate at low speed; in order

 

 

 

to adjust room humidity, the indoor unit’s fan may stop from time to

8

 

 

time. Also, the fan may operate at very low speed when adjusting

 

 

 

 

 

room humidity.

 

 

 

 

 

 

 

● During SUPER QUIET operation, the fan will operate at very low speed.

7

 

 

 

 

 

 

● In the monitor of AUTO operation, the fan will operate at very low

8

 

 

speed.

 

 

 

 

 

 

 

 

Water is produced from

● During Heating operation, water may be produced from the outdoor

23

 

the outdoor unit:

unit due to Automatic Defrosting operation.

 

 

 

 

 

 

En-22

Image 22
Contents Operating Manual Mode D’EMPLOI Manual DE Funcionamiento Contents Safety PrecautionsFeatures and Functions Name of Parts FAN speed indicator Swing indicator Preparation Operation To Stop Operation Press the START/STOP button About Mode OperationAbout Auto Changeover Operation Adjusting the Direction of AIR Circulation Swing OperationEnergy Saving Program To enable the Energy SavingTo disable the Energy Saving Press the Sensor buttonTo stop Powerful Operation Press the Powerful button Powerful OperationTo use Powerful Operation Press the Powerful button Economy OperationTo use MIN. Heat Operation Press the MIN. Heat button Outdoor Unit LOW Noise OperationManual Auto Operation To stop MIN. Heat Operation Press the START/STOP buttonON/OFF Timer Operation Will be flashing, so pressTo select Program Timer OperationPress the Next button Press the Select button Press the Select button To set the desired on timeAbout the Sleep timer Sleep Timer OperationTo use the Sleep timer Press the Timer Setting button Will be firstly displayed flashingUsing in these cases of Weekly timer Weekly Timer OperationNo timer settings Select the program and the day using the Select button Using the Select buttonOn Timer, OFF Timer, or without a timer Select operation withTime or OFF time To set the temperaturePress the Select button To return to Cleaning and Care Filter Indicator Reset The special setting Install the air filters and close the intake grilleAbout the Air Cleaning Filters Troubleshooting Symptom ProblemOperation and Performance Event of Power InterruptionOperating Tips Auto Restart

9319356051, AIR CONDITIONER specifications

The Fujitsu 9319356051 air conditioner stands out as a robust solution for both residential and commercial cooling needs, offering a blend of efficiency, design, and advanced technology. One of the most notable features of this air conditioning unit is its exceptional energy efficiency. It leverages advanced inverter technology, allowing the compressor to adjust its speed according to the cooling demand. This not only maintains a consistent temperature but also significantly reduces energy consumption, making it an eco-friendly option.

Equipped with a powerful cooling capacity, the Fujitsu 9319356051 is designed to effectively cool large spaces. Its rapid cooling feature ensures that the environment reaches the desired temperature quickly, providing comfort when it is needed the most. This air conditioner also incorporates a dehumidification function, which effectively reduces humidity levels, enhancing overall comfort without the excessive coolness that often accompanies high-capacity cooling units.

One of the defining characteristics of the Fujitsu 9319356051 is its quiet operation. The noise levels produced during operation are minimal, allowing users to enjoy a peaceful environment, whether it’s during day or night. This feature makes it particularly suitable for bedrooms, offices, and other quiet spaces where noise could be a distraction.

In terms of user control, the air conditioner boasts an intuitive remote control and programmable settings. Users can set timers, adjust temperatures, and choose from various modes—cooling, heating, and fan modes—ensuring that the unit meets diverse climate control needs. The ability to save preferred settings adds to the convenience, allowing for personalized comfort at the touch of a button.

The design of the Fujitsu 9319356051 is both functional and aesthetically pleasing, designed to blend seamlessly with various room decors. Its compact size allows for flexible installation options, whether mounted on a wall or set up in a window.

Overall, the Fujitsu 9319356051 air conditioner combines energy efficiency, powerful cooling, quiet operation, and user-friendly features, making it an excellent choice for those looking for a reliable and high-performing air conditioning unit. With its emphasis on comfort and efficiency, it continues to be a popular choice among consumers seeking quality climate control solutions.