Fujitsu 9368987046, AIR CONDITIONER CASSETTE TYPE manual Operating Tips

Page 10

OPERATING TIPS

Instructions relating to heating are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

Mode operation: AUTO

COOLING MODEL

When the room temperature is 4 °F higher than the set temperature, the mode will switch between Cooling and Drying.

During the Drying mode operation, the FAN setting should be switched to LOW for a gently cooling effect during which the fan may temporarily stop rotating.

HEAT & COOL MODEL (Reverse Cycle)

Auto changeover function

• When AUTO CHANGEOVER is selected, the air conditioner

selects the appropriate operation mode (Cooling or Heat-

ing) according to your room’s present temperature.

• When AUTO CHANGEOVER is first selected, the fan will

operate at a very low speed for about 1 minute while the

unit determines the current conditions of the room and

selects the proper operation mode.

• When the room temperature is near the thermostat set-

Energy save

The energy conservation mode (ENERGY SAVE) raises the set temperature slightly in the cooling mode and lowers the set temperature in the heating mode to economically control the operation of the unit.

If you press the ENERGY SAVE button while the unit is in the timer mode, the unit will go into the conservation mode when the unit starts with the timer.

If you turn off the air conditioner while in the conservation mode, the mode will be shut off.

The temperature set on the remote controller will not change if the energy save mode is used.

During cooling operation

82°F

When the ENERGY SAVE is

 

pressed, the thermostat setting

80°F

is automatically rised 2 °F every

60 min.

60 minutes, until the thermostat

 

is rised a total of 4 °F.

78°F

ting, the air conditioner will begin monitor operation. In

the monitor operation mode, the fan will operate at a very

low speed. If the room temperature subsequently changes,

the air conditioner will once again select the appropriate

operation (Heating or Cooling) to adjust the temperature

to the value set in the thermostat. (The monitor operation

range is ±4 °F relative to the thermostat setting.)

Fan speed: AUTO

During heating operation

When the ENERGY SAVE is pressed, the thermostat setting is automatically lowered 2 °F every 30 minutes, until the ther- mostat is lowered a total of 4 °F.

Energy save

74°F

72°F

70°F

30 min.

68°F

30 min.

66°F

30 min.

Energy save

Heating: The fan will operate at very low speed when the tem- perature of the air issued from the indoor unit is low.

Cooling: As the room temperature approaches that of the set temperature, the fan speed becomes slower.

Fan: The fan alternately turns on and off; when on, the fan runs at the low fan speed.

AUTO restart

Should the power supply to the air conditioner be inter- rupted by a power failure, the air conditioner will restart automatically in the previously selected mode once the power is restored.

Use of other electrical appliances (electric shaver, etc.) or nearby use of a wireless radio transmitter may cause the air conditioner to malfunction. In this event, temporarily turn off the circuit breaker turn it on again and then use the remote controller to resume operation.

Heating performance

This air conditioner operates on the heat-pump principle, absorbing heat from outdoor air and transferring that heat indoors. As a result, the operating performance is reduced as outdoor air temperature drops. If you feel that insuffi- cient heating performance is being produced, we recom- mend you use this air conditioner in conjunction with an- other kind of heating appliance.

Heat-pump air conditioners heat your entire room by recirculating air throughout the room, with the result that some time may be required after first starting the air con- ditioner until the room is heated.

Hot start (for heating)

The indoor unit prevents cold drafts when heating operation begins.

The indoor unit fan will not operate or it will operate at a very low speed until the heat exchanger reaches the set tempera- ture.

Defrosting (for heating)

When the outdoor temperature is low and the humidity high, frost will collect on the outdoor unit, reducing heater efficiency. When this happens, the computer will automatically start the defrost cycle. During the defrost cycle, the indoor fan will shut-

down and will be displayed on the remote controller. It will take anywhere from 4 to 15 minutes before the air condi- tioner starts up again.

Group Control

One remote controller can control up to 16 air conditioners. All of the air conditioners will be operated with the same set- tings.

Dual Remote Controllers (optional)

An additional remove controller can be added up to the maxi- mum of two remote controllers. Either remote controller can control the air conditioner. However, the timer functions can- not be used at the slave unit.

En-9

Image 10
Contents Cassette Type Contents Safety PrecautionsRemote controller Name of PartsOperation To set the operation modePreparatory Operation Set the current day and timeEnergy save Room temperature sensor selectionPart lock function To set the ON/OFF timer Timer FunctionsON/OFF Timer To cancelDay of the week setting Weekly timer settingTime setting Normal Next day setting Weekly TimerWeekly timer operation To set the DAY OFF for a holidayTemperature SET Back timer operation Temperature SET Back TimerTemperature SET Back timer setting Day setting Operating time settingOperating Tips Multi-type Air conditioner Simultaneous Use of Multiple UnitsAirflow direction setting Range of swing Adjusting the Direction of AIR CirculationTo adjust the vertical airflow direction Swing OperationCare and Maintenance Cleaning the air filterHow to cleaning SELF-DIAGNOSISTroubleshooting Symptom ProblemSymptom Items to check More