Holmes HASF1796RC warranty Assembly Instructions, Base / Pole Assembly, Fan Head Assembly

Page 2

PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS

When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:

1)

Read all instructions before using the appliance.

2)

To avoid fire or shock hazard, plug the appliance directly into a 120 V AC

 

electrical outlet.

3)

Keep the cord out of heavy traffic areas. DO NOT let the cord hang over

 

the edge of a table or counter. To avoid fire hazard, NEVER put the cord

 

under rugs, near heat registers, radiator, stoves, or heaters.

4)

To protect against electrical hazards, DO NOT immerse in water or other

 

liquids. Do not use near water.

5)

Close supervision is necessary when any appliance is used by or near

 

children, or by disabled people.

6)

Always unplug the fan before moving it, putting on or taking off parts,

 

cleaning, or whenever the fan is not in use. Be sure to pull by the plug

 

and not the cord.

7)

Avoid contact with moving parts. DO NOT operate without fan grills prop-

 

erly in place.

8)

DO NOT operate any appliance with a damaged cord or plug, if motor fan

 

fails to rotate, after the appliance malfunctions, or if it has been dropped

 

or damaged in any manner. Return appliance to manufacturer for

 

examination, electrical or mechanical adjustment, or repair.

9)

DO NOT operate in the presence of explosive and/or flammable fumes.

10)

Use appliance only for intended household use as described in this

 

manual. Any other use not recommended by the manufacturer may

 

cause fire, electric shock, or injury to persons. The use of attachments not

 

recommended or sold by The Holmes Group may cause hazards.

11)

DO NOT use outdoors.

ASSEMBLY INSTRUCTIONS

Base / Pole Assembly

Step 1: Push in the small tab on each foot extension and snap into base

Step 2: Remove the base collar from the base by turning counter-clockwise.

Step 3: Take the pole, with the solid end down, and insert it into the base. The hollow end of the pole (with the screw hole) will be facing up.

Step 4: Replace the height adjustment knob over the pole, slide it down

the pole, and secure it to the base by turning clockwise.

Fan Head Assembly

Step 1: Position the rear grill over the motor shaft, making certain the 2 notches at the top and bottom of the rear grill fit over the 2 prongs on the motor housing. Please make sure the rear grill fits securely against the motor housing.

Step 2: Secure the rear grill in its place using the rear grill mounting- ring. Turn this ring clockwise and tighten firmly.

Step 3: Slide the fan blade; with the hollowed interior of the blade fac- ing towards the rear grill firmly onto the motor shaft. Make sure the shaft protrudes from the front of the blade.

Step 4: Secure the fan blade onto the motor shaft by turning the fan blade cap in a counter-clockwise direction until it is firmly in place.

Step 5: Prepare the front grill by simply snapping the circular front grill logo plate in place.

Step 6: Center the front grill by aligning the Holmes logo so it is hori- zontal and parallel to the floor. Place the front grill on to the rear grill and snap into place. Tighten the securing screw at the bottom of the front grill.

12)

Always use on a dry, level surface.

13)

Keep unit away from heated surfaces and open flames.

14)

WARNING: To reduce the risk of fire or electric shock, DO NOT use this fan

 

with any solid-state speed control device.

15)

DO NOT attempt to repair or adjust any electrical or mechanical functions

 

on this unit. Doing so will void your warranty. The inside of the unit con-

 

tains no user serviceable parts. All servicing should be performed by

 

qualified personnel only.

PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS

THIS PRODUCT IS EQUIPPED WITH A POLARIZED AC (Alternating Current) PLUG (a plug having one blade wider than the other). This plug will fit into the power outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact qualified personnel to install the proper outlet.

DO NOT DEFEAT THE SAFETY PURPOSE OF THIS

POLARIZED PLUG IN ANY WAY

A

B

C

D

 

 

A.LOGO PLATE

B.FRONT GRILL

C.FAN BLADE CAP

D.FAN BLADE

E.REAR-GRILL MOUNTING RING

F.REAR GRILL

G.MOTOR SHAFT

H.MOTOR HOUSING

I.OSCILLATION KNOB

J.NECK

K.TILT-ADJUSTMENT KNOB

L.1TOUCHFRONT HOUSING

M.1TOUCHREAR HOUSING

N.THUMBSCEW

O.POLE

P.HEIGHT ADJUSTMENT KNOB

 

 

G

H

 

 

I

 

 

 

 

 

 

J

 

 

 

K

E

 

 

N

 

 

 

U

F

 

M

 

L

 

 

 

 

 

O

 

T

 

 

 

 

 

P

 

 

 

Q

S

 

 

 

Q. BASE

R

R.FEET (4)

S.POWER CORD

T.REMOTE CONTROL

U. SECURITY SCREW

FIGURE 1

 

Image 2
Contents Touch Stand Fan HASF1796RCFan Head Assembly Assembly InstructionsBase / Pole Assembly Operating Instructions Adjustment InstructionsCLEANING/MAINTENANCE Instructions FAN StorageService Instructions Three 3 Year Limited Warranty

HASF1796RC specifications

The Holmes HASF1796RC is a prominent choice for those seeking effective air purification solutions in their homes or offices. This air purifier combines advanced technology with user-friendly features to improve indoor air quality, ensuring that you and your family breathe cleaner air.

One of the key characteristics of the Holmes HASF1796RC is its efficient HEPA filtration system. This feature captures up to 99.97% of airborne particles as small as 0.3 microns, including dust, pollen, pet dander, and smoke. This level of filtration is essential for individuals with allergies or respiratory issues, as it significantly reduces the presence of allergens in the air.

In addition to its HEPA filter, the HASF1796RC is equipped with a built-in activated carbon filter. This component is specifically designed to eliminate odors caused by cooking, pets, smoke, and other household activities. The combination of HEPA and activated carbon filtration makes this model exceptionally comprehensive in addressing a variety of air quality concerns.

The design of the Holmes HASF1796RC is another standout feature. It boasts a sleek and modern aesthetic that can easily blend into any home or office decor. The compact size makes it suitable for various rooms, including bedrooms, living rooms, and workspaces. Its portability allows users to move it from room to room as needed.

Another significant technological innovation in the HASF1796RC is its three-speed fan control. Users can easily adjust the fan speed depending on their air purification needs and preferences. When maximum purification is required, the high-speed setting can quickly circulate and clean the air, while the low-speed setting operates quietly, making it ideal for nighttime use.

For added convenience, the Holmes HASF1796RC comes with an easy-to-use filter replacement indicator. This feature alerts users when it is time to replace the filters, ensuring the air purifier operates at optimal efficiency. The overall maintenance is straightforward, making it a user-friendly option for anyone new to air purifiers.

In summary, the Holmes HASF1796RC air purifier is an excellent investment for anyone looking to improve their indoor air quality. With its powerful HEPA and activated carbon filtration, stylish design, adjustable fan speeds, and user-friendly features, it offers a comprehensive solution for cleaner air at home or in the office.