Empire Comfort Systems VFCT25-3 Clearances, Assembly of Cast Iron Outer Casing Stove Casting

Page 8

CLEARANCES

When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.

Top of appliance (ceiling)

36

inches

Rear Wall

3

inches

Side Wall

6

inches

Heater Corners (45° angle) to Wall

4

inches

Floor

0

inches

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Provide adequate clearances around air openings.

Adequate accessibility clearances for purposes of servicing and proper operation must be provided.

Installation on Rugs and Vinyl

If this appliance is installed directly on carpeting, vinyl or other combustible material, other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance.

Figure 2

Figure 3

Figure 4

Assembly of Cast Iron (Outer Casing) Stove Casting

Appliance Hardware Package Parts List

Part

Part

Quantity

Description

Number

Supplied

1/4-20 x 3/8" Phillips Head Bolt

R-3646

8

1/4" 9/32 Washer

R-1150

8

10 - 24 Nut

R-1118

2

 

 

 

Attention: Included in the hardware package are (8) 1/4" inside diameter washers. A 1/4" washer may be used with a 1/4-20 x 3/8" bolt when assembling the stove casting parts. If a bolt hole is not tapped deep enough for a tight fit between stove casting parts, the 1/4" washer can be used as a shim to provide a tight fit.

The 1/4" washers are not required for assembly of the stove casting if all the bolt holes are tapped to a proper depth.

1.Remove casting from shipping carton. Place casting on non- abrasive surface.

2.Remove burner assembly, logs, hardware and sheet metal parts from shipping carton.

3.Attach rear cover to casting sides with 1/4 - 20 x 3/8" bolts (2 per side) as shown in Figure 5.

4.Attach casing bottom to casting sides with 1/4 - 20 x 3/8" bolts (2 per side).

5.Align and place (2) clearance holes on front legs of burner assembly over (2) rear weld studs in casing bottom.

6.For VFCR-25 only, attach green wire to the TH terminal on gas valve. Attach black wire to the TH/TP terminal on gas valve from wiring harness on valve cover plate.

7.Attach three (3) knob extensions onto gas valve as shown in Figure 6.

8.Align and attach (2) clearance holes on MV switch bracket as shown in Figure 6 onto (2) front weld studs in casing bottom with (2) 10-24 nuts.

9.Attach casting front onto casting sides as shown in Figure 7.

Page 8

16937-4-0806

Image 8
Contents Installation Instructions Table of Contents Important Safety Information Safety Information for Users of LP-GAS LP-GAS Warning OdorSpecifications IntroductionWater Vapor a BY-PRODUCT of Unvented Room Heaters GAS Supply Bruce Special CopyAssembly of Cast Iron Outer Casing Stove Casting ClearancesLeveling Bolts LOG Placement Proper Installation SequenceImportant Installation Guidelines Vfcr -25, VFCT-25 Photos Operation INSTRUCTIONS/FLAME Appearance VFCM-25 Lighting Instructions What to do if YOU Smell GASVFCR-25 Lighting Instructions Piezo Ignitor HI/LO Regulator Control KnobVFCT-25 Lighting Instructions Pilot Flame Characteristics VFCR-25 PilotPilot Flame Characteristics WiringRecommended Wire Gauges Millivolt Operating InstructionsMaintenance Operating GuidelinesTroubleshooting Parts List Index Part Number DescriptionParts View HOW to Order Repair Parts Service Notes

VFCT25-3, VFCM-25-3. VFCR-25-3 specifications

Empire Comfort Systems has long been recognized for its commitment to delivering high-quality heating products that cater to a variety of residential and commercial needs. Among their offerings, the VFCM-25-3, VFCR-25-3, and VFCT-25-3 stand out as exceptional models in the realm of vent-free gas fireplaces. These units are designed to provide warmth and comfort while boasting innovative technologies, efficiency, and user-friendly features.

The VFCM-25-3 model is particularly notable for its contemporary design, offering a sleek appearance that can complement various home decors. It utilizes a dual fuel system, allowing it to run on both natural gas and propane. This flexibility ensures that users have options based on their heating preferences and availability of fuel sources. The in-built thermostat control enables automatic adjustments to maintain a consistent temperature, providing comfort without the need for constant monitoring.

Meanwhile, the VFCR-25-3 model focuses on efficiency and an elegant, traditional style. It incorporates Empire's cutting-edge technology that allows for a quick and efficient heat production. Featuring a unique safety pilot system, the VFCR-25-3 automatically shuts off the gas supply in case of a malfunction, ensuring peace of mind for homeowners. Additionally, this model is equipped with a ceramic burner that produces realistic flame patterns, creating a warm ambiance in spaces of various sizes.

The VFCT-25-3 variant is designed with versatility and user convenience in mind. This model comes with vent-free technology that allows for installation in locations where venting would be challenging or impossible. Its adjustable flame height allows users to customize the experience, creating a customizable ambiance that caters to personal preferences. Moreover, the unit is equipped with a built-in oxygen depletion sensor (ODS) that ensures safe operation by shutting off the unit if oxygen levels drop to unsafe levels.

All three models share common features like easy installation, thermal efficiency, and low emissions, making them environmentally friendly options. They are perfect for both supplemental and primary heating, providing comfort during the cold winter months without the need for extensive alterations to existing structures. Empire Comfort Systems continues to lead the market with innovative solutions that prioritize warmth, safety, and aesthetic appeal. Whether you choose the VFCM-25-3, VFCR-25-3, or VFCT-25-3, you can be assured of quality comfort and reliability for years to come.