Empire Comfort Systems LS-24H-1, LS-30H-1 Important Installation Guidelines, General Information

Page 3

IMPORTANT INSTALLATION GUIDELINES

Proper Log Placement

Log placement is critical to proper burner performance. Logs must be correctly positioned onto the burner. The photos in this manual show the proper pinned position for logs on this set. Owners need to be shown proper log placement and instructed not to move the logs.

Logs must fit firmly onto the burner when positioned as shown in the photos. Malformed logs or logs with sloppy pin holes must be replaced.

Proper Placement of Rock Wool and Decorative Lava Rock Rock wool can be added to burners for a glowing ember effect. It must be positioned only on the front portion of the burner. The photos in this manual show the proper placement of rock wool.

Decorative lava rock or small wood pieces should never be placed on the burner. These items are only for placement on the floor of the fireplace or firebox.

Proper Primary Airflow into Burner

For proper burner operation and flame appearance, the flow of primary air into the venturi tube, located on the rear of the burner, must not be reduced. This flow of air is reduced if dirt, lint or other obstructions build-up around or inside the venturi.Any obstruction in the venturi tube area must be removed. The flow of air into the venturi is also reduced if the gas orifice isn’t centered in the venturi inlet and/or is not aligned with the venturi. Any misalignment of the burner orifice may be corrected by bending the shutter cap holding the orifice to the inlet of the venturi tube.

Ceiling Fans, Portable Fans or Logs Installed Near Cold Air Returns

Ceiling fans or oscillating floor type fans need to be monitored during the operation of vent-free logs. If the air blows directly into the flame causing it to impinge on the log set, or firebox, it should be turned off or redirected. Ceiling fans could be reversed to possibly eliminate flame impingement, and the floor fan could be redirected. Upon installation, be aware of any cold air returns or vents in the proximity of the log set. Any draft created around a vent-free log set can cause the flame to impinge on the log and create a sooting situation.

WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns.

WARNING: Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this heater.

Candles

Avoid the use of scented or decorative candles while the log set is in operation. Candles produce a residue in the air that creates a soot like substance. Burning candles while the log set is operating magnifies the problem. It should be noted that candles, in general, produce soot. The amount of time burned and the quantity of candles burned will determine the amount of soot produced and deposited.

Make Owners Aware of Proper Log Set Operation

Properly installed and properly maintained log sets do not deposit soot on the logs. If users see soot appear on a log, call for service. Do not continue to operate the log set.

Sunken Fireplace

If installing this unit into a sunken fireplace, you must raise the floor to insure adequate airflow and guard against sooting. Raise fireplace floor using a non-combustible material, which is secure.

Glass Doors

Make sure that glass doors are open during all operations of the logset.The opening of the glass door frame should be the dimension used for the minimum front opening of the firebox.

Woodburning Fireplaces

The interior of the firebox and the chimney should be cleaned and free of all creosote before installing a gas burning log set. Creosote will soften when heated and can drop on the logset causing odors and possibly sooting.

WARNING: Before installing in a solid-fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner.

GENERAL INFORMATION

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equip- ment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term "qualified agency" means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for (a) the installation, testing, or replacement of gas piping or (b) the connection, installation, testing, repair, or servicing of equipment; that is experienced in such work; that is familiar with all precautions required, and that has complied with all the requirements of the authority having jurisdiction.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/ NFPA54.*

*Available from the American National Standards Institute, Inc. 11 West 42nd St., New York, N.Y. 10018.

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Mas- sachusetts.

Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.

In the State of Massachusetts, unvented propane and natural gas-fired space heaters shall be prohibited in bedrooms and bathrooms.

20173-1-0506

Page 3

Image 3
Contents Installation Instructions Table of Contents General Information Important Installation GuidelinesLOG Placement Ember Placement LS-18H-1 Photos Ember Placement LS-24H-1 Photos Ember Placement LS-30H-1 Photos HOW to Order Repair Parts Parts List and Parts View

LS-30H-1, LS-24H-1, LS-18H-1 specifications

Empire Comfort Systems has established itself as a prominent name in the heating industry, with products that blend efficiency, durability, and contemporary design. Among its impressive lineup are the LS-18H-1, LS-24H-1, and LS-30H-1 models, which stand out for their innovative features and exceptional performance.

The LS-18H-1, LS-24H-1, and LS-30H-1 heaters are crafted for versatility, with a sophisticated design that complements various home decors. These models are available in multiple finishes, allowing homeowners to choose the perfect fit for their interiors. The compact design of these units ensures they can be installed in diverse spaces, maximizing both aesthetics and functionality.

One of the key features of these heaters is their advanced vent-free technology, which allows them to operate without the need for a traditional chimney or flue. This not only simplifies installation but also enhances energy efficiency. By utilizing the room's air for combustion, these units provide a more efficient heating solution while minimizing heat loss.

Each model is equipped with an Automatic Safety Shut-Off System, ensuring peace of mind by providing an additional layer of safety. This technology automatically turns off the heater if it detects low oxygen levels in the room. Additionally, the models feature variable heat settings, enabling users to easily adjust the warmth according to their comfort preferences.

The LS-18H-1, LS-24H-1, and LS-30H-1 are designed to deliver powerful heating capabilities without compromising on aesthetics. They are equipped with modern controls that allow for easy operation, including adjustable flame settings and a user-friendly interface.

Furthermore, these Empire Comfort Systems models are recognized for their low emissions, making them an eco-friendly heating option. They contribute to a healthier home environment while reducing the impact on the atmosphere.

In summary, Empire Comfort Systems' LS-18H-1, LS-24H-1, and LS-30H-1 heaters are not just efficient and reliable; they also incorporate cutting-edge technology and safety features that make them an excellent choice for any home. With their sleek designs, exceptional performance, and commitment to safety and efficiency, these models represent the best of modern heating solutions. Embracing these heaters will not only enhance your home’s heating capabilities but also contribute to a more sustainable environment.