Karcher NT 65/2 ECO manual Care and maintenance, Clean electrodes, Fault instructions

Page 7

Operating instructions

NT 65/2 Eco *VEX

English

Care and maintenance

Danger!

Always pull out the mains plug when working on the suction machine.

Replacing the flat pleated filter or the exhaust air filter

!Open the filter cover (1)

!Replace the flat pleated filter (2) or the exhaust air filter (3)

!Close the filter cover, it must engage audibly

Clean electrodes

!Unlock and remove the suction head

!Clean electrodes

!Replace the suction head and lock it in place

Fault instructions

 

! Replace the flat pleat filter.

 

! Check drain hose for leaks

 

 

The suction turbine does not

 

(if provided).

 

Dust ejects when sucking

run

 

! Check the cable, plug, fuse and

 

! Check the proper mounting

socket.

 

position of the flat pleat filter.

! Switch on the machine.

 

! Replace the flat pleat filter.

The suction turbine switches off

 

The (wet-vacuuming) automatic

! Empty the container.

 

switch-off does not respond

 

 

! Clean the electrodes as well as

The suction turbine does not

 

the space between them.

restart following emptying of

 

! Constantly check fill level when

the container

 

vacuuming electrically non-

! Switch the appliance off and

 

conductive liquids.

wait for 5 s, switch it on again

 

Power Filter Clean switches

after 5 s.

 

! Clean the electrodes as well as

 

regularly

the space between them.

 

! Detach blocked suction nozzle

 

 

or end of hose.

The suction power decreases

 

! Stop continuous vacuuming

! Remove the parts clogging up

 

from liquid tank or deactivate

the suction nozzle, the suction

 

the Power Filter Clean function

tube, the Power Filter Clean

 

(see chapter on wet-

handle, the suction hose or the

 

vacuuming).

flat pleat filter.

 

! Remove the parts clogging up

! Change the paper filter bag.

 

the suction nozzle, the suction

! Actuate the filter

 

tube, the Power Filter Clean

cleaner: Power Filter Clean

 

handle, the suction hose or the

several times at the handle.

 

flat pleat filter.

! Engage the filter cover

 

! Replace the flat pleat filter.

properly.

 

 

7

Image 7
Contents NT 65/2 Eco *VEX NT 65/2 Eco *VEX NT 65/2 Eco *VEX Dry suction Environmental protectionDisposal of used units Intended useTo deactivate Power Filter Clean Slider 1 position up Filter de-duster Power Filter CleanWet-vacuuming To deactivate Power Filter CleanClean electrodes Care and maintenanceFault instructions Applied national standards EC conformity declarationRelevant EC directives Applied harmonised standards DIN ENUSA Mm x 480 mm x 920 mm Ohne Zubehör AC 60 Hz 18 a 10,0 m 65 l648-919 50 l DB a Max x 54 l/s Max mbar Umgebungs TemperaturTransformateur NT 65/2 Eco *VEX Zubehör /Accessories/Accessoires NT 65/2 Eco *VEX