MGD Series Gas Furnace

 

 

 

 

 

 

Installation Instructions

SPECIFICATIONS

 

 

 

 

 

 

 

 

 

80 AFUE- AUTOMATIC HOT SURFACE

 

 

 

 

 

 

 

 

IGNITION

 

 

 

 

 

 

 

 

 

Model No.

MGD60-E3A

MGD75-E3A

MGD90-E3A

 

 

MGD60-E5A

MGD75-E5A

MGD90-E5A

Input, BTUH

60,000

75,000

90,000

 

 

60,000

 

75,000

90,000

Output, BTUH

48,000

60,000

72,000

 

 

48,000

 

60,000

72,000

AFUE, %

80.0

81.0

80.0

 

 

80.0

 

81.0

80.0

With A-Coil Cabinet

YES

YES

YES

 

 

YES

 

YES

YES

Ignition Type

Auto-Elect

Auto-Elect

Auto-Elect

 

 

Auto-Elect

 

Auto-Elect

Auto-Elect

Air Temperature Rise, Range-F

40-70

45-75

50-80

 

 

40-70

 

45-75

50-80

Blower

10 X 8, 1/3 HP, 3 SPD

 

 

10 X 8, 3/4 HP, 4 SPD

Designed Max Outlet Air Temp-F

 

 

 

165 °

 

 

 

Max. External SP (Duct),In. W.C.

 

 

.30 Heating

 

 

 

Factory Equipped Fuel

 

Natural Gas (Factory Equipped) - LP Orfice Furnished

 

High Altitude

For elevations above 2,000 feet, reduce input 4% for each 1,000 ft. elevation above sea level

Furnace Flue Pipe

Must Use RJS Roof Jack for Sloped Roof or RJF Roof Jack for Flat Roof

Gas Connection

 

 

1/2" FPT

 

 

 

Electric Service

 

 

115 VAC, 60 HZ, 1 PH

 

 

 

Fuse or Circuit Breaker

 

 

15 Amp

 

 

 

Thermostat Circuit

 

 

24VAC, 60Hz, 40VA

 

 

 

Filters

 

 

1-16"x40"x1" Washable

 

 

 

PRODUCT CODE

 

 

 

 

 

 

PART NO.

DESCRIPTION

NOTES

 

 

 

90-RJF1729-AL

Body, Roof Jack, Gas-FLAT

Height 94 1/2 X 106 1/2

 

 

 

90-RJF2551-AL

Body, Roof Jack, Gas-FLAT

Height 102 1/2 X 128 1/2

 

 

 

90-RJS1729-AL

Body, Roof Jack, Gas-SLOPE 3/12

Height 94 1/2 X 106 1/2

 

 

 

90-RJS2551-AL

Body, Roof Jack, Gas-SLOPE 3/12

Height 102 1/2 X 128 1/2

 

 

 

90-RJS3868-AL

Body, Roof Jack, Gas-SLOPE 3/12

Height 115 1/2 X 145 1/2

 

 

 

90-RJS6399-AL

Body, Roof Jack, Gas-SLOPE 3/12

Height 140 1/2 X 176 1/2

 

 

 

90-RJCRWN-AL

Crown, Roof Jack, Gas

Use w/ Gas Roof Jack Body

 

 

 

90-TRN-RNG

Ceiling Trim Ring, Roof Jack

Trim out to inside RJ - Pipe

 

 

 

90-OUTXT16-AL

Roof Jack Outdoor Extension - Gas 16"

Extend pipes / crown - 16 in.

 

 

 

90-INXST10-AL

Roof Jack Indoor Extension - Gas 10"

Extend pipes / crown - 10 in.

 

 

 

90-RJS56

5-6/ 12 Slope, Roof Saddle Adapter

Add to RJS 3/12 Roof Jack

 

 

 

90-DCU0-01

86AA0013 Duct Conn + 87FB0005 Flr Base

Floor to Duck 1 in. - 4 in.

 

 

 

90-DCU0-02

86AA0014 Duct Conn + 87FB0005 Flr Base

Floor to Duck 6 in. - 8 in. STD

 

 

 

90-DCU0-03

86AA0015 Duct Conn + 87FB0005 Flr Base

Floor to Duck 8 in. - 12 in.

 

 

 

90-CABEXT4

White, Top, Cabinet Extender Plate

Fill alcove 76" top opening

 

 

 

87-1008-3/12A1

A/C Blower, 3 Speed - 1/3 HP

2 - 4 Ton A/C

 

 

 

87-1008-4/16A1

A/C Blower, 3 Speed - 3/4 HP

2 - 5 Ton A/C

 

 

 

 

 

 

Heat Controller, Inc. Jackson, MI 49203

MGD Installation Instructions 2

Image 2
Contents Save this Manual Sealed Combustion Downflow MGD Series GAS FurnaceGeneral Information Specifications Product CodeSafety Considerations Closet Installations Return AIR Alcove InstructionPage Page Sealed Combustion Roof Jack Required Cutting Roof Jack Opening Installing Roof JackInstallation in Snow Regions Roof Jack on HI-PITCH RoofConnect Power Supply GAS Pipe and TUBING-MIN Sizes Model Type Length Tubing MGD Wiring DIAGRAM, MGD Replacement Parts MGD Gas Furnace Parts List MGD Series Gas Furnace Installation Instructions