Harman Stove Company SF1500A manual Coil Installation, Special Instructions

Page 16

Special Instructions

Coil Installation:

Hot Water Out

Pressure

 

Cold Water In

 

 

 

 

Relief Valve

 

Automatic

 

1

 

Air Valve

 

 

2

 

 

 

 

 

 

5

 

 

 

Pressure

 

 

 

Relief Valve

 

 

 

(Must be within

 

 

 

2 feet of coil)

 

Existing Water

3

3

 

 

 

 

 

 

Heater

 

 

 

 

 

10 Feet Maximum

Drain

Valve 4

Rear Of Furnace

Plumbing Diagram For Thermo-Siphon Method - Maximum Distance = 10 Feet

Place one of the supplied nuts on each leg of the coil. Place the coil through the holes on the back of the furnace, and adjust the nuts so that the pipes stick out about 1¼ to 1½ inches from the rear of the furnace. Place the flat washers and gaskets over each pipe and tighten the nuts. You are now ready to run the piping.

This simple method is the most economical. However, the existing water heater must be less than 10 feet from the furnace. The water inlet, where the Temperature / Pressure Relief valve is located, must be higher than the top leg of the water coil. The water heater should be elevated, if necessary, to allow for proper thermo-siphon action.(The method by which hot water will circulate automatically through the system.)

A. Shut off the water heater and the water supply to it. Drain the tank completely.

B. Remove the Temp. / Presure relief valve and discard. Install a short 3/4 in. nipple and tee (1) along with a new relief valve.

C. run 3/4 in. copper tubing between the water tank and the top leg of the coil. Install a 3/4 in vent elbow and automatic “float type” air vent (2) in the high point of the line. Within 2 feet of the top leg of the coil, install a 150 lb. pressure relief valve (5). Run 3/4 in. tubing from the release exit of both relief valves downward (3) so the hot water can escape in the event of an overheat situation.

D. Remove the drain valve, at the bottom of the tank. Install a short 3/4 in. nipple and tee and re-install the drain valve to the tee (4). Run 3/4 in. tubing between the drain / tee combination and the lower leg of the water coil. After all of the connections are secured, refill the water tank. Turn on the water heater only after the tank has been completely refilled.

16

Image 16
Contents Installation & Operating Manual SF1500A, SF2500A, SF2600A, SF3500A Hot Air FurnacesTable of Contents Packing List SF2600 Packing List for SF1500, SF2500 & SF3500 Furnace Installation Figure aInstalling Wood/Coal High Limit Switch AssemblyMounting The Oil Burner- SF2600 only Venting GuidelinesSF2600 Mounting The Blower And Filter BoxFurnace Installation Wiring WiringSF3500 Wiring Diagram SF2600 Wiring Diagram Duct Work Duct Work and Operating InstructionsOperating Instructions SF 2600 Oil Operation as Backup Operating InstructionsOperating Instructions/Safety Tips Safety TipsMaintenance Cleaning Heat-Exchanger SF2600 OnlySpecifications Coil Installation Special InstructionsCirculating Pump Method Distance = 10 Feet or More SF2600 Burner Set Up SF2600 Oil Burner SetupService Parts Part number list on followingStocked at depot SF2500A Stocked At depotSF3500A SF3500A SF2600SS 20 Ft 00-53500 Grate Holder 2 Cast Harman Central Heating Products Limited Warranty Signature of Boxer
Related manuals
Manual 20 pages 26.37 Kb

SF1500A specifications

The Harman Stove Company has established itself as a leader in the heating industry, known for its innovative and efficient wood and pellet stoves. The SF series, including models SF2600A, SF1500A, SF3500A, and SF2500A, showcases the company's commitment to high-quality craftsmanship and cutting-edge technology.

The SF2600A stands out with its robust heat output, designed for larger spaces. With a capacity to heat up to 3,000 square feet, it features a large firebox capable of accommodating extended burns, which means less frequent refueling. The CleanStart technology ensures that the stove ignites quickly and efficiently, minimizing smoke emissions and energy waste. Users will appreciate the integrated air wash system, which keeps the glass clean, providing an unobstructed view of the flames.

Meanwhile, the SF1500A serves as an excellent choice for smaller homes or cozy spaces, heating areas up to 1,800 square feet. Its compact design does not compromise on performance. The model also incorporates Harman's advanced combustion technology, which optimizes airflow for a cleaner burn. This efficiency not only helps in reducing heating costs but also contributes to a more environmentally-friendly operation.

The SF3500A is engineered for those who demand maximum warmth and efficiency. With a substantial heat output, it can easily heat areas exceeding 3,500 square feet. This model integrates a state-of-the-art digital control board that allows users to manage their heating needs effortlessly, providing options for programmable settings and real-time monitoring. It also boasts a high-efficiency rating, ensuring users get the most from their fuel, with longer burn times and minimal ash production.

Lastly, the SF2500A offers a balanced approach, capable of heating spaces up to 2,500 square feet. It features adjustable air controls, enabling users to customize their heating experience based on personal preference. The built-in diagnostics system helps troubleshoot potential issues, providing peace of mind for homeowners. With elegant styling and various finishing options, the SF2500A can seamlessly integrate into any home décor while delivering dependable warmth.

Each model in the Harman SF series exemplifies durability, performance, and user-friendly operation, making them ideal for anyone seeking a reliable heating solution in today's energy-conscious landscape.