Goodman Mfg Multi-Position, Two-Stage/Variable-Speed Gas Furnace Specifications, GMV95, GCV9

Page 3

PRODUCT SPECIFICATIONS

SPECIFICATIONS

 

GMV95

GMV95

GMV95

GMV95-

GCV9

GCV9

GCV9

 

0453BXB

0704CXB

0905DXB

1155DXB

0704CXB

0905DXB

1155DXA

Heating Capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High Fire Input¹

46,000

69,000

92,000

115,000

69,000

92,000

115,000

 

 

 

 

 

 

 

 

High Fire Output¹

45,000

67,000

90,000

109,000

65,000

87,000

109,000

 

 

 

 

 

 

 

 

Low Fire Input¹

32,000

48,000

64,000

80,000

48,000

64,000

80,000

 

 

 

 

 

 

 

 

Low Fire Output¹

30,800

46,400

61,700

77,400

45,000

60,100

77,400

 

 

 

 

 

 

 

 

AFUE²

95

95

95

95

93

93

93

 

 

 

 

 

 

 

 

Tons AC @ 0.5” ESP

1.5 - 3.0

1.5 - 4.0

2.0 - 5.0

2.0 - 5.0

1.5 - 4.0

2.0 - 5.0

2.0 - 5.0

 

 

 

 

 

 

 

 

Temperature Rise Range (°F)

30 - 60

30 - 60

30 - 60

30 - 60

30 - 60

30 - 60

40-70

 

 

 

 

 

 

 

 

Circulator Blower

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Size (D x W)

10” X 7”

10” X 10”

11” X 10”

11” X 10”

10” x 10”

11” X 10”

11” X 10”

 

 

 

 

 

 

 

 

Horespower @ 1750 RPM

½

¾

1

1

¾

1

1

 

 

 

 

 

 

 

 

Speed

 

Variable

 

 

Variable

 

 

 

 

 

 

 

 

 

Vent Diameter³

2”

2”

3”

3”

2”

3”

3”

 

 

 

 

 

 

 

 

No. of Burners

2

3

4

5

3

4

5

 

 

 

 

 

 

 

 

Filter Size (in²)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disposable

288

384

480

486

384

480

486

 

 

 

 

 

 

 

 

Permanent

576

768

960

972

768

960

972

 

 

 

 

 

 

 

 

Electrical Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min. Circuit Ampacity (amps)4

10.4

12.8

14.6

14.6

12.8

14.6

14.6

 

 

 

 

 

 

 

 

Max. Overcurrent Protection5

15 amps

15 amps

15 amps

15 amps

15 amps

15 amps

15 amps

 

 

 

 

 

 

 

 

Ship Weight (lbs)

133

135

172

175

135

172

175

 

 

 

 

 

 

 

 

1– Natural Gas BTU/h

2– DOE AFUE based upon Isolated Combustion System (ICS)

3– Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2” or 3” in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2” or 3” diameter PVC.

4– Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.

5– Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.

Notes:

All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.

Gas Service Connection ½” FPT

Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.

SS-GMV95

www.goodmanmfg.com

3

 

 

 

Image 3
Contents TWO-STAGE/VARIABLE-SPEED GMV95/GCV9Afue NomenclatureSpecifications GMV95GCV9 GMV95 Dimensions ModelPosition Sides Rear Front Bottom Flue Top GCV91155DXB GCV9 DimensionsGMV95 LOW-STAGE Cooling Speeds GMV95 HIGH- or SINGLE-STAGE Cooling SpeedsC. ESP GMV95 Heating SpeedsGMV95 Blower Performance GCV90905DXA GCV9 Cooling SpeedsGCV90704CXA GCV91155DXACFM AUTO-COMFORT ModeStandard Altitude Installations GCV9 Cooling Speeds747 GCV9 Heating SpeedsGCV9 Blower Performance GMV95/ GCV9 Wiring Diagram GMV95/ GCV9 Blower Assembly Schematic GMV95/ GCV9 S Chematics Using SocketsAccessories ThermostatsModel Description

GMV95/GCV9, Multi-Position, Two-Stage/Variable-Speed Gas Furnace specifications

The Goodman Manufacturing Multi-Position, Two-Stage/Variable-Speed Gas Furnace (GMV95/GCV9) stands out as an advanced heating solution designed to deliver comfort and energy efficiency for residential spaces. Recognized for its reliability and impressive performance, this furnace is a popular choice among homeowners looking to enhance their indoor climate.

One of the key features of the GMV95/GCV9 is its two-stage heating capability. This dual-stage operation allows the furnace to run at a lower capacity for extended periods during mild weather, ensuring a more consistent temperature while minimizing energy consumption. When colder conditions are present, the furnace can efficiently ramp up to full capacity to provide the necessary warmth quickly. This adaptability results in lower utility bills while maintaining optimal comfort levels throughout the home.

Another critical characteristic of the GMV95/GCV9 is its variable-speed blower motor. The variable-speed technology allows for increased airflow control and quieter operation. This feature means that the furnace can adjust its fan speed based on the heating requirements, providing a consistent and comfortable temperature without the disruptive noise associated with traditional systems. The reduced sound levels make it particularly suitable for homes where quiet operation is a priority.

Safety features are paramount in the design of the GMV95/GCV9. The furnace is equipped with safety devices such as an integrated control board and a self-diagnostic system, allowing for real-time monitoring and quicker problem detection. Additionally, the furnace includes a durable heat exchanger built of stainless steel, ensuring longevity and efficiency while minimizing the risk of failure.

The GMV95/GCV9 is designed with flexibility in mind, allowing for multiple installation configurations, including upflow, downflow, and horizontal applications. This adaptability makes it an excellent option for various home layouts and renovation projects.

Finally, the Goodman's GMV95/GCV9 is incredibly energy-efficient, boasting an AFUE rating of up to 95%. This efficiency not only translates into savings on heating bills but also makes it an environmentally friendly choice, reducing greenhouse gas emissions compared to less efficient models.

In summary, the Goodman Manufacturing Multi-Position, Two-Stage/Variable-Speed Gas Furnace (GMV95/GCV9) combines advanced features, robust safety elements, and energy efficiency to meet the needs of modern homeowners. Its innovative technology and reliability make it a valuable investment in home heating comfort.