Field Controls UV-1500C IV. for Area or Room Operation, VI. Suspension or Drop Ceiling Option

Page 3
Page 3

IV. FOR AREA OR ROOM OPERATION

1.Place the UV-1500C in the desired area; plug the power cord into a standard 120-volt wall receptacle.

2.Turn the speed control knob clockwise to turn on the unit and to adjust the motor/fan speed to the desired airflow. (See Figure 1)

3.After the fan has started, the LED light will show a continuous “GREEN” color indicating proper unit operation.

V. WALL MOUNTING OPTION (The UV-1500C is supplied with four mounting brackets to allow

Figure 1

 

the unit to be mounted onto a wall)

 

1.To install the mounting brackets, remove the eight mounting screws from the back of the UV-1500C shown in Figure 2.

2.Install the four mounting brackets onto the back of the housing securing them with the mounting screws you just removed. (See Figure 3)

3.Determine the desired location on the wall (a 120-volt wall receptacle should be within 5 feet of the unit) and mark the mounting screw locations based on the dimensions given in figure 4A.

4.Install four drywall anchors or other appropriate fasteners rated for at least a 15 lbs load capacity. (See Figure 4B)

5.Mount the unit to the wall. (See Figure 5)

6.Plug the power cord into a standard 120-volt wall receptacle. Turn the speed control knob clockwise to turn on the unit and adjust the motor/fan speed control to the desired airflow.

7.After the fan has started the LED light will show a continuous “GREEN” color indicating proper unit operation.

Mounting

 

Screws

Figure 3

 

Figure 2

VI. SUSPENSION OR DROP CEILING OPTION

Figure 4A

Figure 4B

 

 

 

 

Figure 5

Figure 6

The UV-1500C must be wired in accordance with the National Electrical Code and any applicable local codes. The UV-1500C must be hard-wired using metal-shielded cable, BX cable or other similar wiring methods.

1.Install the four mounting brackets onto the back of the housing securing them with the eight mounting screws (See Figure 2 & 3).

2.Mount the supplied drop ceiling body extension covers onto the sides of the UV-1500C. These covers allow the UV-1500C to fit into a standard 2 foot by 2 foot ceiling tile space (23-3/4”). Align the edges of the extension cover to the front of the UV-1500C body and use the holes in the cover as a template to mark the mounting hole locations on the UV- 1500C body. (See Figure 7)

Figure 7

WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire™ Air Purifying System with the UV chamber door open. Avoid touching the glass portion of the lamp with your hands.

Image 3
Contents Items Included in KIT Safety ConsiderationsIII. UV-1500C Check OUT Procedure Indication for USEII. General Information VI. Suspension or Drop Ceiling Option IV. for Area or Room OperationPage Diagram a VII. MaintenanceVI. Replacement Procedures VIII. Replacement Parts List VII. Troubleshooting GuideProvisions Limited Warranty46448400 Rev D 09/05

UV-1500C specifications

The Field Controls UV-1500C is an advanced ultraviolet (UV) air purification system designed to enhance indoor air quality in residential and commercial environments. This cutting-edge technology harnesses the power of UV-C light to eliminate airborne pathogens, allergens, and other harmful particles, promoting a healthier living and working space.

One of the main features of the UV-1500C is its powerful UV-C light source. Operating at a wavelength of 254 nanometers, the system effectively disrupts the DNA of microorganisms, including bacteria, viruses, mold, and mildew, rendering them inactive and unable to reproduce. This not only reduces the risk of airborne illnesses but also combats musty odors and improves overall air freshness.

Another notable characteristic of the UV-1500C is its compact and efficient design. The unit can be easily mounted within existing HVAC systems, making installation straightforward and hassle-free. By working in conjunction with the HVAC system, the UV-1500C continuously treats the air as it circulates, ensuring that all areas of the space benefit from UV purification.

The UV-1500C also incorporates a smart control system that allows for customizable settings based on specific air quality needs. Users can adjust the intensity and operating times of the UV light, providing versatility in managing indoor air quality. This feature not only enhances user convenience but also maximizes energy efficiency, making the device cost-effective to operate.

Field Controls emphasizes safety and reliability, and the UV-1500C is no exception. The unit is equipped with safety features to prevent UV exposure to occupants, ensuring that the purification process does not pose any health risks. Additionally, the LED indicators provide real-time monitoring of system performance, alerting users to any maintenance needs.

In conclusion, the Field Controls UV-1500C is an innovative UV air purification solution that stands out for its effectiveness, user-friendly features, and safety measures. By utilizing advanced UV-C technology, this system significantly improves indoor air quality, making spaces cleaner and healthier for occupants. Whether for residential or commercial applications, the UV-1500C is a reliable choice for those looking to invest in superior air purification systems.