Field Controls UV-16/24 installation instructions Maintenance

Page 5

MAINTENANCE

WARNING: Disconnect power to the transformer before commencing inspection and cleaning.

NOTE: Wear disposable, non-absorbent protective gloves prior to inspection procedure in case of accidental breakage of glass.

1.We recommend inspecting and cleaning the lamp at least every 6 months. Frequency depends upon the environment. Such as: the type of air filter, duration of use and replacement cycle.

2.To maintain maximum output intensity, replace the UV-Aire lamp annually. The lamp should operate continuously for maximum lamp life and light effectiveness.

Diagram A

Diagram B

WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-AireAir Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands.

page 5

Image 5
Contents Items Included in KIT UV-AIRE AIR Purifying SystemGeneral Information Safety ConsiderationsSizing and Selecting Units InstallationPage Maintenance Replacement Procedure Replacement Parts List Troubleshooting GuideLimited Warranty

UV-16/24 specifications

The Field Controls UV-16/24 is an advanced ultraviolet (UV) air purification system designed to improve indoor air quality in residential and commercial settings. The unit is particularly effective in combatting airborne pathogens, mold spores, and volatile organic compounds (VOCs), making it an essential addition to HVAC systems.

One of the standout features of the UV-16/24 is its dual UV-C lamp configuration. This design maximizes germicidal efficacy by offering thorough exposure to UV light, effectively neutralizing microorganisms present in the air as it circulates through the HVAC system. The 16- or 24-inch length of the lamps also optimizes coverage for various system sizes.

The technology behind the UV-16/24 ensures that the units operate efficiently while minimizing energy consumption. The implementation of high-output UV lamps allows for maximum disinfection within a compact form factor. The system boasts easy installation within existing HVAC frameworks, which makes it suitable for both new builds and retrofitting older systems.

Another notable characteristic of the UV-16/24 is its durable construction, designed to withstand the rigors of continuous operation. The unit features corrosion-resistant components and housing, ensuring longevity and reliability even in varying environmental conditions.

Safety is prioritized in the UV-16/24, featuring automatic shutoff capabilities when the housing is opened for maintenance. This ensures that users and technicians are not exposed to harmful UV rays during lamp replacement or service.

The Field Controls UV-16/24 operates quietly, making it a desirable option for residential settings where noise can be a concern. By utilizing UV-C technology, it does not rely on chemicals, thus contributing to a healthier indoor environment without introducing harmful substances.

Additionally, the system is designed with easy maintenance in mind. The replacement lamps are both user-friendly and readily available, simplifying the upkeep process and ensuring that optimal operation is maintained over time.

In conclusion, the Field Controls UV-16/24 presents a robust solution for enhancing indoor air quality. With its dual UV-C lamp technology, energy efficiency, durable build, safety features, and low maintenance requirements, it stands out as a reliable tool in the ongoing effort to create healthier indoor spaces. Whether for a home or commercial application, the UV-16/24 is a proactive choice for anyone looking to improve their air quality.