1. BATTERIES

The batteries provide the power to operate the machine. The batteries require regular maintenance to keep them operating at peak efficiency.

To get the greatest life from the batteries charge them when their charge level reaches 25%of a full charge. Use a hydrometer to check the charge level.

Do not allow the batteries to remain in a discharged condition for any length of time. Never expose a discharged battery to temperatures below freezing. Discharged batteries will freeze causing cracked case. Do not operate the machine if the batteries are in poor condition or if they have a charge level below 25%, specific gravity below 1.177.

Keep all metallic objects off the top of the batteries, as they may cause a short circuit. Replace worn or damaged cables and terminals.

Check the electrolyte level in each battery cell before and after charging the batteries. Never add acid to the batteries, use water. Do not allow water level to fall below the battery plates. Portions of plates exposed to air will be destroyed. Do not overfill. Keep plugs firmly in place at all times.

!

When servicing machine,

 

avoid contact with acid.

 

 

 

 

 

Batteries emit hydrogen gas.

 

 

 

 

 

 

!

 

 

 

Explosion or fire can result.

 

 

 

 

 

 

 

 

 

 

 

 

Keep sparks and open flame away. Keep covers open when charging.

!

Wear eye protection and

protective clothing when

working with batteries.

!

Charge batteries in a well

ventilated area.

 

BATTERY MAINTENANCE

1.When cleaning the batteries, use a solution of baking soda and water. Do not allow the cleaning fluid to enter the battery cells. Electrolyte will be neutralized.

2.Maintain the proper electrolyte level in each battery cell. If a cell should accidentally overflow, clean immediately.

3.Do not add water until the battery is fully charged.

4.Wipe off the top of the batteries at least once a week.

5.Test battery condition with a hydrometer at least once a week.

MAINTENANCE

6.Ensure that all connections are tight and all corrosion removed.

7.Every 4 to 6 months, remove the batteries from the machine and clean the battery cases and battery compartment.

NOTE: Do not take readings immediately after adding water. If the water and acid are not thoroughly mixed, the reading may not be accurate.

To find the correct specific gravity reading when the temperature of the battery electrolyte is other then 80' F (27' C).

SPECIFIC GRAVITY

BATTERY CONDITION

1.265

 

100% CHARGED

1.225

75% CHARGED

1.190

50% CHARGED

1.155

25% CHARGED

1.120

DISCHARGED

Add (+) to the specific gravity reading

0.004 (4 points), for each 10' F (6' C) above 80' F (27' C) Subtract (-) from the specific gravity reading 0.004 (4 points), for each 10' F (6' C) below 80' F (27' C).

86037580 GLIDE 01/03/07

4-2

 

Page 25
Image 25
Windsor SG36, SG32, SG28, 10052450, 10052460, 10052470 manual Batteries, Battery Maintenance

10052460, SG28, SG32, 10052450, 10052470 specifications

Windsor SG32, 10052470, 10052450, 10052460, and SG36 represent a line of cutting-edge products that have gained recognition for their innovative design and advanced technology. These models are characterized by their user-centric features tailored to enhance efficiency and comfort across various applications.

The Windsor SG32 stands out with its robust build and high-performance capabilities. Featuring a powerful motor, the SG32 is tailored for heavy-duty tasks, ensuring that it can handle extensive cleaning jobs with ease. Its ergonomic design allows for extended use without discomfort, making it a favorite among users who prioritize convenience and efficiency. The integrated dirt sensor technology is a notable feature that optimally adjusts the cleaning power based on surface conditions, guaranteeing thorough cleaning results every time.

Models 10052470, 10052450, and 10052460 share a commonality in their advanced filtration systems. These systems are designed to capture airborne particles effectively, making these models ideal for environments requiring enhanced air quality, such as hospitals and schools. The easy-to-replace filter cartridges reduce maintenance time, allowing users to focus on more critical tasks. Additionally, these models incorporate energy-efficient motors that minimize power consumption while maximizing performance, demonstrating Windsor's commitment to sustainability.

SG36, on the other hand, introduces smart technology with its intuitive touch control panel, allowing users to set operational parameters quickly. This model also features a quiet mode that is perfect for cleaning in noise-sensitive areas without sacrificing performance. The compact design of SG36 enhances maneuverability, making it suitable for tight spaces often found in urban settings.

All these Windsor models are equipped with high-capacity batteries for cordless operation, providing the freedom to clean without being tethered to a power outlet. This feature, coupled with LED indicators that signal battery life, ensures that users can operate with confidence. Maintenance is simplified due to the easily accessible components, meaning downtime for repairs is minimized.

In summary, Windsor SG32, 10052470, 10052450, 10052460, and SG36 boast a range of features aimed at enhancing cleaning efficiency while prioritizing user comfort and sustainability. Each model integrates advanced technologies that cater to various cleaning needs, solidifying Windsor's position as a leader in innovative cleaning solutions.