Windsor SG28, SG32, SG36, 10052450, 10052460 manual Controls, One Touch Switch, Brush Pressure Switch

Models: 10052460 SG28 SG32 10052450 10052470 SG36

1 43
Download 43 pages 33.49 Kb
Page 14
Image 14
3.ONE TOUCH SWITCH

CONTROLS

3.ONE TOUCH SWITCH

This switch controls the scrub brushes and vacuum all in one touch.

To start scrubbing, press the one touch switch. The brush drive motors will turn on, the scrub deck will lower to the "light scrub" position, the solution will flow at “two bars” rate, the squeegee will lower and the vacuum will turn on. The information display window will show which functions are operating. If the direction control pedal is in the neutral position for more than two seconds the brushes and solution flow will stop. If the one touch switch is activated without brushes installed, the brush motors will stop, the scrub deck will rise, and the brush pressure indicator will display error code 9000. To stop scrubbing, press the one touch switch. The brush drive motors will turn off, the scrub deck will raise the solution flow will stop, the squeegee will raise after a 15 second delay, and the vacuum motor will turn off. This delay is to clear the vacuum hose of recovered solution.

INFORMATION DISPLAY

4.BRUSH PRESSURE SWITCH

This switch controls the amount of brush pressure to the floor. There are 5 different pressure settings. To decrease the amount of down pressure, press the top of the brush pressure switch (-). To increase the amount of down pressure, press the bottom of the brush pressure switch (+). The information display screen will show the amount of pressure.

NOTE: Press switch and hold momentarily each time to change brush pressure.

INFORMATION DISPLAY

LESS PRESSURE

MORE PRESSURE

3-7

86037580 GLIDE 01/03/07

 

Page 14
Image 14
Windsor SG28, SG32, SG36, 10052450, 10052460, 10052470 manual Controls, One Touch Switch, Brush Pressure Switch