Field Controls UV-12 Maintenance, VI. Lamp Replacement Procedure, VII. Troubleshooting Guide

Page 7

V.MAINTENANCE

1.Inspect and clean lamp at least every 6 months.

2.Replace your UV-Aire™ Air Purifying System lamp once a year to maintain the lamps maximum output intensity. The lamp should operate continuously for maximum lamp life and light effectiveness.

VI. LAMP REPLACEMENT PROCEDURE

VERY IMPORTANT: Turn switch on unit to ‘OFF’ position and unplug unit from outlet.

1.Loosen the cover screw on the side of the unit and open cover.

2.Unplug ballast plug from end of lamp.

3.Loosen the wing nut on swivel bracket and rotate the bracket clockwise.

4.Slide lamp out carefully.

NOTE: When replacing the lamp, always wipe off lamp before installing.

5.Insert the lamp through the mounting hole and secure the lamp by rotating the swivel bracket counter-clockwise into position and secure by tightening wing nut. Be careful not to over tighten the wing nut.

NOTE: UV lamps contain a small amount of mercury, like a typical fluorescent lamp. Check with your local waste management authority for local disposal or recycling requirements. According to the EPA’s Universal Waste Rule, these types of lamps may be disposed of into household waste.

6.Attach the ballast plug onto the end of the lamp.

7.After replacing lamp, make sure a new Lamp Replacement Label (supplied with lamp replacement) is applied to the housing and dated with the date of installation.

VII. TROUBLESHOOTING GUIDE

1.If the lamp does not light up, replace the lamp.

2.If the lamp still does not light up after replacing the lamp, replace ballast.

VIII. REPLACEMENT PARTS LIST

 

MODEL

 

LAMP

BALLAST

 

 

(Field Controls Part Number)

(Field Controls Part Number)

 

 

 

 

UV-12

46365401

46365508

 

 

 

 

 

UV-18

46365402

46365509

 

 

 

 

 

For replacement parts, contact your local heating service company. Any questions, please contact Field Controls at:

Phone: 252-522-3031

Fax: 252-522-0214

Email: sales@fieldcontrols.com

WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your

hands.

Page 7

Image 7
Contents Items Included in KIT Safety ConsiderationsIndication for USE III. InstallationII. General Information For flex duct applications, refer to on Hands Location to reduce any direct viewing of light. See Figure IV. Bulb Mounting Bracket Selection UV-Aire ConfigurationsVIII. Replacement Parts List MaintenanceVI. Lamp Replacement Procedure VII. Troubleshooting GuideIX. Flex Duct Installation Limited Warranty

UV-12, UV-18 specifications

Field Controls UV-12 and UV-18 are advanced ultraviolet (UV) air purification systems designed to enhance indoor air quality by effectively targeting and neutralizing airborne pathogens. These models utilize cutting-edge technology to provide a safer and healthier environment in residential and commercial spaces.

One of the primary features of both the UV-12 and UV-18 units is their powerful UV-C light technology. This germicidal UV light works at a wavelength of 254 nanometers, effectively disrupting the DNA and RNA of microorganisms, including bacteria, viruses, and mold spores. By doing so, these systems render the pathogens inactive, significantly reducing their ability to reproduce and cause illness.

The UV-12 is suitable for smaller HVAC systems, making it an ideal choice for compact spaces or homes. It boasts a dual-lamp design that offers enhanced purification capacity without compromising energy efficiency. The UV-18, on the other hand, is designed for larger HVAC systems, delivering increased output for areas with higher air volume and contamination loads. The larger unit accommodates more extensive applications without sacrificing performance.

A significant advantage of the Field Controls UV systems is their low-maintenance design. The replacement UV lamps are designed to last up to 18 months of continuous operation, ensuring consistent performance without frequent interventions. Moreover, the installation process is straightforward, as both models can be easily integrated into existing HVAC systems, allowing for minimal disruption to the user’s daily operations.

Another critical aspect of the UV-12 and UV-18 is their ability to operate silently, providing air purification without noise distractions. This characteristic makes them ideal for use in environments where quiet operation is essential, such as homes, offices, and healthcare facilities.

In addition to their germicidal capabilities, the Field Controls UV systems also help in reducing unpleasant odors. By targeting VOCs (volatile organic compounds) and other airborne contaminants, they contribute to a fresher and more pleasant indoor atmosphere.

Overall, the Field Controls UV-12 and UV-18 air purification systems represent a solid investment for those seeking to improve indoor air quality. Their innovative UV technology, ease of maintenance, and silent operation make these units an excellent choice for maintaining a healthy living or working environment. The combination of efficacy and user-friendly design ensures that users can enjoy peace of mind while effectively combating harmful airborne pathogens.