Field Controls 24v manual Independent Lab Testing, Attack the Source

Page 8

UV-AIRE®Air Purification System

Independent Lab Testing

For many years, ultraviolet light has proven effective in sterilizing medical equipment, purifying water, and processing food. Currently, the use of UV lights is gaining industry acceptance in HVAC applications. Microbe Management, Inc., a testing agency in

Greenville, NC, has conducted three separate tests to examine UV’s effect on indoor air quality. The test results conclude that UV is an integral part of a whole house approach to improving Indoor Air Quality.

Attack the Source

While experts disagree on the root causes of many IAQ

The air conditioning coil must be addressed since it is a

problems, there is consensus that stopping problems at

natural breeding ground for molds, which thrive in a

the source is crucial to long-term air quality

 

dark, moist environment. Familiar with the rank smell

improvement. First, the homeowner must

 

 

generated when switching from air

eliminate any unwanted sources of

 

 

conditioning to heat mode? That is the

moisture in the home, such as roof

 

 

smell of mold and bio-film burning off

leaks, drainage problems, and crawl

 

 

the coil. Whenever the blower is

space moisture.

 

 

engaged, mold spores from

 

 

 

 

contaminated A-coils are released

Note: Crawl space moisture can

 

 

 

into the ductwork and distributed

be addressed with the EL-1

 

EL-1 Eliminator

throughout the building. These spores

Eliminator Foundation Vent Fan.

 

then seek alternative surfaces in other

 

Foundation Vent Fan

 

 

 

 

parts of the home to breed and multiply.

 

 

 

 

Surface Test: UV Kills and Prevents Mold on A-Coils

A specific test was designed to determine UV’s effectiveness in treating mold on coil surfaces. The test simulated the damp, dark settings where A-coils are found.

In this study “We took a standard A-coil, sterilized it, introduced two kinds of mold, and then placed it in a controlled, moisture-laden environment,” says Bernard Kane, of Microbe Management. “We created two separate chambers in our lab. One chamber was bathed in UV light. The other was not.”

The results were dramatic and conclusive. The side of the A-coil that was exposed to the ultraviolet light was clean and clear of mold growth. Mold continued to grow

unabated on the side without UV. Subsequently, the contaminated side was bathed in UV light and the mold was eradicated. Kane summarized the

results: “ProperlySurface Test Results positioning a UV lamp

over the A-coil in a residential or commercial air conditioning system can eliminate surface mold on the coil and prevent future mold growth as well.”

Airborne Testing: Single Pass and Cumulative Tests

Bacteria and viruses are introduced into the building by its occupants and often cannot be controlled at the source. Therefore, it is important to attack these airborne invaders early and often, before they have an opportunity to multiply. The single pass test proves that UV effectively kills these airborne microorganisms in the duct.

Since HVAC systems typically re-circulate the air 40-75 times per day, a multi-pass, cumulative test was also conducted. Results demonstrate that repeated, multi- pass exposure to UV light dramatically reduces the concentration of bacteria and viruses throughout

the home.1

1.Efficiency of Bacterial Disinfection by a Duct-mounted UV-Aire®Air Purifier: by Microbe Management

8

Image 8
Contents Air Purification Whole House Solution UV-AIREAir Purification SystemSun Nature’s Outdoor Air Purifier Eliminate Moisture ProblemsIndoor Air High Concentrations Biological Contaminants Facts About Indoor Air Facts About UVIndoor Air Treatment With UV Filter Systems Alone Dont Solve the ProblemHow The In-duct UV-Aire Works UV-12, UV-18, UV-28, UV-12HP, UV-18HP, UV-28HP UV-18XUV-12C, UV-18C, UV-28C UV-12E, UV-18E, UV-28EUV-AIREAir Purification System Portable Models Independent Lab Testing Airborne Testing Single Pass and Cumulative TestsAttack the Source Surface Test UV Kills and Prevents Mold on A-CoilsConclusion UV Is An Effective Part of Whole House Solution Single Pass Test UV Deadly for Airborne MicrobesLamp Intensity Bird Flu Virus Avian FluInstallation Installation OptionsModels & Specifications Replacement Parts