Filters

All EL195UH filters are installed external to the unit. Filters should be inspected monthly. Clean or replace the filters when necessary to ensure proper furnace operation. Re- placement filters must be rated for high velocity airflow. Table 1 lists recommended filter sizes.

A filter must be in place when the unit is operating.

TABLE 1

Furnace

Filter Size

Cabinet Width

Side Return

Bottom Return

 

 

 

 

17−1/2"

16 X 25 X 1 (1)

16 X 25 X 1 (1)

 

 

 

21"

16 X 25 X 1 (1)

20 X 25 X 1 (1)

 

 

 

24−1/2"

16 X 25 X 1 (2)

24 X 25 X 1 (1)

Maintenance

A licensed professional service technician (or equivalent) should inspect the complete system each season (heating and cooling). The following maintenance procedures should only be conducted by a licensed professional ser- vice technician (or equivalent). Do not attempt to service

the unit in any way.

WARNING

ELECTRICAL SHOCK, FIRE,

OR EXPLOSION HAZARD.

Failure to follow safety warnings exactly could result in dangerous operation, serious injury, death or property damage.

Improper servicing could result in dangerous opera- tion, serious injury, death, or property damage. Before servicing, disconnect all electrical power to furnace.

When servicing controls, label all wires prior to dis- connecting. Take care to reconnect wires correctly. Verify proper operation after servicing.

Venting System

WARNING

Asphyxiation Hazard

The exhaust vent for this furnace must be leak−free and must be securely connected to the furnace flue collar at all times.

For your safety and to fulfill the terms of the limited warranty, a licensed professional service technician (or equivalent) must annually inspect this furnace and its vent system.

Annually (before heating season) inspect furnace venting system, vent cap, heat exchanger, and burners for corro- sion, deterioration, or deposits of debris. Remove any ob- structions.

Inspect the furnace for obvious signs of deterioration. Inspect the furnace venting system to make sure it is in place, physically sound, and without holes, corrosion, or blockage.

Vent pipe must be clear and free of obstructions and must slope upward away from the furnace.

Inspect the furnace return air duct connection to ensure duct is sealed to the furnace and terminates outside the space containing the furnace.

Inspect the physical support of the furnace to guarantee that it is sound without sagging, cracks or gaps around base and it maintains seal between base and support.

Inspect the condensate drain and trap for leaks and cracks. The drain and trap must also be cleaned and the trap must be filled with water.

During a seasonal check the service technician will con- duct a combustion analysis. The technician will also in- spect the indoor blower, burner flames, electrical connec- tions and the venting system.

Blower

Check the blower wheel for debris and clean if necessary. The blower motors are prelubricated for extended bearing life. No further lubrication is needed.

WARNING

The blower access panel must be securely in place when the blower and burners are operating. Gas fumes, which could contain carbon monoxide, can be drawn into living space resulting in personal inju- ry or death.

Burner Flame

CAUTION

To ensure proper operation, a licensed professional service technician (or equivalent) should check the burner flame and conduct a combustion analysis annually.

Electrical

1 − Check all wiring for loose connections.

2 − Check for the correct voltage at the furnace (furnace operating).

3 − Check amp−draw on the blower motor.

Motor Nameplate__________Actual__________

Page 5

Image 5
Contents EL195UH Series EL195UH Parts Identification Safety Instructions Carbon monoxide gas is invisible, odorless and toxic Start−Up & Operation InformationFilters MaintenancePlanned Service Service ReminderSafety Precautions Repair Parts List EL195DF Series EL195DF Parts Identification Safety Instructions Start−Up & Operation Information Furnace Filter Size Cabinet Width 17−1/2 16 x 25 x 1 21−1/2 Service Reminder Repair Parts List

EL195UH SERIES, Gas Furnace specifications

The Lenox EL195UH Series gas furnace is an efficient and reliable heating solution designed to provide exceptional comfort in residential settings. With a focus on performance, efficiency, and advanced technology, this furnace has become a popular choice among homeowners looking for a dependable heating system.

One of the standout features of the EL195UH Series is its high efficiency rating. With an Annual Fuel Utilization Efficiency (AFUE) rating of up to 95%, this gas furnace converts a significant portion of fuel into heating energy, minimizing waste and reducing energy costs. This efficiency not only benefits homeowners financially but also contributes positively to the environment by lowering greenhouse gas emissions.

The furnace incorporates a two-stage gas valve, which allows for greater temperature control and comfort. This technology enables the furnace to operate at a lower heating capacity during milder conditions, ensuring consistent temperatures while saving energy. When the temperatures drop, the furnace can ramp up to its higher capacity, providing the necessary warmth quickly and efficiently.

Another key characteristic of the Lenox EL195UH is its quiet operation. Equipped with a variable-speed blower motor, this furnace operates more quietly than traditional models. The motor adjusts its speed according to the heating demands, which not only enhances comfort through more even air distribution but also reduces noise levels in the home.

The EL195UH Series is designed for durability and longevity. It features a robust heat exchanger, constructed from high-quality materials that withstand the rigors of constant heating and cooling. Additionally, the furnace comes with a limited lifetime warranty on the heat exchanger, providing peace of mind to homeowners regarding their investment.

To enhance convenience, the EL195UH Series is compatible with smart home technology. Homeowners can integrate their furnace with smart thermostats, allowing for remote control and programming, which optimizes heating schedules based on lifestyle preferences.

In summary, the Lenox EL195UH Series gas furnace combines high efficiency, advanced technology, and quiet operation to create a top-tier heating solution. With its two-stage gas valve, durable construction, and compatibility with smart technology, this furnace is designed to meet the needs of modern homeowners while providing comfort and reliability throughout the heating season. Whether for new installations or as a replacement for an older system, the EL195UH Series stands out as a premier choice in home heating solutions.