Bryant 367AAN manual Filtering OUT Trouble, Performing Routine Maintenance

Page 6

2.Turn off all electrical power to the appliance. (See Fig. 9.)

9

3.Close the oil supply valve. (See Fig. 10).

10

4.If applicable, turn off water sup- ply to humidifier.

5.If furnace blower will be neces- sary for cooling system, remem- ber to turn electric power back on when needed for air condi- tioning.

6.If the furnace is being shut down because of a malfunction, call your dealer as soon as possible.

ALWAYS KEEP MAIN OIL VALVE TURNED OFF IF BURNER IS SHUT DOWN FOR AN EXTENDED PERIOD OF TIME.

PERFORMING ROUTINE MAINTENANCE

With proper maintenance and care, your furnace will operate economi- cally and dependably. Instructions for basic maintenance follow. How- ever, before beginning maintenance, follow these safety precautions:

!WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal in- jury due to electrical shock.

Turn off all electrical power to furnace before performing any maintenance or service on unit.

11

12

!CAUTION

CUTS AND ABRASION HAZARD

Failure to follow this caution may result in minor personal injury.

Although special care has been taken to minimize sharp edges, be extremely careful when handling parts or reaching into the furnace.

FILTERING OUT

TROUBLE

Dirty air filters will cause a loss of airflow in your duct system. When excessive loss of airflow occurs, the furnace may cycle on its safety controls. If this condition is left

6

unattended, the furnace will even- tually lock out. It is recommended that the furnace air filters be checked every 3 or 4 weeks and cleaned or replaced as necessary.

!CAUTION

UNIT OVERHEAT HAZARD Failure to follow this caution may result in damage to the furnace blower motor, over- heat the heat exchanger and reduce the efficiency.

Never operate your furnace without the air filters in place.

The air filters are located in the blower compartment installed in an internal filter rack which is pro- vided as standard equipment with furnace. (See Fig. 2.) To inspect, clean, and or replace air filters, fol- low these steps:

1.Turn off electrical supply to fur- nace. (See Fig. 11.)

2.Remove blower access door in rear of furnace. (See Fig. 13.) Lift door up, then out using han- dle on blower access door.

1

2

13

3.Remove air filters from furnace.

a.Remove filter resting in filter rack at an angle in front of blower first. Slide filter back to clear filter rack ends then lift up and out of filter rack and blower compartment. (See Fig. 14.)

2

1

14

Image 6
Contents Model 367AAN OIL Furnace Welcome to a NEW Generation of Comfort Installation DataAccessories Model 367AAN LOW-BOY FurnaceFurnace Components Safety Considerations For Your SafetyImportant Facts Shutting Down Your Furnace Steps for Starting Your FurnaceElectrical Shock Hazard High Voltage AT Igniter Performing Routine Maintenance Filtering OUT TroubleCHECK-UP Checklist Beforeyou Request a Service CallFurnace AIR Filter Table Cancels OM16-8 OM16-13 Catalog No
Related manuals
Manual 4 pages 45.11 Kb

367AAN specifications

The Bryant 367AAN is a highly efficient and reliable air conditioning unit designed for both residential and commercial applications. This model stands out in the market due to its impressive performance, advanced technologies, and energy-saving features that cater to varying climate conditions.

One of the principal features of the Bryant 367AAN is its SEER (Seasonal Energy Efficiency Ratio) rating, which can reach up to 17. This means that the unit operates efficiently, providing significant energy savings over time while delivering optimal cooling performance. With a high SEER rating, homeowners can enjoy a comfortable indoor environment without worrying about skyrocketing energy bills.

The 367AAN model is equipped with a two-stage compressor, which allows it to adjust its cooling capacity based on the current temperature demands. This feature promotes a consistent and comfortable indoor climate by ensuring that the system does not operate at full capacity when it is not needed. As a result, this air conditioning unit operates quietly while delivering consistent performance, making it an excellent choice for maintaining indoor comfort.

Another notable technology in the Bryant 367AAN is its use of environmentally friendly refrigerant, R-410A. This modern refrigerant is designed to minimize ozone depletion and is more efficient than older refrigerants. The use of R-410A not only makes this unit eco-friendly but also allows it to deliver high-efficiency cooling performance that meets stringent environmental standards.

Additionally, the 367AAN features a sound-dampening system, which includes a specially designed compressor compartment. This design minimizes operational noise, ensuring that the unit runs quietly, making it suitable for residential areas where noise can be a concern. Homeowners can enjoy peace and quiet while their air conditioning system is operating.

Furthermore, reliability is a key characteristic of the Bryant 367AAN, built with durable materials that can withstand various weather conditions. The unit is also equipped with a factory-installed filter drier and a protective coating that safeguards against corrosion, thus enhancing its longevity and performance.

In conclusion, the Bryant 367AAN air conditioning unit is a well-rounded choice for anyone seeking energy-efficient cooling with advanced technology and a quiet operation. Its two-stage compressor, environmentally friendly refrigerant, and robust design make it a dependable option for maintaining comfort in any environment. Whether for residential or commercial use, the 367AAN is sure to deliver throughout its service life.