Bryant 331JAV, 330JAV instruction manual 324459-101 REV. D

Page 8

CONNECTION DIAGRAM

LS

FRS2

LPS NOTE #8

 

RED

 

 

 

ORN

 

 

 

 

 

 

 

GRY

 

 

HPS

BRN

HI

 

 

 

 

 

 

 

 

 

 

YEL

 

 

 

 

 

 

 

 

 

P

 

 

 

 

RED

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LGPS

 

 

 

 

 

BRN

 

 

 

 

BLU

 

GV

 

 

 

 

 

 

 

 

DSS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M

 

 

 

 

 

 

 

 

ORN

 

 

 

 

 

 

 

 

 

 

 

GRN/YEL

 

 

 

 

GRN/YEL

 

 

 

 

RED

 

#8NOTE

USED)(WHEN

FSE

 

 

 

 

IDM

 

L1

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FRS1

 

 

 

 

 

 

 

HSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUSED DISCONNECT

(WHEN USED)

 

ALS1

 

 

 

 

 

 

 

 

 

GRN/YEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH (WHEN REQ’D)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ILK

JB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE #1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SET-UP

 

 

 

 

(WHEN USED)

 

WHT

 

GRY

 

 

RED

 

 

 

 

 

 

 

 

 

 

HEAT

 

 

 

 

ORN

NOTE #6

 

 

 

 

PL6

 

 

WHT

 

 

 

L2

WHT

 

FU2

 

SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

 

 

 

 

 

 

 

1

2

 

 

 

 

 

 

GND

 

 

 

 

1

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NORM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALS2

YEL

 

 

 

 

 

BLK

 

BLK

WHT

 

 

 

 

 

 

HI HT *

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

LO HT

ON OFF

ON OFF

ORN

 

 

 

 

 

 

 

WHT

1

2

3

PL3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLOWER-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF DELAY SWITCH

 

 

 

 

 

WHT

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

(SEC.)

3

 

4

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90 SEC

*

 

 

 

 

 

 

 

 

 

 

PL2

 

BLK

 

 

 

 

 

 

 

 

 

135 SEC

 

 

 

 

 

 

 

 

 

1

 

WHT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

180 SEC

 

 

 

2-STAGE

 

 

 

 

 

2

8

 

 

 

 

 

 

 

 

 

 

 

 

225 SEC

 

 

 

 

 

BLU

YEL

 

 

 

 

 

 

 

 

 

 

 

 

 

ON OFF

ONOFF CONTROL

 

 

 

3

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FURNACE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FACTORY

SETTINGS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

1

 

 

 

BLU

BRN

GRY

PR1

PR2

 

 

MED HI

 

YEL

 

 

 

GRN/YEL

 

 

 

 

HIGH-HEAT ONLY

 

 

GRN/YELP1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHT

 

CAP

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

L1

L2

 

 

 

 

 

 

 

 

 

 

WHT

 

 

 

 

 

*

 

ORN

 

 

 

COMMON

 

 

 

 

NOTE #4

BRN

BRN

 

 

 

 

 

 

 

 

 

 

HI-COOL

 

 

 

 

 

 

 

 

 

4

 

BLOWER-OFF DELAY

RED

 

 

 

 

 

 

COM

 

WHT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRAN

 

 

3

 

BLOWER-OFF DELAY

RED

 

 

 

 

HI-GAS EAC-2

 

 

HI

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

LOW-HEAT ONLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

OFF

 

 

 

321

 

12

LO-GAS

EAC-1

 

NOTE #15

MED

ORN

 

 

 

RED

BLU

 

 

 

 

 

 

 

TWIN

 

 

10

HEAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MED LO

 

BLU

 

 

 

 

 

 

 

 

 

 

 

 

 

TEST

TJ

 

11

SPARE

SPARE

 

 

LO

 

BLWM

 

 

 

 

 

 

 

 

 

 

M

 

 

 

 

 

 

 

RED

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

SEC1

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

LED S

 

 

 

 

 

BLU

 

 

 

 

 

 

 

 

 

 

 

W2

Com W/W1

Y/Y2 R

G HUM

 

 

 

SEC2

FU1

 

 

 

 

 

 

 

 

 

 

 

 

 

24V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEGEND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO 115VAC FIELD

 

 

 

 

SCHEMATIC DIAGRAM

(NATURAL GAS & PROPANE)

EQUIPMENT

 

 

 

 

 

 

 

 

DISCONNECT SWITCH

 

NOTE #1

 

 

 

 

 

 

GROUND

 

 

 

 

 

 

 

 

 

ILK

 

 

 

 

 

 

 

 

 

 

 

BHI / LOR

 

LO-GAS-HEAT

 

 

 

 

 

 

 

 

 

 

LO

 

 

L2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MED LO

 

 

 

BLWM

 

 

 

BHT / CLR

 

HI-GAS-HEAT

 

 

 

 

 

 

 

 

NOTE #15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L1

BLWR

 

 

 

 

SPARE

MED

 

HI

COM

 

 

 

 

HI-COOL

SPARE

MED HI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE #4

BRN

BRN

 

 

 

 

 

COMMON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HSIR

 

EAC-1

EAC-2

 

 

 

 

 

 

CAP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PL2

3

PL6

1

HSI

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IHI / LOR

 

 

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LO

 

 

IDR

 

 

 

 

 

 

4

PL3

2

HI

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

7

 

3 COM

IDM

 

PR1

 

 

 

PR2

 

 

8

 

 

 

 

 

115VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FU1

SEC1

TRAN

SEC2

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24VAC

 

 

HPSR

5 N/A

 

 

 

 

NOTE #5

 

 

 

 

 

 

6

N/A

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

12 N/A

 

FRS2

 

 

HUM

 

 

MGVR-2

 

2

FRS1

 

 

 

 

 

 

 

 

 

 

 

LS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 (WHEN USED)

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

9

 

ALS2

ALS1

 

TWIN

 

 

 

 

 

 

 

 

 

TWINNING

 

 

 

 

 

 

 

 

TEST

 

 

 

6

 

 

 

 

 

 

S

JUMPER

 

 

PL1

 

 

 

DSS

 

 

 

TJ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W/W1

 

NOTE #8 LPS

 

 

M

5

(WHEN USED)

 

LGPS

 

 

SW1

 

NOTE #8

 

4

 

ALS1

AUXILIARY LIMIT SWITCH, OVERTEMP. MANUAL RESET, SPST (N.C.)

ALS2

AUXILIARY LIMIT SWITCH, OVERTEMP. AUTO RESET, SPST (N.C.)

BHI / LOR

BLOWER MOTOR SPEED CHANGE RELAY, SPDT

BHT / CLR BLOWER MOTOR SPEED CHANGE RELAY, SPDT

BLWM

BLOWER MOTOR, 4 or 5 -SPEED, PERMANENT-SPLIT-CAPACITOR

BLWR

BLOWER MOTOR RELAY, SPST (N.O.)

CAP

CAPACITOR

CPU

MICROPROCESSOR AND CIRCUITRY

DSS

DRAFT SAFEGUARD SWITCH (N.C.)

EAC-1

ELECTRONIC AIR CLEANER CONNECTION (115 VAC, 1 AMP MAX.)

EAC-2

ELECTRONIC AIR CLEANER CONNECTION (COMMON)

FRS1

FLAME ROLLOUT SWITCH OVERTEMP. MANUAL RESET, SPST (N.C.)

FRS2

FLAME ROLLOUT SWITCH OVERTEMP. MANUAL RESET, SPST (N.C.)

FSE

FLAME-PROVING SENSOR ELECTRODE

FU1

FUSE, 3 AMP, AUTOMOTIVE BLADE TYPE, FACTORY INSTALLED

FU2

FUSE, FIELD INSTALLED

GV

GAS VALVE, REDUNDANT LOW-HEAT OPERATORS, 2-STAGE

HPS

HIGH-HEAT PRESSURE SWITCH, SPST (N.O.)

MGVR

MAIN GAS VALVE RELAY, DPST (N.O.)

 

-1 = VALVE

-2 = HUMIDIFIER

PL1

12-CIRCUIT CONNECTOR

PL2

9-CIRCUIT CONNECTOR

PL3

3-CIRCUIT IDM CONNECTOR

PL6

2-CIRCUIT HSI CONNECTOR

SW1

HIGH-HEAT-ONLY SWITCH, SPST (MANUAL)*

SW2

LOW-HEAT-ONLY SWITCH, SPST (MANUAL)*

SW3 & 4

BLOWER-OFF DELAY SETTING SWITCHES,

 

SPST (MANUAL)*

 

TJ

TWINNING JUMPER, SPDT FOR MAIN OR

 

SECONDARY STATUS (MANUAL CHANGE OVER)

TRAN

TRANSFORMER-115VAC/24VAC

TWIN/TEST

1-CIRCUIT TWINNING BUSS CONNECTOR,

 

ALSO STATUS CODE RECALL

JUNCTION

TERMINAL

CONTROL TERMINAL

 

W2

CPU

 

HPS

 

 

 

 

 

 

MGVR-1

 

P

HI

 

 

1

M

 

 

 

 

 

 

Y/Y2

10

C

GV

 

 

 

 

 

 

 

 

NOTE#7

 

 

 

G

 

 

 

 

 

 

7

 

FSE

 

 

8 N/A

 

 

 

 

COM

11 N/A

 

 

 

NOTES:

SW4

SW3 SW2

 

 

 

 

 

 

 

 

HPSR

HIGH-HEAT PRESSURE SWITCH RELAY, SPST (N.C.)

HSI

HOT-SURFACE IGNITER (115 VAC)

HSIR

HOT-SURFACE IGNITOR RELAY, SPST (N.O.)

HUM

24VAC HUMIDIFIER CONNECTION (0.5 AMP. MAX.)

IDM

INDUCED DRAFT MOTOR, 2-SPEED, SHADED-POLE

IDR

INDUCER MOTOR RELAY, SPST (N.O.)

IHI / LOR

INDUCER MOTOR SPEED CHANGE RELAY, SPDT

ILK

BLOWER DOOR INTERLOCK SWITCH, SPST (N.O.)

JB

JUNCTION BOX

LED

LIGHT-EMITTING DIODE FOR STATUS CODES

LGPS

LOW GAS-PRESSURE SWITCH, SPST (N.O.)

LPS

LOW-HEAT PRESSURE SWITCH, SPST (N.O.)

LS

LIMIT SWITCH, OVERTEMPERATURE-AUTO RESET, SPST (N.C.)

FACTORY POWER WIRING (115VAC)

FACTORY CONTROL WIRING (24VAC) FIELD POWER WIRING (115VAC)

FIELD CONTROL WIRING (24VAC) CONDUCTOR ON CONTROL FIELD WIRING SCREW TERMINAL FIELD GROUND

EQUIPMENT GROUND

FIELD SPLICE

PLUG RECEPTACLE

1.Use only copper wire between the disconnect switch and the unit.

2.If any of the original wire, as supplied, must be replaced, use the same or equivalent type wire.

3.Inducer (IDM) and blower (BLWM) motors contain internal auto-reset thermal overload switches.

4.Blower motor speed selections are for average conditions. See Installation Instructions for details on optimum speed selection.

5.Replace only with a 3-AMP fuse.

6.Auxiliary limit switches (ALS1 & 2) used on some horizontal and some downflow models.

7.This wire must be connected to furnace sheet metal for control to prove flame.

8.Factory connected when LGPS not used.

9.Symbols are an electrical representation only.

10.BLOWER-ON DELAY: Gas heating 45 seconds, Cooling/Heat Pump 2 seconds.

11.Cooling/Heat Pump BLOWER-OFF DELAY is 90 seconds.

12.IGNITION-LOCKOUT will occur after four consecutive unsuccessful trials-for-ignition. Control will automatically reset after three hours.

13.Control must be grounded at pin 10 of 12-pin connector.

14.NA - Not Applicable

15.Spare terminal and wire not available on some applications. Insulate connector if not available.

324459-101 REV. D

A01365

Fig. 11—Unit Wiring Diagram

Image 8
Contents Table of Contents Safety ConsiderationsElectrostatic Discharge ESD Precautions Procedure Care and MaintenanceCleaning AND/OR Replacing AIR Filter IntroductionDownflow Filter Arrangement II. Blower Motor and WheelIII. Cleaning Heat Exchanger Speed SelectorPosition of Ignitor to Burner IV. Electrical Controls and Wiring Wiring Diagrams Troubleshooting324459-101 REV. D Service Start Service Training
Related manuals
Manual 4 pages 14.45 Kb

330JAV, 331JAV specifications

The Bryant 331JAV is a remarkable air conditioning unit that epitomizes efficiency, reliability, and advanced technology. Designed for residential use, the 331JAV series stands out with its Energy Star certification, ensuring that homeowners can enjoy optimal cooling while minimizing their energy consumption. This unit is particularly appealing to environmentally conscious individuals looking to reduce their carbon footprint without sacrificing comfort.

One of the key features of the Bryant 331JAV is its two-stage cooling system. This technology allows the unit to operate at varying speeds, adjusting its performance based on the home's cooling needs. By running at a lower speed for extended periods, the unit can maintain a consistent temperature with less energy consumption. This not only enhances comfort but also contributes to lower electricity bills.

In terms of design, the Bryant 331JAV boasts a compact and modern look, making it suitable for various home aesthetics. Its durable cabinet is designed to withstand harsh weather conditions, ensuring longevity and reliable performance. Additionally, the unit is equipped with a quiet operation system, which helps to maintain a peaceful indoor environment while cooling.

The Bryant 331JAV also incorporates advanced refrigerant technologies. It utilizes R-410A refrigerant, which is known for its efficiency and safety, as it does not harm the ozone layer. This focus on eco-friendly materials further underscores Bryant's commitment to sustainability.

Connectivity is another notable characteristic of the Bryant 331JAV. The unit is compatible with smart thermostats, allowing homeowners to control their cooling systems remotely through smartphones or other devices. This feature not only adds convenience but also enhances energy management, as users can adjust settings according to their schedules.

Furthermore, the unit has multiple capacity options, ensuring that it can be tailored to meet the specific needs of different homes. It is also designed for easy installation and maintenance, with accessible components that simplify service tasks.

Overall, the Bryant 331JAV is an exemplary choice for any homeowner looking to invest in a cutting-edge air conditioning system. With its combination of energy efficiency, advanced technology, and user-friendly features, it represents a significant leap forward in residential climate control solutions.