Bryant 345MAV manual Steps for Starting Your Furnace

Page 5

STEPS FOR STARTING YOUR FURNACE

1.Set your room thermostat to the low- est temperature setting. (See Fig. 6.)

®

6

CL

O

S

E

7

8

2.Close the external manual gas valve. (See Fig. 7.)

3.Turn off electrical supply to the fur- nace. (See Fig. 8.)

4.Remove the main furnace door. (See Fig. 9.)

5.Gas valve will have EITHER a con- trol switch or control knob to turn OFF or ON. Turn control switch or knob on the gas valve to the OFF position and wait 5 minutes. (See Fig. 10 or 11.) Then smell for gas, including near the floor. If you smell gas, STOP! Follow operating instructions on main furnace door.

6.After waiting 5 minutes, turn con- trol switch or knob on the gas valve to the ON position.

(See Fig. 12 or 13.)

7.Replace main furnace door. (See Fig. 14.)

8.Turn on electrical supply to the fur- nace and wait 1 minute.

(See Fig. 15.)

9.Open the external manual gas valve. (See Fig. 16.)

10.Set room thermostat to a tem- perature slightly above room temperature. This will auto- matically signal the furnace to start.

11.When the furnace receives the start signal, the inducer is started. When the pressure switch verifies that there is sufficient combustion air, the control energizes the hot surface ignitor. After the hot surface ignitor is heated for 17 sec, the gas valve permits gas to flow to the main burn- ers. After ignition and a time delay of 60 sec, the furnace blower starts.

 

 

9

 

M

1

O

P

3

F

 

 

 

F

C

2

 

 

 

 

ON

 

 

 

10

F

OF

11

5

 

M

1

O

P

3

F

 

 

 

F

 

2

 

C

 

 

 

ON

 

 

 

12

ON

13

NOTE: If the burners fail to ignite after 4 attempts, the furnace control system will lock out. If lockout occurs, main burners fail to light, or blower does not come on, shut down the furnace and call your dealer for service.

12.Set your thermostat to the temper- ature that satisfies your comfort requirements.

SUGGESTION: Setting the ther- mostat back a few degrees and compensating for the difference with warmer clothing can make a big difference in your fuel con- sumption on extremely cold days. The few degrees at the top of your thermostat “comfort level” are the most costly degrees to obtain.

When room temperature drops below the temperature selected on the thermostat, the furnace will be switched on automatically. When room temperature reaches the degree selected on the thermo- stat, the furnace will be switched off automatically.

Some thermostats have a FAN mode with 2 selections, AUTO and ON. When thermostat is set to AUTO, the furnace blower cycles on and off, controlled by the thermostat. In ON mode, the furnace blower runs continu- ously. This keeps the temperature level in your home more evenly balanced. It also continuously fil- ters the indoor air.

Image 5
Contents Model 345MAV Condensing GAS Furnace Model 345MAV Furnace Welcome to a NEW Generation of ComfortModel 345MAV Furnace Shown in Upflow Position Furnace ComponentsStarting Your Furnace Safety ConsiderationsImportant Facts Steps for Starting Your Furnace Filtering OUT Trouble Performing Routine MaintenanceShutting Down Your Furnace AIR Filter Located in Side AIR Filters Located in BottomDON’T Forget Your Furnace Reinstall burner enclosure frontBefore YOU Request a Service Call CHECK-UP ChecklistFor Insufficient Airflow If Furnace Fails to OperateSee Fig Model 345MAV Diagnostic Chart
Related manuals
Manual 40 pages 58.13 Kb Manual 12 pages 34 Kb

345MAV specifications

The Bryant 345MAV is a premier choice in the realm of residential heating and cooling systems, encapsulating advanced technologies, high efficiency, and remarkable performance. Designed for homeowners seeking reliability and comfort, this model exemplifies modern HVAC (Heating, Ventilation, and Air Conditioning) innovations.

One standout feature of the Bryant 345MAV is its impressive energy efficiency. With a high SEER (Seasonal Energy Efficiency Ratio) rating, it operates at peak levels while consuming less energy. This not only reduces utility bills but also supports environmental sustainability, making it an ideal selection for eco-conscious consumers. The model employs variable-speed technology, which allows the system to adjust its output based on current heating and cooling needs. As a result, it provides consistent indoor comfort while minimizing temperature fluctuations.

The Bryant 345MAV incorporates advanced refrigerant technologies designed for optimal performance. It uses R-410A refrigerant, which is known for its lower environmental impact compared to traditional refrigerants like R-22. This environmentally friendly aspect aligns with regulations aimed at reducing ozone depletion, thereby promoting a greener approach to heating and cooling.

Reliability is another hallmark of the Bryant 345MAV. Engineered with precision, this model features a durable build designed to withstand varying weather conditions. The system is equipped with a robust compressor that is engineered for longevity and minimal noise during operation. Homeowners will appreciate the quiet performance of the 345MAV, ensuring peace in their living spaces.

Comfort also extends to the user experience with the inclusion of a smart thermostat option. This integration allows homeowners to manage their heating and cooling systems remotely, enhancing convenience and control. Programmable settings can optimize energy use based on individual schedules, facilitating both comfort and savings.

In summary, the Bryant 345MAV is a top-tier solution for residential climate control, blending energy efficiency, innovative technology, and unmatched reliability. With its variable-speed operation, environmentally friendly refrigerant, and smart features, the 345MAV represents a significant advancement in the HVAC field. Homeowners investing in this model can expect a system that not only meets their heating and cooling needs but exceeds them in terms of efficiency and comfort.