1.Turn off gas and electrical supplies to the furnace and remove

the main furnace door. (See Fig. 7, 8, and 9.)

2.Remove burner enclosure front. (See Fig. 29 or 30.)

Inspect the gas burners and ignitor area for dirt, rust, soot, or scale.

!CAUTION

If dirt, rust, soot, or scale accu- mulations are found, call your dealer. Do not operate your furnace.

29

30

3.Inspect the combustion-air and vent pipes for sags, holes, cracks, or disconnections.

!DANGER

If holes are found in the pipes or if any portion has become disconnected, toxic fumes can escape into your home.

DO NOT OPERATE YOUR FURNACE. Call your dealer for service.

4.Reinstall burner enclosure front.

5.If your furnace is free of the above conditions, replace main furnace door and turn on electrical and gas supplies to your furnace.

(See Fig. 14, 15, and 16.)

6.Start the furnace and observe its operation. Watch the burner flames to see if they are clear blue, almost transparent. (See Fig. 31.) If you

observe a suspected malfunction, or the burner flames are not clear blue, call your dealer.

31

HEADING SOUTH FOR THE WINTER?

DON’T FORGET YOUR

FURNACE!

!CAUTION

If the furnace is installed in an unconditioned space where the ambient temperatures may be 32°F or lower, freeze protec- tion measures must be taken.

Since the furnace uses a condensing heat exchanger, some water will accu- mulate in the unit as a result of the heat transfer process. Therefore, once it has been operated, it cannot be turned off and left off for an extended period of time when temperatures will reach 32° F or lower unless winterized. Fol- low these procedures to winterize your furnace:

1.Obtain propylene glycol (RV/ swimming pool antifreeze or equivalent).

!CAUTION

Do not use ethylene glycol (Prestone II antifreeze coolant or equivalent). Failure of plas- tic components will occur.

2.Turn off electrical supply to the furnace. (See Fig. 18.)

3.Remove main furnace door. (See Fig. 21.)

4.Remove upper right inducer hous- ing drain connection cap.

(See Fig. 32.)

5.Connect field-supplied 1/2-in.

ID tube to upper inducer housing drain connection.

8

6. Insert field-supplied funnel into tube.

32

33

7.Pour 1 quart of antifreeze into funnel/tube. Antifreeze should run through inducer housing, overfill condensate trap, and flow into open field drain. (See Fig. 33.)

8.Remove funnel and tube from inducer housing and replace drain connection cap and clamp.

9.Replace main furnace door. (See Fig. 28.)

Image 8
Contents Model 345MAV Condensing GAS Furnace Welcome to a NEW Generation of Comfort Model 345MAV FurnaceFurnace Components Model 345MAV Furnace Shown in Upflow PositionStarting Your Furnace Safety ConsiderationsImportant Facts Steps for Starting Your Furnace Filtering OUT Trouble Performing Routine MaintenanceShutting Down Your Furnace AIR Filters Located in Bottom AIR Filter Located in SideReinstall burner enclosure front DON’T Forget Your FurnaceCHECK-UP Checklist Before YOU Request a Service CallFor Insufficient Airflow If Furnace Fails to OperateModel 345MAV Diagnostic Chart See Fig
Related manuals
Manual 40 pages 58.13 Kb Manual 12 pages 34 Kb

345MAV specifications

The Bryant 345MAV is a premier choice in the realm of residential heating and cooling systems, encapsulating advanced technologies, high efficiency, and remarkable performance. Designed for homeowners seeking reliability and comfort, this model exemplifies modern HVAC (Heating, Ventilation, and Air Conditioning) innovations.

One standout feature of the Bryant 345MAV is its impressive energy efficiency. With a high SEER (Seasonal Energy Efficiency Ratio) rating, it operates at peak levels while consuming less energy. This not only reduces utility bills but also supports environmental sustainability, making it an ideal selection for eco-conscious consumers. The model employs variable-speed technology, which allows the system to adjust its output based on current heating and cooling needs. As a result, it provides consistent indoor comfort while minimizing temperature fluctuations.

The Bryant 345MAV incorporates advanced refrigerant technologies designed for optimal performance. It uses R-410A refrigerant, which is known for its lower environmental impact compared to traditional refrigerants like R-22. This environmentally friendly aspect aligns with regulations aimed at reducing ozone depletion, thereby promoting a greener approach to heating and cooling.

Reliability is another hallmark of the Bryant 345MAV. Engineered with precision, this model features a durable build designed to withstand varying weather conditions. The system is equipped with a robust compressor that is engineered for longevity and minimal noise during operation. Homeowners will appreciate the quiet performance of the 345MAV, ensuring peace in their living spaces.

Comfort also extends to the user experience with the inclusion of a smart thermostat option. This integration allows homeowners to manage their heating and cooling systems remotely, enhancing convenience and control. Programmable settings can optimize energy use based on individual schedules, facilitating both comfort and savings.

In summary, the Bryant 345MAV is a top-tier solution for residential climate control, blending energy efficiency, innovative technology, and unmatched reliability. With its variable-speed operation, environmentally friendly refrigerant, and smart features, the 345MAV represents a significant advancement in the HVAC field. Homeowners investing in this model can expect a system that not only meets their heating and cooling needs but exceeds them in terms of efficiency and comfort.