Empire Products FAW-55IP installation instructions Introduction

Page 3

INTRODUCTION

Introduction

Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of a vented wall furnace.

Instructions to Installer

1.Installer must leave instruction manual with owner after installation.

2.Installer must have owner fill out and mail warranty card supplied with furnace.

3.Installer should show owner how to start and operate furnace and thermostat.

Warning:

Any change to this furnace or its control can be dangerous. This is a heating appliance and any panel, door or guard removed for servicing an appliance must be replaced prior to operating the appliance.

General Information

This series is design certified in accordance withAmerican National Standard / CSA Standard Z21.86 and CSA 2.32 by the Canadian Standards Association, as a Fan Type Vented Wall Furnace and must be installed according to these instructions.

Any alteration of the original design, installed other than as shown in these instructions oruse with a type of gas not shown on the rating plate is the responsibility of the person and company making the change.

Important

All correspondence should refer to complete Model No., Serial No. and type of gas.

Notice: During initial firing of this unit, its paint will bake out and smoke will occur. To prevent triggering of smoke alarms, ventilate the room in which the unit is installed.

Installation on Rugs and Tile

If this appliance is installed directly on carpeting, tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance.

The base referred to above does not mean the fire-proof base as used on wood stoves. The protection is for rugs that are extremely thick and light colored tile.

Installation in Residential Garages

Gas utilization equipment in residential garages shall be installed so that all burners and burner ignition devices are located not less than 18” (457mm) above the floor.

Such equipment shall be located, or protected, so it is not subject to physical damage by a moving vehicle.

Specifications

Model

FAW-55IP

BTU/HR (KW/H)

55,000 (16.1)

Height

82 3/8” (2092mm)

Width

16” (406mm)

Depth

11 1/2” (292mm)

Gas Inlet

1/2” (13mm) Pipe

Vent Collar

4” (102mm) Type B Oval

CFM

400

Accessories

See Page 16

THIS IS A HEATING APPLIANCE

DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANELS INSTALLED.

• Due to high temperatures the appliance should be located

circulating air passageways of the appliance be kept

out of traffic and away from furniture and draperies.

clean.

• Children and adults should be alerted to the hazards of

• DO NOT put anything around the furnace that will

high surface temperatures and should stay away to avoid

obstruct the flow of combustion and ventilation air.

burns or clothing ignition.

• DOkeeptheapplianceareaclearandfreefromcombustible

• Young children should be carefully supervised when they

material, gasoline and other flammable vapors and

are in the same room as the appliance.

liquids.

• Clothing orotherflammable material should not be placed

• DO examine venting system periodically and replace

on or near the appliance.

damaged parts.

• Any safety screen or guard removed for servicing an

• DO make a periodic visual check of pilot and burners.

appliance must be replaced prior to operating the

Clean and replace damaged parts.

appliance.

• CAUTION: Pilot hole cover must be kept tightly closed

• Keep burner and control compartment clean.

during operation.

• Installation and repair should be done by a QUALIFIED

• DO NOT use this heater if any part has been under water.

SERVICE PERSON. The appliance should be inspected

Immediately call a qualified service technician to inspect

before use and at least annually by a qualified service

the heater and to replace any part of the control system

person. More frequent cleaning may be required due to

and any gas control which has been under water.

excessive lint from carpeting, bedding materials, etc. It

• This furnace must not be connected to a chimney flue

is imperative that control compartments, burners and

serving a separate solid-fuel burning appliance.

 

12429-10-0408

Page 3

Image 3
Contents Installation Instructions Table of Contents Introduction LP-GAS Warning Odor Safety Information for Users of LP-GASVentilation and Combustion Air InstallationQualified Installing Agency Before Installing Consider The Following VentingInstalling Optional Rear Outlet Pressure Testing of the Gas Supply System Installation of Three-prong Grounding Plug AssemblyInstalling a New Main Gas Cock Method of Installing a Tee Fitting Sediment TrapProper Pilot Flame Safety LockoutChecking Manifold Pressure High AltitudesInsulated Vent Enclosure WiringThermostat Installation Vent Safety Shutoff SystemLighting Instructions For Your Safety Read Before OperatingPilot Ignition Service and Maintenance SuggestionsMain Burner Operation S8600H Normal Operating SequenceIgnition System Checks Check ignition cable. Make sure TroubleshootingS8600H Troubleshooting Guide Green LED Status Codes How To Order Repair Parts Parts ListParts View 102mm Oval In-The-Wall all parts purchase locally AccessoriesVenting 102mm Round all parts purchase locally except itemService Notes Comfort Systems

FAW-55IP specifications

The Empire Products FAW-55IP represents a significant advancement in the realm of portable air conditioning systems. This model blends efficiency, portability, and modern technology to provide an unparalleled cooling experience. Designed for both residential and commercial use, the FAW-55IP is ideal for spaces that require reliable climate control without the need for permanent installation.

One of the standout features of the FAW-55IP is its impressive cooling capacity. With a powerful 55,000 BTU rating, it can effectively cool large areas, making it perfect for workshops, retail spaces, and larger rooms in homes. The unit is equipped with a high-efficiency compressor that not only cools effectively but also provides energy savings, making it an eco-friendly choice.

The FAW-55IP utilizes advanced inverter technology, allowing for variable speed operation. This means that the unit can adjust its cooling output based on the ambient temperature, ensuring a more consistent temperature control while minimizing energy consumption. This feature significantly reduces electricity costs compared to traditional air conditioning units.

Portability is another key aspect of the FAW-55IP. With built-in caster wheels and a lightweight design, this air conditioning unit can be easily moved from one room to another, allowing for versatility in its use. Whether you need to cool down a living space during hot summer months or provide comfort in a temporary workspace, this model meets a variety of cooling needs.

The user-friendly digital control panel makes operation simple, with options for adjusting the temperature, fan speed, and mode settings. Additionally, the unit comes with a remote control, allowing users to make adjustments from a distance. Its programmable timer function adds to the convenience, enabling users to set the unit to operate on a schedule that suits their lifestyle.

Furthermore, the FAW-55IP includes advanced filtration technology that helps enhance indoor air quality. The washable filter captures dust, allergens, and other particles, ensuring that the cooled air is clean and fresh. This is particularly beneficial for those with allergies or respiratory conditions, as it helps to create a healthier indoor environment.

In summary, the Empire Products FAW-55IP stands out due to its robust cooling capacity, efficient inverter technology, portability, user-friendly controls, and advanced filtration system. As such, it represents an excellent investment for anyone looking to improve their indoor climate comfort while keeping energy consumption in check.