Product Features and Specifications

36J Series

Replacement Electronic Ignition Gas Valve. The versatile 36J series combination gas valves cover a wide range of applica- tions. Designed for use with common ignition systems (HSI/DSI), it replaces hundreds of existing models in the field.

Features

 

• HSI/DSI

• Inlet/outlet screens

• Single Stage/Two-Stage

• Electric on-off switch

• Fast/Slow Opening

• Inlet/outlet pressure taps

• Convertible – natural or LP Gas

• CSA approved

• Adjustable regulator(s)

 

Specifications

 

Electrical Rating

0.28 amps (Single Stage)

 

0.43 amps (Two-Stage)

Voltage

24 VAC

Frequency

50/60 Hz

Operating Ambient Temperature

-40° to 175°F (-40°to 79°C)

Pressure Rating (max.)

1/2 PSI (14.0" W.C.)

 

2.750

SWITCH

 

SWING

 

RADIUS

(SHIPPED IN "ON" POSITION)

 

 

0.500

4.243

1.250

 

 

 

1.329

 

 

INLET - 1/2" N.P.T.

 

 

(PLASTIC DUST PLUG INSTALLED)

 

ALL DIMENSIONS

4.693

IN INCHES

 

 

1" PD Capacity

Pipe Size

BTU/HR

NAT GAS

LP GAS

(36 J)

Pipe Size

0.64 Sp. Gr.

1.53 Sp. Gr.

(36 J)

(1000 BTU/HR)

(2500 BTU/HR)

1/2" x 1/2"

140,000

226,800

1/2" x 1/2"

1/2" x 1/2"

140,000

226,800

1/2" x 1/2"

 

 

 

 

Regulator

Valve

Adjustment

Stages

Range

Valve

 

 

Stages

Nat. Gas

LP Gas

Single

2.5" to 5.0"

7.0" to 12.0"

Stage

 

 

Two-

1.0" – 4.0" Low

4.0" – 10.0" Low

Stage

2.0" – 5.0" High

6.0" – 12.0" High

 

 

 

 

 

 

 

 

 

 

LP

 

Reducer

 

Inlet

Outlet

Model

 

Type of

Pipe

Opening

Regulator

Convertible

Conversion

Flow

Bushing

Filter

Pressure

Pressure

Number

Voltage

Gas

Size

Characteristics

Setting

Nat./LP

Kit Included

Direction

Kit

Screen

Tap

Taps

36J22-214

24 VAC

Nat./LP

1/2 x 1/2

Fast

3.5"

Yes

Yes

Str. Thru

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

36J24-214

24 VAC

Nat./LP

1/2 x 1/2

Slow

3.5"

Yes

Yes

Str. Thru

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

36J54-214

24 VAC

Nat./LP

1/2 x 1/2

2-Stage – Fast

LO 1.5" – HI 3.5"

Yes

Yes

Str. Thru

Yes

Yes

Yes

Yes

36J55-214

24 VAC

Nat./LP

1/2 x 1/2

2-Stage – Slow

LO 1.5" – HI 3.5"

Yes

Yes

Str. Thru

Yes

Yes

Yes

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

36J24-614

24 VAC

Nat./LP

1/2 x 1/2

Slow

3.5"

Yes

Yes

90° Bottom Outlet

No

Yes

Yes

Yes

36J55-614

24 VAC

Nat./LP

1/2 x 1/2

2-Stage – Slow

LO 1.5" – HI 3.5"

Yes

Yes

90° Bottom Outlet

No

Yes

Yes

Yes

Gas Valve Cross Reference 13

Image 13
Contents Gas Valve Cross Reference Online Cross Reference IndexHot Surface Ignition Gas Valve Selection GuideStanding Pilot Range of Operation 36C XX X 36C Nomenclature36J Nomenclature 36H Nomenclature36H XX X Hot Surface Ignition HSI System ApplicationsDirect Spark Ignition DSI Proven Pilot Standing PilotCycle Pilot Harnesses Cycle Pilot System36C Series Product Features and SpecificationsNAT GAS LP GAS 36H SeriesHSI/DSI 36J SeriesAccessories Product Accessories0002-42-174 Cross Reference13005223 26A01-12 Cross Reference Cross Reference Cross Reference Cross Reference Cross Reference 4788337 5H3207B1 SLS520DE Cross Reference Cross Reference VS8233B2X4 36C03U-433