STEPS FOR STARTING YOUR FURNACE

1.Open all warm air registers and make sure that all return-air grills are unobstructed.

2.If a humidifier is installed with your system, open the water supply valve.

3.Make sure blower access door is secured in place.

4.Set your room thermostat to the lowest temperature setting. (See Fig. 5.)

®

5

5.Turn on electric power to the furnace. (See Fig. 6.)

6.Open the oil supply valve. (See Fig. 7.)

5

67

7.Check all connections to ensure there are no leaks.

8.Set room thermostat to a temperature slightly above room temperature. This will automatically signal the furnace to start.

9.When the thermostat calls for heat, power from the transformer energizes the fan control board. The fan control energizes the ignition control. The ignition control will automatically light the burner.

The electronic fan control automatically turns on the blower. The air moved over the heat exchanger by the blower is warmed and passes through the ducts to the room registers.

This unit is equipped with a continuous ignition control. If the main burner does not ignite within 30 sec from the call for heat, the control will lock out. The red button on top of the control must be depressed for 3 sec in order to reset the control.

The control CANNOT be reset from the room thermostat.

10.Set your thermostat to the temperature that satisfies your comfort requirements. SUGGESTION: Set- ting the thermostat back a few degrees and compen- sating for the difference with warmer clothing can make a big difference in your fuel consumption on extremely cold days. The few degrees at the top of your thermostat “comfort level” are the most costly degrees to obtain.

When room temperature drops below the tempera- ture selected on the thermostat, the furnace will be switched on automatically. When room temperature reaches the degree selected on the thermostat, the furnace will be switched off automatically.

Some thermostats have a FAN mode with 2 selec- tions, AUTO and ON. When thermostat is set to AUTO, the furnace blower cycles on and off, con- trolled by the thermostat. In ON mode, the furnace blower runs continuously. This keeps the tempera- ture level in your home more evenly balanced. It also continuously filters the indoor air.

Image 5
Contents 58VLR OIL FurnaceAccessories Installation DataWelcome to a NEW Generation of Comfort FurnaceFurnace Components For Your Safety Safety ConsiderationsImportant Facts Starting Your FurnaceElectrical Shock Hazard High VOLT- AGE AT Igniter Steps for Starting Your FurnaceFiltering OUT Trouble Performing Routine MaintenanceShutting Down Your Furnace Furnace AIR Filter Table CHECK-UP ChecklistFor Insufficient Airflow Before YOU Request Service Call