Superior CFPF-CMP, CFST-CMP, CFPF-CMN, CFST-CMN installation instructions Standard

Page 8

Step 2. Route a ¹⁄₂" (13 mm) gas line along the left or right side framing (Figure 9 ).

All appliances have a 3" long ³⁄₈" NPT nipple installed at the valve. To quickly and easily complete the gas line routing, use the gas flex line kit, Model GFLV.

¹⁄₂” Gas

Stud

Plate

Line

 

 

3 ⁷⁄₈"

 

(98 mm)

 

4"

Standard

(102 mm)

Left Side

 

Gas Flex Line Kit, Model GFLV

³ " NPT x ³ "

¹ " x ³ " FlareFlare Fitting Shut-Off Valve

³ " Flex Tubing

³ " Union

Gas Stub

³ " Close Nipple

³ " Shut-Off Valve

¹ " x ³ " Reducer

To Appliance

Gas Valve

Stud

¹⁄₂” Gas

Plate

Line

 

11³⁄₈"

 

(289 mm)

 

 

Optional

 

 

 

4

¹⁄₈"

Right Side (ST)

(105 mm)

 

Figure 9

Step 3. Remove the nailing flanges from the lower control compartment and install in place with three (3) screws each. Align with the three holes on each side of the appliance (refer to Figure 5 ).

Install the hood on all units. Position the hood in the open area above the appliance door. Insert the tabs, on each end of the hood, into the bracket at each end. Bend the two tabs over to secure.

Step 4. Position appliance into prepared fram- ing, secure with 6d nails at the nailing flange along each side.

Step 5. Connecting Gas Line – Make gas line connections. All codes require a shut-off valve mounted in the supply line. Figure 10 illus- trates two methods for connecting the gas supply. Installation methods and materials must be in compliance with local codes.

Figure 10

Control

Valve

Lower Control

Compartment Door

Figure 11

The gas control valve is located in the lower control compartment. To access the valve open the lower control compartment door (Figure 11 ).

The control valve has a ³⁄₈" NPT thread inlet port and is fitted with two elbows and a nipple to provide the necessary offset. Plan your connections accordingly.

Secure all joints tightly using appropriate tools and sealing compounds (ensure propane resis- tant compounds are used in propane applica- tions). Turn on gas supply and test for gas leaks using a soapy water solution. Never use an open flame to check for leaks.

A. Mix a 50% dish soap, 50% water solution.

B. Light the appliance (refer to safety and lighting instructions on page 15).

C. Brush all joints and connections with the soapy water solution to check for leaks. If bubbles are formed, or gas odor is detected, turn the gas control knob to the “OFF” position. Either tighten or refasten the leaking connec- tion and retest as described above.

D. When the gas lines are tested and leak free, observe the individual tongues of flame on the burner. Make sure all ports are open and pro- ducing flame evenly across the burner. If any ports are blocked, or partially blocked, clean out the ports.

An external regulator must be used on all pro- pane (L.P.G.) heaters, in addition to the regula- tor fitted to the heater, to reduce the supply tank pressure to 13" w.c. (maximum).

WARNING: CONNECTING DIRECTLY TO AN UNREGULATED PROPANE TANK CAN CAUSE AN EXPLOSION.

Step 6. Wiring – The wiring diagram is de- tailed in Figure 12. Refer to Figure 13 to field wire optional wall switch. All electrical wiring must be in accordance with local codes or, in the absence of local codes the latest edition of the National Electrical Code, ANSI/NFPA 70. The heater must be electrically grounded.

8

NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.

Image 8
Contents Retain These Instructions For Future Reference Unvented Decorative Gas Fireplaces 903589 REV. E 02/2004Table of Contents Combustion and Ventilation AIR Do not install these heaters in a bedroom or bathroomCodes Location of Fireplace ClearancesHigh Traffic Areas Windy or Drafty Areas ExamplePreinstallation Assembly StepsInstallation Steps Check Gas TypeCfst Framing Specifications Framing Dimensions22 ³⁄₄ 578 mm* B 43 1092 mm Min. C 43 1092 mm Min Drywall finishCfpf Framing Specifications ³⁄₄ 578 mm¹⁄₈ 1016 mm Min 43 1092 mm MinStandard Finished Wall Details Standard Wiring DiagramOptional Wiring Diagram Position the rockwool over the burner screen as shown in B Assembling the LogsFlames should not impinge on the logs Replace logs if removed for pilot inspection Flame AppearanceAppliance Operation Optional Equipment Cleaning and Servicing Replacement PartsDecorative Arch Kits Gas Flex Line with ValveAccessories and Components SPK-6Operating Instructions What to do if YOU Smell GASLighting Instructions To Turn OFF GAS to HeaterPilot Assembly Pilot Location Turn Control Knob to OFF PositionTurn Control Knob to Pilot Position Turn Control Knob to on PositionCfst Replacement Parts List Cfst GAS Controls MillivoltCFST-CMN DescriptionReplacement Parts Cfst CFPF-CMN Cfpf Replacement Parts ListCfpf GAS Controls Millivolt Replacement Parts Cfpf Observed Problem Possible Cause RemedyPage Page 903589 REV. E 02/2004 Orange, CA