Step 7. Installing the Optional Remote Wall | CAUTION: DO NOT CONNECT THE OPTIONAL |
Switch – The standard millivolt system comes | REMOTE SWITCH TO A 120V POWER SUPPLY. |
from the factory wired as shown in Figure 12. | Note: The optional rocker switch is mounted to |
Select a convenient location for the remote wall | |
switch and connect the wiring to the appliance | the appliance and wired in the same way as the |
(Figure 13 ). | remote wall switch. |
Standard Wiring Diagram
If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105° C – 18 GA. wire.
| * | |
THERMOCOUPLE |
| |
| THERMOPILE | |
| BLK | |
GAS CONTROL VALVE | BLK | |
WHT | ||
| ||
TH |
| |
TP |
| |
TH & TP | RED |
RED
DOOR SW
*For Optional Wall and/or On/Off Switch Attachment
Figure 12
Optional Wiring Diagram
If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105° C – 18 GA. wire.
|
| OPTIONAL WALL AND/OR ON/OFF | |
|
| ROCKER SWITCH | |
THERMOCOUPLE |
|
| |
|
| THERMOPILE | |
|
| BLK | |
GAS CONTROL VALVE | BLK | ||
WHT | |||
|
| ||
| TH |
| |
| TP |
| |
| TH & TP | RED | |
| RED |
| |
|
| DOOR SW | |
Factory Wired | Field Wired |
|
Figure 13
Note: Supply wires may be alternatively connected to the outlet using the screw terminals, however the black supply wire must be ganged wired to the same terminal that the
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.
Step 8. Installing the Optional Forced Air Blower Kit Wiring – An electrical outlet box is provided for the installation of the
Route a
IMPORTANT: Ground lead must be con- nected to the green screw on the recep- tacle. Failure to do so will prevent the appliance from operating. The appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, the National Electrical Code, ANSI/ NFPA 70- latest edition. (In Canada, the cur- rent CSA
The forced air blower kit may be mounted at initial appliance installation or at any time thereafter. Follow the instructions provided with the blower kit.
Finished Wall Details
It is sometimes best to frame the appliance after it has been positioned in place. Frame with 2 x 4s or heavier lumber. Always frame in accordance with local building codes.
Note: The header may rest on the top spacers but must not be notched to fit around them.
In order to install the appliance facing flush with the finished wall, position the framework to accommodate the thickness of the finished wall (Refer to Figures 2, 4, 5, 7 and 8 ).
If you live in a cold climate, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests, if floor is above ground level.
9