Superior CFST-CMP Standard Wiring Diagram, Optional Wiring Diagram, Finished Wall Details

Page 9

Step 7. Installing the Optional Remote Wall

CAUTION: DO NOT CONNECT THE OPTIONAL

Switch – The standard millivolt system comes

REMOTE SWITCH TO A 120V POWER SUPPLY.

from the factory wired as shown in Figure 12.

Note: The optional rocker switch is mounted to

Select a convenient location for the remote wall

switch and connect the wiring to the appliance

the appliance and wired in the same way as the

(Figure 13 ).

remote wall switch.

Standard Wiring Diagram

If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105° C – 18 GA. wire.

 

*

THERMOCOUPLE

 

 

THERMOPILE

 

BLK

GAS CONTROL VALVE

BLK

WHT

 

TH

 

TP

 

TH & TP

RED

RED

DOOR SW

*For Optional Wall and/or On/Off Switch Attachment

Figure 12

Optional Wiring Diagram

If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105° C – 18 GA. wire.

 

 

OPTIONAL WALL AND/OR ON/OFF

 

 

ROCKER SWITCH

THERMOCOUPLE

 

 

 

 

THERMOPILE

 

 

BLK

GAS CONTROL VALVE

BLK

WHT

 

 

 

TH

 

 

TP

 

 

TH & TP

RED

 

RED

 

 

 

DOOR SW

Factory Wired

Field Wired

 

Figure 13

Note: Supply wires may be alternatively connected to the outlet using the screw terminals, however the black supply wire must be ganged wired to the same terminal that the pre-wired black wire is attached to and the white supply wire must be connected to the opposite side of the outlet.

NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.

Step 8. Installing the Optional Forced Air Blower Kit Wiring – An electrical outlet box is provided for the installation of the FAB-1100 forced air blower kit (optional). Electrical power must be provided to this box to operate the blower.

Route a 3-wire, 120Vac power line with con- trol switch to the lower right rear corner of the appliance. Make connections to the receptacle as shown in Figure 14.

IMPORTANT: Ground lead must be con- nected to the green screw on the recep- tacle. Failure to do so will prevent the appliance from operating. The appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, the National Electrical Code, ANSI/ NFPA 70- latest edition. (In Canada, the cur- rent CSA C22-1 Canadian Electrical Code.)

The forced air blower kit may be mounted at initial appliance installation or at any time thereafter. Follow the instructions provided with the blower kit.

Finished Wall Details

It is sometimes best to frame the appliance after it has been positioned in place. Frame with 2 x 4s or heavier lumber. Always frame in accordance with local building codes.

Note: The header may rest on the top spacers but must not be notched to fit around them.

In order to install the appliance facing flush with the finished wall, position the framework to accommodate the thickness of the finished wall (Refer to Figures 2, 4, 5, 7 and 8 ).

If you live in a cold climate, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests, if floor is above ground level.

9

Image 9
Contents Unvented Decorative Gas Fireplaces 903589 REV. E 02/2004 Retain These Instructions For Future ReferenceTable of Contents Do not install these heaters in a bedroom or bathroom CodesCombustion and Ventilation AIR Clearances Location of FireplaceHigh Traffic Areas Windy or Drafty Areas ExampleAssembly Steps PreinstallationInstallation Steps Check Gas TypeFraming Dimensions Cfst Framing Specifications22 ³⁄₄ 578 mm* B 43 1092 mm Min. C 43 1092 mm Min Drywall finish³⁄₄ 578 mm Cfpf Framing Specifications¹⁄₈ 1016 mm Min 43 1092 mm MinStandard Standard Wiring Diagram Optional Wiring DiagramFinished Wall Details Assembling the Logs Flames should not impinge on the logsPosition the rockwool over the burner screen as shown in B Flame Appearance Appliance OperationReplace logs if removed for pilot inspection Optional Equipment Replacement Parts Cleaning and ServicingDecorative Arch Kits Gas Flex Line with ValveSPK-6 Accessories and ComponentsWhat to do if YOU Smell GAS Operating InstructionsLighting Instructions To Turn OFF GAS to HeaterTurn Control Knob to OFF Position Pilot Assembly Pilot LocationTurn Control Knob to Pilot Position Turn Control Knob to on PositionCfst GAS Controls Millivolt Cfst Replacement Parts ListCFST-CMN DescriptionReplacement Parts Cfst Cfpf Replacement Parts List Cfpf GAS Controls MillivoltCFPF-CMN Replacement Parts Cfpf Possible Cause Remedy Observed ProblemPage Page Orange, CA 903589 REV. E 02/2004