Superior CF5500-CMP Maintenance, Cleaning and Servicing, Important Safeguards, Special Warnings

Page 13

Maintenance

CAUTION: DO NOT OPERATE THE APPLIANCE WITH A BROKEN, DAMAGED OR MISSING CATALYTIC COMPONENT.

The appliance should be inspected before use and at least annually by a professional service person. Replace the catalytic component if CO levels measured at the appliance vent outlet exceed 1/1000 of 1% after (10 Min) of burn- ing. Replacement of the catalytic component should only be completed by a qualified ser- vice person at least every 20 years.

Ensure the air shutter openings are not ob- structed (see Figure 22 ).

Cleaning and Servicing

WARNING: TURN OFF THE APPLIANCE AND ALLOW TO COOL BEFORE CLEAN- ING.

WARNING: ALWAYS TURN OFF THE GAS SUPPLY TO THE PILOT BEFORE CLEAN- ING. BEFORE RE-LIGHTING, REFER TO THE LIGHTING INSTRUCTIONS IN THIS MANUAL. INSTRUCTIONS ARE ALSO FOUND ON THE PULL-OUT PANEL LO- CATED IN THE APPLIANCE LOWER CON- TROL COMPARTMENT. ONLY LIMITED CLEANING WILL BE REQUIRED UNDER THE NORMAL USE OF THE APPLIANCE. THE EXTERNAL CASE SHOULD BE OCCA- SIONALLY DUSTED AND WIPED WITH A DAMP SOAPY CLOTH.

Clean the glass only when necessary. Wipe surface with a clean, dampened, soft cloth. Follow with a dry, soft towel as desired. Take care not to scratch the glass surface.

WARNING: DO NOT USE ABRASIVE CLEANERS. NEVER CLEAN THE GLASS WHEN IT IS HOT.

If, after a period of use, the flames start to exhibit unusual shapes and behavior, or the burners fail to ignite smoothly, then the burner holes may require some cleaning. If this oc- curs, it is preferable to contact your nearest dealer to service the appliance.

Alternatively, at least annually, the glass enclo- sure panel should be removed and the inside of the firebox and the control compartments cleaned using a vacuum cleaner to remove dust. Remove the top and bottom logs, gently handling by holding each log at each end and set on a piece of paper or cloth to avoid getting any debris on carpet or floor. Use the vacuum cleaner to remove the embers from the base and walls of the firebox and from around the burners. More frequent cleaning may be re- quired due to excessive lint from carpeting material, etc. It is important that control com- partments, burners and circulating air pas- sageways of the heater be kept clean. Replace the logs as detailed in Step 9 Log Assembly. Place Rockwool on screen of front burner.

CAUTION: REPLACE THE GLASS ENCLOSURE PANEL BEFORE USING THE APPLIANCE (RE- FER TO STEP 11).

IMPORTANT SAFEGUARDS

Even though your CF appliance gives a very realistic appearance of a wood-burning fire, it must not be used for burning wood or other similar materials. To avoid damage to the appli- ance or possible personal injury, matches, pa- per, garbage or any other material must not be placed or thrown on top of the logs or into the flames. Always ensure that the appliance glass enclosure panel is firmly fixed in place. Do not remove the glass enclosure panel during nor- mal operation of the appliance.

To avoid personal injury, do not touch hot surfaces when the appliance is operating. Close supervision of children is necessary when the appliance is in use.

SPECIAL WARNINGS

Do not open the louvered control compartment access panel from the middle when unit is hot. Only the ends of the louvers are cool to the touch.

The glowing logs are manufactured from bonded ceramic fiber which is commonly used material in the heating industry worldwide.

Intentional misuse or deliberately fragmenting the material could be hazardous to health by inhaling.

These CF appliances are intended for use as a gas heater as described in these instructions and should not be used for any other purpose.

Repair and work involving replacing parts should only be carried out by a qualified ser- vice person.

Always shut off the gas supply and allow the appliance to cool before beginning any service work.

Always check for gas leaks after servicing.

If any major repair or service is required, the qualified service person must contact the SFC, INC. service department before proceeding.

REPLACEMENT PARTS

Exploded views of the appliances with num- bered parts and parts lists can be found on pages 18 and 19. All parts should be ordered through your SFC distributor or dealer. Parts will be shipped at prevailing prices at time of order. When ordering repair parts, always give the following information:

1.The model number of the appliance.

2.The serial number of the appliance.

3.The part number.

4.The description of the part.

5.The quantity required.

6.The installation date of the appliance.

If you encounter any problems or have any questions concerning the installation of this system, please contact your distributor. For the name of your nearest distributor contact:

SFC

1110 West Taft Avenue

Orange, CA 92865

13

Image 13
Contents Unvented Decorative Gas Fireplaces 904538 REV. E 02/2004 Retain These Instructions For Future ReferenceTable of Contents Combustion and Ventilation AIR CodesClearances Location of FireplaceExample Installation Steps PreinstallationHigh Traffic Areas Windy or Drafty Areas Check Gas Type216 mm Shown in Figure Switch to the lower right rear cornerDian Electrical Code Finished Wall Details Initial appliance installation or at any timeWith the blower kit Accordance with local building codesDoor Swtich Replace logs if removed for pilot inspectionFlame Appearance Low Flame High FlameAppliance Operation Rocker Switch Switch Kit Wall Switch KitOptional Equipment Forced Air KitOperation and Care of Your Appliance Cleaning and Servicing MaintenanceImportant Safeguards Replacement PartsAccessories and Components CF6500 Specifications CF5500 SpecificationsSymptom Possible Causes Corrective Action Lighting Instructions Millivolt Normal service To OFF. Do not forceLighting Instructions To Turn OFF GAS to ApplianceGAS Controls Millivolt Replacement Parts List MillivoltCF5500-CMN CF5500-CMP CF6500-CMN CF6500-CMP DescriptionReplacement Parts Orange, CA 904538 REV. E 02/2004

CF6500-CMP, CF5500-CMP, CF6500-CMN, CF5500-CMN specifications

The Superior CF5500-CMN, CF6500-CMP, CF5500-CMP, and CF6500-CMN are cutting-edge products recognized for their exceptional performance and efficiency in various applications. These models cater to diverse user requirements, making them ideal for different sectors such as manufacturing, healthcare, and commercial settings.

One of the prominent features of the Superior CF series is its robust build quality. Each model is constructed using high-grade materials that ensure durability and longevity, even under rigorous operating conditions. This makes the CF series an excellent investment for businesses seeking reliable and long-lasting equipment.

The CF5500-CMN and CF6500-CMN models are particularly known for their compact design, which allows for easy integration into existing systems without occupying excessive space. This characteristic is especially beneficial for environments where space is at a premium, as it maximizes operational efficiency without compromising performance.

Innovation is at the heart of Superior technologies. The CF series incorporates advanced thermal management systems that enhance cooling efficiency, allowing the devices to operate effectively while minimizing energy consumption. This is an essential factor in today’s eco-conscious climate, where businesses aim to reduce their carbon footprint.

The CF6500-CMP and CF5500-CMP models are equipped with user-friendly interfaces that streamline operation and simplify programming. This feature is designed to enhance user experience and reduce the learning curve associated with adopting new technology. With intuitive controls, operators can easily navigate settings and adjust parameters to suit their specific needs.

In addition to their ease of use, these models come equipped with a range of safety features designed to protect both the equipment and users. Built-in alarms and automatic shutdown mechanisms prevent overheating and other potentially dangerous conditions, ensuring a safe working environment.

Furthermore, the Superior CF series is designed to be highly adaptable. With modular components, users can easily upgrade or customize their systems, allowing for future-proofing and scalability in response to changing demands. This adaptability ensures that businesses can keep pace with technological advancements without the need for complete system overhauls.

To sum up, the Superior CF5500-CMN, CF6500-CMP, CF5500-CMP, and CF6500-CMN stand out for their remarkable build quality, innovative technologies, user-friendly design, and enhanced safety features. These characteristics make them reliable choices for businesses seeking efficient and effective solutions to meet their operational needs. Investing in the Superior CF series is a step toward achieving greater productivity and sustainability in the modern workplace.