Superior CF5500-CMN, CF6500-CMP, CF5500-CMP, CF6500-CMN installation instructions 216 mm

Page 6

Note: Framing dimensions in Figures 4 - 9 are calculated for a nailing flange depth of ¹⁄₂" (13 mm).

 

Back Wall of

 

Back Wall of

 

Chase/Enclosure

 

Chase/Enclosure

Outside Wall

Including Finishing

Outside Wall

Including Finishing

Materials If Any.

Materials If Any.

 

 

 

15¹⁄₂"

(394mm)

37" (940mm)

CF5500

Figure 4

Back Wall of

Chase/Enclosure

Including Finishing

Materials If Any.

41"

(1041mm)

13 ¹ "

(343mm)

29"

(737mm)

37" (940mm)

58 ¹ " (1473mm)

CF5500

Figure 5

19 ¹⁄₂"

(495mm)

41" (1041mm)

CF6500

Figure 7

 

Back Wall of

 

Chase/Enclosure

 

Including Finishing

 

Materials If Any.

47 ⁷ "

 

(1216mm)

14 ¹ "

 

 

(362mm)

33 ⁷ "

(860mm)

41" (1041mm)

67 ³ " (1721mm)

CF6500

Figure 8

 

 

CF6500 - 8¹⁄₂"

 

 

 

 

(216 mm)

 

 

3"

CF5500 - 7¹⁄₂"

(191 mm)

(76 mm)

 

Figure 10

Step 3. Remove the nailing flanges from the lower control compartment and install in place with three (3) screws each. Align with the three holes on each side of the appliance (see Figure 11 ).

Nailing Flange

37 ¹⁄₄"

 

42 ³⁄₈"

(946 mm)

 

(1076 mm)

 

 

15

¹⁄₂"

19 ¹⁄₂"

(495 mm)

(394 mm)

41"

37"

 

 

(1041 mm)

(940 mm)

 

 

 

Figure 11

All units come complete from the factory with an installed hood. Ensure that the hood is installed. If required, position the hood in the open area above the appliance door covering the diverter baffles. Insert the tabs, on each end of the hood, into the bracket at each end. Bend the two tabs over to secure.

Step 4. Position appliance into prepared fram- ing, secure with 6d nails at the nailing flange along each side.

6

CF5500

Figure 6

The header may be in direct contact with the top metal spacers, but must not rest on them or be notched to fit around them.

Step 2. Route a ¹⁄₂" (13 mm) gas line along the left or right side framing (see Figure 10 ).

CF6500

Figure 9

All appliances have a 3" long ³⁄₈" NPT nipple installed at the valve. To quickly and easily complete the gas line routing, use the gas flex line kit, Model GFLV.

NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.

Step 5. Connecting Gas Line – Make gas line connections. All codes require a shut-off valve mounted in the supply line. Figure 12 illus- trates two methods for connecting the gas supply. Installation methods and materials must be in compliance with local codes.

Image 6
Contents Retain These Instructions For Future Reference Unvented Decorative Gas Fireplaces 904538 REV. E 02/2004Table of Contents Codes Combustion and Ventilation AIRLocation of Fireplace ClearancesExample High Traffic Areas Windy or Drafty Areas PreinstallationInstallation Steps Check Gas Type216 mm Switch to the lower right rear corner Shown in FigureDian Electrical Code With the blower kit Initial appliance installation or at any timeFinished Wall Details Accordance with local building codesReplace logs if removed for pilot inspection Door SwtichLow Flame High Flame Flame AppearanceAppliance Operation Optional Equipment Wall Switch KitRocker Switch Switch Kit Forced Air KitOperation and Care of Your Appliance Important Safeguards MaintenanceCleaning and Servicing Replacement PartsAccessories and Components CF5500 Specifications CF6500 SpecificationsSymptom Possible Causes Corrective Action Lighting Instructions Normal service To OFF. Do not forceLighting Instructions Millivolt To Turn OFF GAS to ApplianceCF5500-CMN CF5500-CMP CF6500-CMN CF6500-CMP Replacement Parts List MillivoltGAS Controls Millivolt DescriptionReplacement Parts 904538 REV. E 02/2004 Orange, CA

CF6500-CMP, CF5500-CMP, CF6500-CMN, CF5500-CMN specifications

The Superior CF5500-CMN, CF6500-CMP, CF5500-CMP, and CF6500-CMN are cutting-edge products recognized for their exceptional performance and efficiency in various applications. These models cater to diverse user requirements, making them ideal for different sectors such as manufacturing, healthcare, and commercial settings.

One of the prominent features of the Superior CF series is its robust build quality. Each model is constructed using high-grade materials that ensure durability and longevity, even under rigorous operating conditions. This makes the CF series an excellent investment for businesses seeking reliable and long-lasting equipment.

The CF5500-CMN and CF6500-CMN models are particularly known for their compact design, which allows for easy integration into existing systems without occupying excessive space. This characteristic is especially beneficial for environments where space is at a premium, as it maximizes operational efficiency without compromising performance.

Innovation is at the heart of Superior technologies. The CF series incorporates advanced thermal management systems that enhance cooling efficiency, allowing the devices to operate effectively while minimizing energy consumption. This is an essential factor in today’s eco-conscious climate, where businesses aim to reduce their carbon footprint.

The CF6500-CMP and CF5500-CMP models are equipped with user-friendly interfaces that streamline operation and simplify programming. This feature is designed to enhance user experience and reduce the learning curve associated with adopting new technology. With intuitive controls, operators can easily navigate settings and adjust parameters to suit their specific needs.

In addition to their ease of use, these models come equipped with a range of safety features designed to protect both the equipment and users. Built-in alarms and automatic shutdown mechanisms prevent overheating and other potentially dangerous conditions, ensuring a safe working environment.

Furthermore, the Superior CF series is designed to be highly adaptable. With modular components, users can easily upgrade or customize their systems, allowing for future-proofing and scalability in response to changing demands. This adaptability ensures that businesses can keep pace with technological advancements without the need for complete system overhauls.

To sum up, the Superior CF5500-CMN, CF6500-CMP, CF5500-CMP, and CF6500-CMN stand out for their remarkable build quality, innovative technologies, user-friendly design, and enhanced safety features. These characteristics make them reliable choices for businesses seeking efficient and effective solutions to meet their operational needs. Investing in the Superior CF series is a step toward achieving greater productivity and sustainability in the modern workplace.