Superior GHC/GRD-5500 installation instructions Table of Contents

Page 2

2

TABLE OF CONTENTS

 

 

Packaging

page

2

Introduction

page

2

General Information

page

2

Location

page

3

Appliance Specifications - 5500

page

4

Appliance Specifications - 6500

page

5

Venting

page

6

Clearances

page

6

Framing Specifications

page

6

Typical Installation Sequence

page

7

Pre-Installation Notes

page

7

Installation

page

8

Field Wiring

page

9

Connecting Gas Line

page

11

Outside Air Kit Installation

page

11

Log and Rockwool Installation

page

12

Appliance Operation

page

12

Millivolt Appliance Checkout

page

12

Electronic Appliance Checkout

page

13

Safety Limit Switch Operation

page

13

Adjustments

page

14

Finishing Requirements

page

14

Cold Climate Insulation

page

16

Installation Accessories

page

16

Gas Conversion Kits

page 16

This installation manual will help you obtain a safe, efficient, dependable installation for your appliance and vent system.Please read and understand these instructions before begin- ning your installation.

PACKAGING

The assembled vented gas fireplace is pack- aged with:

1- one cartoned log set located in firebox area.

2- one bag of glowing embers (rockwool) located in the bottom compartment.

3- one envelope containing the literature package which consists of the homeowner's manual, installation instructions, and war- ranty; envelope is located in the control area.

4- wall switch for burner operation taped to top of unit.

INTRODUCTION

The GHC-5500/6500N, P models are circulat- ing system appliances; the GRD-5500/6500N, P models are radiant heat system appliances; both types utilize a millivolt gas control valve and a piezo ignition system. There is no need for an external power source to operate these systems. They are designed to operate on either natural or propane gas.

The GHC-5500NE-2, PE-2 and GHC-6500EN, EP models are circulating system appliances; the GRD-5500NE-2, PE-2 and GRD-6500EN, EP models are radiant heat system appliances; both utilize an electronic gas control valve along with an intermittent ignition system.

These systems require an external power source in order to operate. They are designed to oper- ate on either natural or propane gas.

These appliances comply with National Safety Standards and are tested and listed by Warnock Hersey (Report No. J20046562 - for 5500 series; J20046564 - for 6500 series models) to ANSI Z21.50 - 2000 (in Canada, CSA 2.22 - 2000), and CAN/CGA-2.17-M91 in both USA and Canada, as vented gas fireplaces.

Installation must conform to local codes. In the absence of local codes, installation must comply with the current National Fuel Gas Code, ANSI Z223.1 (NFPA 54). (In Canada, the current CAN/CGA B149 installation code.) Elec- trical wiring must comply with local codes. In the absence of local codes, installation must be in accordance with the National Electrical Code, NFPA 70 - (latest edition). (In Canada, the current CSA C22.1 Canadian Electric Code.)

DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THE APPLIANCE OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION MAY VOID THE WARRANTY, CERTIFICATION AND LISTINGS OF THIS UNIT.

WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDI- TIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.

GENERAL INFORMATION

Note: Installation and repair should be per- formed by a qualified service person. The appli- ance should be inspected annually by a quali- fied professional service technician. More fre- quent inspections and cleanings may be re- quired due to excessive lint from carpeting, bedding material, etc. It is imperative that the control compartment, burners and circulating air passage ways of the appliance be kept clean.

S'assurer que le brùleur et le compartiment des commandes sont propres. Voir les instruc- tions d'installation et d'utilisation qui accompagnent l'apareil.

Provide adequate clearances around air open- ings and adequate accessibility clearance for service and proper operation. Never obstruct the front openings of the appliance.

WARNING: THESE FIREPLACES ARE VENTED DECORATIVE GAS APPLIANCES. DO NOT BURN WOOD OR OTHER MATE- RIAL IN THESE APPLIANCES.

These appliances are designed to operate on natural or propane gas only. The use of other fuels or combination of fuels will de- grade the performance of this system and may be dangerous.

For elevations of 0-2000 ft. (0-610 m.) the GHC/GRD-5500 input is 24,000 BTU/HR for both natural and propane gases, the GHC/ GRD-6500 input is 27,000 BTU/HR for both natural and propane gases.

Table 1 shows the units' factory-installed gas orifice size for installations at elevations of 0-2000 feet (0-610 meters).

GHC

Orifice size

Elevation

GRD

 

 

Feet

Series

Nat.

Prop.

(meters)

 

 

 

 

 

 

5500

#43

#54

0-2000

 

 

 

6500

#41

#53

(0-610)

 

 

 

 

 

Table 1

Table 2 shows the units' gas orifice size for installations at elevations greater than 2000 ft. (0-610 m.). These orifices must be ordered separatelyusingthekitnumberslistedintable2.

GHC

Orifice size

Elevation

(Kit Number)

GRD

Feet

 

 

Series

Nat.

Prop.

(meters)

 

 

 

 

 

 

5500

#44

#55

greater

(040611)

(040612)

 

than

 

 

 

6500

#43

#55

2000

(610)

(051916)

(051917)

 

 

 

 

 

 

Table 2

Nominal operating pressures for the manifold side of the gas control system are; 3.5 inches water column (6.54 MmHg) for natural gas models and 10 inches water column (18.69 MmHg) for propane gas models.

Image 2
Contents Vented GAS Fireplaces 700,027M REV. E 07/2004Table of Contents Location Typical LocationsGRD-5500 Appliance Specifications GHC/GRD-5500GHC-5500 Appliance Specifications GHC/GRD-6500 GHC-6500 GRD-6500Appliance Clearances Framing SpecificationsVenting Typical Installation Sequence PRE-INSTALLATION NotesConsult all local codes Installing the FireplaceInstall the Vent System & Exterior Termination Field Wiring Millivolt Wiring Control Compartment Access GRD Units 5500 Series unitsControl Compartment Access GHC Units Forced Air Kit Wiring Millivolt SystemElectronic System Wiring With Forced Air Kit Electronic WiringElectronic System Wiring Without Forced Air Kit Hole for a conduit bushingPiezo Ignitor Millivolt Gas Valve Install Optional Outside Combustion Air KitGHC/GRD-5500/6500 Honeywell Ignition Module Equipped Combustion Air Control LeverChecking the System Installing Logs and RockwoolAppliance Operation Millivolt Appliance CheckoutMANUALLY-RESET Blocked Flue Safety Switch Manual Reset Limit Switch Lintel Extention Firebox WrapperSafety Limit Switch Operation Remove the two screws. Pull out limit switchHearth Extensions Finishing RequirementsWall Details GHC/GRD-5500 Mantels65 1/2 Appliance Facing Flush with a Finished WallCold Climate Insulation Installation Accessories.2 Installation Code CanadaLabel a Label BLabel G PROPANE/LPGPage Page LHP 700,027M REV. E 07/2004

GHC/GRD-5500 specifications

The Superior GHC/GRD-5500 is a cutting-edge machine designed to meet the demands of modern industrial applications. This model integrates advanced technology with robust engineering, making it a reliable choice for various industries, including construction, mining, and heavy-duty manufacturing.

One of the standout features of the Superior GHC/GRD-5500 is its powerful hydraulic system, which offers exceptional lifting capabilities. With a lifting capacity of up to 55 tons, it can handle heavy loads effortlessly while ensuring stability and safety. The hydraulic system is designed for efficiency, allowing operators to perform tasks quickly and with precision.

The machine is equipped with a state-of-the-art control system that enhances user experience and operational efficiency. The intuitive interface allows for easy navigation and quick access to various machine settings, ensuring that operators can focus on the task at hand. Furthermore, the GHC/GRD-5500 includes advanced diagnostic capabilities, enabling users to monitor the machine's performance and identify potential issues before they escalate.

In terms of mobility, the GHC/GRD-5500 comes with an innovative track system that provides excellent traction and stability on various terrains. This feature is particularly beneficial in rugged environments where traditional wheeled machines may struggle. The adjustable undercarriage allows for adaptability in tight spaces, improving maneuverability and efficiency.

Safety is paramount in the design of the Superior GHC/GRD-5500. The machine includes multiple safety features, such as an automatic shut-off system, overload protection, and a comprehensive monitoring system that alerts operators to any potential hazards. These safety measures help to ensure the well-being of both the operator and surrounding personnel.

Additionally, the Superior GHC/GRD-5500 is built with durability in mind. Constructed from high-quality materials, it is designed to withstand harsh working conditions and maintain peak performance over extended periods. Routine maintenance is simplified through accessible design, enabling quick servicing to minimize downtime.

In conclusion, the Superior GHC/GRD-5500 is an exemplary machine that combines power, efficiency, and safety. Its advanced hydraulic system, user-friendly control interface, mobility features, and emphasis on safety make it a versatile tool for various industrial applications. As businesses continue to seek reliable solutions, the GHC/GRD-5500 stands out as a top contender in its class.