Superior GHC/GRD-5500 installation instructions Typical Locations

Page 3

Do not use these appliances if any part has been under water. Immediately call a qualified, pro- fessional service technician to inspect the ap- pliance and to replace any parts of the control system and any gas control which have been under water.

Ne pas se servir de cet appareil s'il a été plongé dans l'eau, complètement ou en partie. Appeler un technicien qualifié pour inspecter l'appareil et remplacer toute partie du système de contrôle et toute commande qui ont été plongés dans l'lau.

This appliance may be installed in an af- termarket permanently located, manufac- tured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This ap- pliance is not convertible for use with other gases, unless a certified kit is used.

Cet appareil peut être installé dans un maison préfabriquée (É.-U. seulement) ou mobile déjà installée à demeure si les réglements locaux le permettent.

Cet appareil doit être utilisé uniquement avec les types de gaz indiqués sur la plaque signalétique. Ne pas l'utiliser avec d'autres gaz sauf si un kit de con- version certifié est installé.

Millivolt appliances may be fitted at time of manufacture with either a Robertshaw millivolt gas control valve or Robertshaw electronic gas control valve. Both valves have been tested with and approved for use with these appli- ances and are listed accordingly.

A ¹⁄₈" NPT test gage connection is provided on either gas control valve adjacent to the outlet to the main burner.

Minimum inlet gas pressure to the appliance is

4.5inches water column (1.12 kPa) for natural gas and 11 inches water column (2.74 kPa) for propane for the purpose of input adjustment.

Maximum inlet gas supply pressure to the appliance is 10.5 inches water column (2.61 kPa) for natural gas and 13.0 inches water column (3.23 kPa) for propane.

The appliance must be isolated from the gas supply piping system (by closing its individual manual shut-off valve) during any pressure test- ing of the gas supply piping system at test pressures equal to or less than ¹⁄₂ psig (3.5) kPa).

The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at pres- sures in excess of ¹⁄₂ psig (3.5 kPa).

These appliances must not be connected to a chimney or flue serving a separate solid fuel burning appliance.

Do not place clothing or other materials on or near this appliance.

WARNING: FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING IN- STRUCTIONS PROVIDED IN THIS DOCU- MENT WILL RESULT IN AN IMPROPERLY INSTALLED AND OPERATING APPLI- ANCE, VOIDING ITS WARRANTY. ANY CHANGE TO THIS APPLIANCE AND/OR ITS OPERATING CONTROLS IS DANGER- OUS. IMPROPER INSTALLATION OR USE OF THIS APPLIANCE CAN CAUSE SERI- OUS INJURY OR DEATH FORM FIRE, BURNS, EXPLOSION OR CARBON MON- OXIDE POISONING.

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immedi- ately. Turn off the gas supply to the appliance and have it serviced by a qualified profes- sional, as it may not be operating correctly.

WARNING: B-VENT APPLIANCES ARE NOT DESIGNED TO OPERATE IN NEGATIVELY PRESSUREDENVIRONMENTS(PRESSURE WITHIN THE HOME IS LESS THAN PRES- SURES OUTSIDE). SIGNIFICANT NEGA- TIVELY PRESSURED ENVIRONMENTS CAUSED BY WEATHER, HOME DESIGN, OR OTHER DEVICES MAY IMPACT THE OPERATION OF THESE APPLIANCES. NEGATIVE PRESSURES MAY RESULT IN POOR FLAME APPEARANCE, SOOTING, DAMAGE TO PROPERTY AND/OR SEVERE PERSONAL INJURY. DO NOT OPERATE THESEAPPLIANCESINNEGATIVELYPRES- SURED ENVIRONMENTS.

WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES. USE CAUTION AROUND THE APPLIANCE TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CARE- FULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

WARNING: DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIALS ON OR NEAR THIS APPLIANCE.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

AVERTISSEMENT: SURVEILLER LES ENFANTS. GARDER LES VÊTEMENTS, LES MEUBLES, L'ESSENCE OU AUTRES LIQUIDES À VAPEUR INFLAMMABLES LIN DE L'APPAREIL.

WARNING: THIS APPLIANCE MAY ONLY BE FITTED WITH DOORS CERTIFIED FOR USE WITH THE APPLIANCE.

AVERTISSEMENT: POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRE CERTIFIÊES AVEC L'APPAREIL.

These appliances are equipped with an inte- gral combustion air door and actuator arm. Combustion air kits are optional. Install as shown in step 7 on page 11.

LOCATION

Typical Locations

Figure 1

In selecting the location, the aesthetic and func- tional use of the appliance are primary concerns. However, vent system routing to the exterior and access to the fuel supply are also important. Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies. Consideration should be given to traf- fic ways, furniture, draperies, etc., due to el- evated surface temperatures. The location should also be free of electrical, plumbing or other heating/air conditioning ducting.

The appliance should be mounted on a fully supported base extending the full width and depth of the unit. The appliance may be located on or near conventional construction materials. However, if installed on combustible materials, such as carpeting, vinyl tile, etc., a metal or wood barrier covering the entire bottom surface must be used.

These appliances may be used for bedroom installations in the United States and are listed accordingly. These units may not be installed in bedrooms in Canada.

3

Image 3
Contents 700,027M REV. E 07/2004 Vented GAS FireplacesTable of Contents Typical Locations LocationAppliance Specifications GHC/GRD-5500 GHC-5500GRD-5500 GHC-6500 GRD-6500 Appliance Specifications GHC/GRD-6500Framing Specifications VentingAppliance Clearances PRE-INSTALLATION Notes Typical Installation SequenceInstalling the Fireplace Install the Vent System & Exterior TerminationConsult all local codes Forced Air Kit Wiring Millivolt System Control Compartment Access GRD Units 5500 Series unitsControl Compartment Access GHC Units Field Wiring Millivolt WiringHole for a conduit bushing Electronic WiringElectronic System Wiring Without Forced Air Kit Electronic System Wiring With Forced Air KitCombustion Air Control Lever Install Optional Outside Combustion Air KitGHC/GRD-5500/6500 Honeywell Ignition Module Equipped Piezo Ignitor Millivolt Gas ValveMillivolt Appliance Checkout Installing Logs and RockwoolAppliance Operation Checking the SystemRemove the two screws. Pull out limit switch Manual Reset Limit Switch Lintel Extention Firebox WrapperSafety Limit Switch Operation MANUALLY-RESET Blocked Flue Safety SwitchFinishing Requirements Wall DetailsHearth Extensions Appliance Facing Flush with a Finished Wall Mantels65 1/2 GHC/GRD-5500Canada Installation Accessories.2 Installation Code Cold Climate InsulationPROPANE/LPG Label BLabel G Label aPage Page 700,027M REV. E 07/2004 LHP

GHC/GRD-5500 specifications

The Superior GHC/GRD-5500 is a cutting-edge machine designed to meet the demands of modern industrial applications. This model integrates advanced technology with robust engineering, making it a reliable choice for various industries, including construction, mining, and heavy-duty manufacturing.

One of the standout features of the Superior GHC/GRD-5500 is its powerful hydraulic system, which offers exceptional lifting capabilities. With a lifting capacity of up to 55 tons, it can handle heavy loads effortlessly while ensuring stability and safety. The hydraulic system is designed for efficiency, allowing operators to perform tasks quickly and with precision.

The machine is equipped with a state-of-the-art control system that enhances user experience and operational efficiency. The intuitive interface allows for easy navigation and quick access to various machine settings, ensuring that operators can focus on the task at hand. Furthermore, the GHC/GRD-5500 includes advanced diagnostic capabilities, enabling users to monitor the machine's performance and identify potential issues before they escalate.

In terms of mobility, the GHC/GRD-5500 comes with an innovative track system that provides excellent traction and stability on various terrains. This feature is particularly beneficial in rugged environments where traditional wheeled machines may struggle. The adjustable undercarriage allows for adaptability in tight spaces, improving maneuverability and efficiency.

Safety is paramount in the design of the Superior GHC/GRD-5500. The machine includes multiple safety features, such as an automatic shut-off system, overload protection, and a comprehensive monitoring system that alerts operators to any potential hazards. These safety measures help to ensure the well-being of both the operator and surrounding personnel.

Additionally, the Superior GHC/GRD-5500 is built with durability in mind. Constructed from high-quality materials, it is designed to withstand harsh working conditions and maintain peak performance over extended periods. Routine maintenance is simplified through accessible design, enabling quick servicing to minimize downtime.

In conclusion, the Superior GHC/GRD-5500 is an exemplary machine that combines power, efficiency, and safety. Its advanced hydraulic system, user-friendly control interface, mobility features, and emphasis on safety make it a versatile tool for various industrial applications. As businesses continue to seek reliable solutions, the GHC/GRD-5500 stands out as a top contender in its class.