Carrier Starting and Shutting Down Your Furnace: 58MCA, 58MVP, 58MXA Instructions

Page 5

STARTING AND SHUTTING DOWN YOUR FURNACE

Instead of a continuously burning pilot flame which wastes valuable energy, your furnace uses an automatic, hot surface ignition system to light the burners each time the thermostat starts your furnace. Follow these important safeguards:

7

Never attempt to manually light the burners with a match or other source of flame.

Read and follow the operating instructions on inside of main furnace door, especially the item that reads as follows:

Wait 5 minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B’’ in the safety information above on this furnace label. If you don’t smell gas, go to the next step.

If a suspected malfunction occurs with your gas control system, such as the burners do not light when they should, refer to the shutdown procedures on inside of main furnace door, or in the “Shutting Down Your Furnace” section and call your dealer as soon as possible.

!WARNING

If overheating occurs or the gas valve fails to shut off the gas supply, turn off the manual gas valve to the furnace BEFORE turning off the electrical sup- ply. (See Fig. 9.) Failure to follow this warning could result in a fire or explosion, and personal in- jury/death or property damage.

CHECK AIR FILTER: Before attempting to start your furnace, be sure the furnace filter is clean and in place. See “Performing Routine Maintenance” section in this manual. Then proceed as follows:

STEPS FOR STARTING YOUR FURNACE

1.Set your room thermostat to the lowest temperature set- ting. (See Fig. 8.)

2.Close the external manual gas valve. (See Fig. 9.)

CL

O

S

E

9

10

3.Turn OFF electrical supply to the furnace. (See Fig. 10.)

4.Remove main furnace door. (See Fig. 11.)

11

5.The gas valve will have a control switch to turn off and on. Turn the control switch on the gas control to the OFF position and wait 5 minutes. (See Fig. 12 or 13.) Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” on furnace label. If you don’t smell gas, go to next step.

A04150

For 58MTA and 58MVP

12

OFF

ON

 

or

For 58MCA and 58MXA

®

13

8

5

Image 5
Contents 58MCA, 58MTA, 58MVP, 58MXA MULTIPOISE, CondensingWelcome to a NEW Generation of Comfort Table of ContentsGeneral Furnace Safety Model 58MVP Furnace Upflow Position Furnace ComponentsModels 58MXA, 58MCA, and 58MTA Furnaces Upflow Position Before Starting Your Furnace Safety ConsiderationsFor 58MTA and 58MVP Starting and Shutting Down Your FurnaceFor 58MCA and 58MXA Steps for Starting Your FurnaceShutting Down Your Furnace Filtering OUT Trouble Performing Routine MaintenanceAIR Filterss Located in Blower COMPART- Ment AIR Filter Located in Filter CabinetAIR Filters Loacted in Blower COMPART- Ment Side 2930AIR Filter Located in Blower Compartment Bottom Combustion Area and Vent System 3738Heading South for the WINTER? CHECK-UP ChecklistBefore YOU Request a Service Call Page Indoor Coil AIR Conditioner or Heat Pump
Related manuals
Manual 16 pages 10.19 Kb Manual 16 pages 33.5 Kb Manual 48 pages 27.19 Kb

58MXA, 58MCA, 58MVP, 58MTA specifications

The Carrier 58MXA is an advanced heating and cooling system that exemplifies Carrier's commitment to innovation, efficiency, and comfort. Designed with the modern homeowner in mind, this gas furnace boasts a range of features that make it stand out in today's market.

One of the primary characteristics of the 58MXA is its impressive efficiency ratings. With AFUE (Annual Fuel Utilization Efficiency) ratings reaching up to 80%, the furnace ensures that homeowners can enjoy warmth during the colder months without excessive energy consumption. This efficiency not only translates to lower utility bills but also contributes to a reduced carbon footprint, making it an eco-friendly choice for environmentally conscious consumers.

The 58MXA utilizes a two-stage heating system which allows for more precise temperature control. This feature enables the furnace to operate at a lower stage for most of the heating cycle, providing comfortable warmth while conserving energy. When temperatures plummet, the system seamlessly switches to a higher stage for added heating capacity, ensuring that homes remain cozy even in extreme cold.

Furthermore, the Carrier 58MXA is engineered with advanced airflow and quiet operation in mind. Its variable-speed blower motor allows for optimal airflow throughout the home, enhancing overall comfort by distributing heat evenly in each room. This system also operates at a significantly reduced sound level compared to standard furnaces, promoting a peaceful indoor environment.

The 58MXA comes equipped with an innovative smart thermostat option, allowing users to monitor and control their home's heating remotely. This capability provides convenience and the opportunity for additional energy savings, as homeowners can adjust settings on the go or set schedules to meet their specific needs.

Durability is another hallmark of the Carrier 58MXA. Constructed with high-quality materials and backed by a manufacturer’s warranty, this furnace is built to withstand the rigors of temperature fluctuations and heavy use. Regular maintenance is also simplified, allowing homeowners to ensure optimal performance over the years.

Overall, the Carrier 58MXA is a top-of-the-line heating solution that combines efficiency, comfort, and advanced technology. Its innovative features and robust design make it an excellent choice for homeowners seeking a reliable and effective heating system. Whether for new construction or upgrading an existing home, the 58MXA is poised to provide years of dependable service.