Carrier 58BLA Welcome to a NEW Generation of Comfort, Important Facts, Rials MAY be Combustible

Page 3

WELCOME TO A NEW GENERATION OF COMFORT

Congratulations on the purchase of your new 80+% efficient oil furnace. If you are replacing an older, less efficient oil furnace, you may use 20% to 30% less oil.

In order to achieve greater efficiency, your new fur- nace operates differently in some respects than your old furnace.

One main difference between an older and newer oil furnace is in the operation of the oil burner. The new style retention head oil burner operates at twice the RPM, therefore the sound is different — not louder but probably a different pitch. This higher RPM delivers more air which burns the oil more efficiently.

You will also find the main blower comes on sooner than before. This is done with efficiency in mind but also to keep heat exchanger temperatures within allow- able limits. The more efficient furnace design heats up faster requiring a shorter blower on time.

Your new oil furnace blower is also sized for air con- ditioning and will deliver (even on heating speeds) more air than your old furnace. Depending on your ex- isting ductwork this could lead to a noticeable differ- ence in air noise. A change in ductwork could be required to reduce air noise, especially if air condition- ing is being added.

Please read the remainder of this manual in order to familiarize yourself with the operation of your furnace.

IMPORTANT FACTS

FOR YOUR SAFETY

Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance.

FOR PROPER AND SAFE OPERATION OF YOUR FURNACE:

DO NOT place combustible materials, gasoline, and/ or other flammable vapors or liquids on, against, or near the furnace or flue pipe.

DO NOT block or obstruct air openings on the fur- nace, air openings communicating with the area in which the furnace is installed, and the spacing around the furnace. These provide air for combustion and ventilation.

DO NOT store anything near or in contact with the furnace such as: spray or aerosol cans, rags, brooms, dust mops, vacuum cleaners or other cleaning tools, soap powders, bleaches, waxes or other cleaning com- pounds, plastic or plastic containers, gasoline, kero- sene, cigarette lighter fluid, dry cleaning fluids, or painting compounds.

!WARNING

Turn off the oil supply and electrical power to furnace before performing any mainte- nance or service on unit. Failure to take this precaution may result in personal injury due to electrical shock or uncontrolled oil leakage.

!CAUTION

A furnace that is installed in an insulated space must be kept free and clear of insulat- ing materials. After the furnace is installed, or whenever additional insulation is added, check that all combustion air intakes are free and clear and that all clearance dimen- sions are maintained. INSULATING MATE-

RIALS MAY BE COMBUSTIBLE.

!WARNING

Improper installation, adjustment, alter- ation, service, or maintenance can cause in- jury or property damage. Refer to this manual. For assistance or additional infor- mation consult a qualified installer, service agency, or the oil supplier.

!WARNING

Do not use this furnace if any part has been under water. Immediately call a qualified service technician to inspect the furnace and to replace any part of the control system and any oil control which has been under water. Failure to comply with this warning could lead to equipment failure, electrical shock, and a hazardous condition which may lead to bodily harm.

3

Image 3
Contents This Manual Must be Left with the Equipment User OIL FurnaceInstallation Data Rials MAY be Combustible Welcome to a NEW Generation of ComfortImportant Facts For Proper and Safe Operation of Your FurnaceHere are a FEW DO’S and do NOT’S Combustion AIR RequirementsHERE’S HOW Your Heating System Works Tempt to Light with a Match High Voltage AT Ignitor Preparing Furnace For OperationTurning Off Your Furnace Lighting Your FurnaceLubricating Motors Here is a Handy ChecklistKeeping Filters Clean FiltersPage Carrier Corporation Syracuse, New York
Related manuals
Manual 20 pages 56.84 Kb

58BLA, 58BTA, 58BMA specifications

Carrier's 58BMA, 58BLA, and 58BTA are integral components of the brand's lineup of gas furnaces, known for their efficiency, reliability, and advanced technology. These models cater to diverse heating needs while prioritizing energy savings and comfort.

The 58BMA model stands out with its two-stage heating capabilities, which allows for a more consistent indoor temperature. This feature helps to minimize temperature fluctuations, providing homeowners with a more comfortable living environment. The variable-speed blower motor enhances this experience by adjusting the airflow according to the heating demands, ensuring even distribution throughout the home.

Similarly, the 58BLA is designed for energy efficiency. Equipped with a modulating gas valve, it offers precise temperature control by adjusting the heating output according to the thermostat settings. This model is ENERGY STARĀ® certified, meaning it meets strict efficiency guidelines set by the U.S. Environmental Protection Agency. The 58BLA also features a durable heat exchanger, which contributes to its longevity and reliability.

The 58BTA model focuses on providing a robust heating solution. It incorporates a single-stage gas valve that offers reliable performance at an affordable price point. The 58BTA is a great choice for homeowners seeking dependable heating without the complexity of advanced features. Its compact design allows for easy installation in various home layouts, making it an ideal fit for many different settings.

All three models share key characteristics such as a quiet operation, which is achieved through advanced sound attenuation technology. Homeowners can enjoy a peaceful ambiance without the disruptive noise often associated with traditional furnaces. Additionally, they come equipped with an advanced control system that allows for seamless integration with smart thermostats, enhancing energy management and comfort.

In summary, the Carrier 58BMA, 58BLA, and 58BTA models represent a blend of efficiency, advanced technology, and reliability. Each model addresses varying heating needs while focusing on energy savings and homeowner comfort. With features such as variable-speed blowers, modulating gas valves, and durable heat exchangers, these furnaces exemplify Carrier's commitment to innovation in indoor climate control. Whether for high efficiency or dependable performance, these models are designed to meet the expectations of modern homeowners.