Empire Comfort Systems 5088-3 Some Helpful Warnings, Millivolt Information, Service Checks

Page 8

SOME HELPFUL WARNINGS

Use low heat output when children are nearby.

Do not cover the floor register when the furnace or pilot is turned on.

Do not restrict the flow of air around the register by placing a screen under it.

Do not dry clothes or any objects by putting them on floor register because this creates a fire hazard.

Do not hang clothes or any object above or over floor register because this too creates a fire hazard.

During warm weather months, turn to full OFF position before you cover the register with a rug, because this too creates a fire hazard.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify operation after servicing.

CAUTION

Floor register is HOT when furnace is operating. Floor register can cause burns . Keep children OFF of the floor register. (Provide fence or register guard for their protection.)

Use the FULL HEAT output during cold weather and only when no children are around. In this position, your furnace will keep running until the living area is completely heated or unless something is covering the floor register. If the register is half covered, your furnace will turn off.

MILLIVOLT INFORMATION

500 average with the thermostat OFF.

225 average with the thermostat ON.

140 minimum for valve to open.

65 minimum for pilot to stay on.

SERVICE CHECKS

Here is a list of the things you can do if your furnace stops running properly or won't turn on. DO NOT make repairs to anything not on this list; instead, call your serviceman. Only a qualified serviceman should make repairs or replace parts on gas appliances.

HAVE TROUBLE? DO THIS

1.Pilot won't light.

a.Call your gas supplier to check if the gas supply is normal.

b.Call your serviceman.

2.Pilot lights but goes out when furnace control handle is released and pops up.

a.Relight and wait 60 seconds before releasing control handle.

b.Check generator wires (see G) and screws on combination valve terminals for tightness.

c.Call your serviceman.

G

WARNING

A 6" clearance must be maintained between the flue or vent connector and beneath the entire bottom of the appliance. This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.

Flue pipe that stops on the side of the building will not vent during certain wind and/or temperature conditions and will cause flue products to accumulate under the house and can be fatal to occupants.

UNIT MUST BE WIRED AS SHOWN

If any of the original wire as supplied with appliance has to be replaced, it should be replaced by No. 18 Gauge 150° C wire or its equivalent.

This unit has a limit control connected in series with the gas valve to shut the gas off in case of inadvertent covering of the register during a heating cycle and can be positioned to reduce register temperature.

Page 8

R-1842

Image 8
Contents What to do if YOU Smell GAS Floor Furnace ModelsEffective Date November This is a Heating Appliance IntroductionSafety Information for Users of LP-GAS LP-GAS Warning OdorNo Odor Detected Odor Fade Some Points to RememberGeneral Instructions HOW Your Furnace WorksDid YOU GET EVERYTHING? HeatingUsing Your Furnace Where Theres Fire Theres Smoke -SOMETIMES Register Temperature ControlPiezo Lighting Instructions Turning Your Furnace onFor Your Safety Read Before Lighting Lighting InstructionsTo Turn OFF GAS to Appliance What to do if YOU Smell GASService Checks Unit Must be Wired AS ShownSome Helpful Warnings Millivolt InformationCare and Cleaning Keep IT CleanTurning Your Furnace OFF Turning OFF Your PilotBugs Mean Trouble Service Record Problem Date Adjustments Made or Parts ReplacedEmpire Comfort Systems, Inc

5088-3, 7088-3, 3588-3 specifications

Empire Comfort Systems offers a reliable range of heating solutions, with the models 5088-3, 7088-3, and 3588-3 standing out for their exceptional performance and innovative features. These gas-fired wall heaters are designed to provide efficient heat while maintaining user-friendly operations and stylish aesthetics.

One of the key features of the Empire Comfort Systems 5088-3 is its compact design, allowing it to fit snugly into smaller spaces without sacrificing heating capability. It boasts a powerful capacity to heat areas swiftly and effectively, making it ideal for both residential and commercial applications. The heater utilizes natural gas or propane, ensuring flexibility in fuel preference and availability.

The 7088-3 model expands upon this with additional features, including a built-in thermostat that allows for precise temperature control. This thermostat enables users to set their desired heat levels, ensuring optimal comfort without unnecessary energy expenditure. Another significant characteristic of the 7088-3 is its safety features, which include an automatic shut-off system that kicks in during abnormal conditions, providing peace of mind for users.

The 3588-3 model emphasizes efficiency, featuring advanced technologies that maximize heat output while minimizing fuel consumption. With a sleek design available in various finishes, it can seamlessly integrate into any home or office decor. The 3588-3 also prioritizes safety, equipped with a reliable ignition system that enhances operational security.

All three models feature Empire's proprietary Heating Technology, designed to distribute warmth evenly across the space, eliminating cold spots and ensuring consistent comfort. Additionally, they operate quietly, making them perfect for bedrooms, living rooms, or office environments where noise levels are a concern.

Whether you are looking for efficient heating solutions for your home or business, the Empire Comfort Systems models 5088-3, 7088-3, and 3588-3 each offer unique advantages. Their combination of advanced technology, safety features, and stylish designs positions them as leading choices in the market for reliable and effective heating solutions. With Empire Comfort Systems, achieving warmth and comfort becomes an effortless experience.