Lennox Hearth T150C operation manual Installation, Reduced Masonry Structure Clearance Alcove

Page 7

PLANNING YOUR INSTALLATION

REDUCED MASONRY STRUCTURE CLEARANCE (ALCOVE)

Your stove can be installed in a masonry structure with reduced clearances if the structure was built to National Building Code for fireplaces and chimneys (UBC 37).

The firebox of the masonry structure must be of ade- quate size to allow a minimum of 6" (152 mm) clearance to the sides and top of the stove and 2" (51 mm) clear- ance to the rear. All stove models must be installed on their original listed legs or base unless otherwise speci- fied by OMNI Testing Laboratory.

The minimum venting requirement is a listed chimney liner that extends from the flue collar of the stove to the first tile liner of the chimney where it is sealed. All joints and connections must be made airtight to prevent leaking and downdrafts.

PROTECTED WALL CLEARANCE

Some local codes will allow reduced clearances when the stove is installed adjacent to a protected wall system. Your local building official must approve the variance. Normally, the protected wall system is defined as a non- combustible material with a minimum of 1" (25.4 mm) air space behind. Check your local building codes or with a qualified installer (Ref. NFPA 211).

VENTILATION REQUIREMENTS

THE FRESH AIR REQUIREMENTS OF THIS APPLI- ANCE MUST BE MET WITHIN THE SPACE WHERE IT WILL BE INSTALLED.

Ventilation is essential when using a solid fuel burning heater. The combustion process of this heater uses oxy- gen from inside the dwelling and it may be necessary to open a window or install a vent to provide make-up air into a dwelling that is well insulated (modern construction standards have resulted in homes that are highly energy- efficient and that allow little heat loss and air transfer). Other appliances in the dwelling also contribute to re- moving air from the dwelling (i.e. clothes dryers, exhaust fans, fireplaces, and other fuel burning appliances). If the available fresh air delivery in the dwelling is insufficient to support the demands of these appliances, problems can result (i.e. Excessive negative pressure can develop in the dwelling which will affect the rate at which this appli- ance can draft [See Draft Requirements, page 9], icing can develop in some environments).

INSTALLATION

INSTALLING (OPTIONAL) MARBLE ACCENTS

See Optional Accessories, page 25 for ordering information.

Important Note; Optional marble cannot be used if tem- perature probe is used.

Marble is a natural product and therefore each piece will have its own unique character. Marble can be scratched so care should be taken to avoid putting heavy or rough objects (trivet/steamers) on the surface. If the marble should become scratched, the scratch may be removed or diminished by polishing it with jewelers rouge (which can be purchased at many hardware stores). Do not in- stall the marble before curing the paint.

The marble set consists of 2 pieces. A large piece that fits onto the stove top and a smaller piece that fits onto the ashlip (located below the fuel door).

Installation Steps:

Install the ceramic fiber blanket, gasket strips and marble set as follows:

Note: The fiber blanket and gasket strips are provided with the

stove: The marble sets are optional accessories.

1.Using scissors cut the ceramic fiber blanket so that it fits into the recess of the stovetop.

2.Place the top marble piece onto the ceramic fiber blanket.

3.Place the gasket strips into the recess of the ashlip so that they are evenly spaced. This will slightly ele- vate the marble so that it is not making direct surface contact. Note: Insulation is not required in this area.

4.Place the ashlip marble onto gasket strips in ashlip recess.

PAGE 7

Image 7
Contents Installation and Operation Manual Important Warnings Table of Contents Questions to ASK Local Building Official Planning Your InstallationSmoke Detectors Standard Parallel Hearth PAD Shown Floor ProtectionUSA Requirements Canada RequirementsSelecting a Location Corner Installation Parallel InstallationCombustible Wall Clearance Protected Wall Clearance InstallationInstalling Optional Marble Accents Reduced Masonry Structure Clearance AlcoveTypes of Chimneys Acceptable Connector Pipe for INSTALLA- TionsChimney Inspection Draft Requirements Chimney Height RequirementsResidential Installation Diagram Page Catalytic Combustor Product Features and ControlsPrimary AIR Control Primary Air Control KnobGlass Care and OperationFuel Door Primary AIR Control Door OperationBREAK-IN Period HOW to Start and Maintain a FireBypass Damper Control RefuelingWood Storage FuelBurn Recommended Fuel Seasoning GuideDoor and Glass Gaskets MaintenanceSmall Area Paint TOUCH-UP ASH Removal and DisposalStove Seams Catalyst ReplacementCleaning Blower Intake Creosote Formation and Need for RE- MovalCatalytic Combustor Troubleshooting TAR and Liquid Creosote Leaking from Metal Flue Joints Catalyst Substrate CrackingCatalyst Substrate Catalyst PeelingSpecifications Model T150C Model Description Replacement Parts for Model T150CFirebrick 1 ¼ thick Component Diagrams T150CPart Qty Dimensions FB-1 Top View Showing Brick InstalledTemperature Probe TP-FS Optional Accessories T150CSAFETY/LISTING Label EPA Label Ownership Records Service and Maintenance LOGWest Taft Avenue Orange, CA

T150C specifications

The Lennox Hearth T150C is a premium heating solution that epitomizes efficiency, reliability, and modern design. This wood-burning fireplace insert is crafted to enhance both the aesthetic appeal and functional warmth of any living space. With its elegant look and cutting-edge technologies, the T150C provides homeowners with an exceptional heating experience.

One of the standout features of the Lennox Hearth T150C is its high-efficiency combustion system. This system is designed to maximize heat output while minimizing emissions, making it an environmentally friendly choice for wood burning. The insert boasts an impressive efficiency rating, allowing homeowners to utilize less wood while still achieving a warm and cozy atmosphere. This efficient burning technology also means that less smoke and ash are produced, making it easier to maintain and keep clean.

The T150C features a large viewing window, framed by a sleek cast iron door, which allows for an unobstructed view of the mesmerizing flames. The design not only enhances the fireplace’s aesthetic appeal but also provides an effective heat radiating feature. The ceramic glass window can withstand high temperatures, ensuring both safety and durability while allowing the beauty of the fire to be enjoyed from several angles.

Additionally, the T150C is designed with adjustable air controls that allow users to customize the fire's heat output and burn time. This feature provides flexibility in managing the environment and comfort levels in the home. Its intuitive design makes it easy for anyone to operate, ensuring that users can enjoy a warm fire with minimal effort.

Another highlight of the Lennox Hearth T150C is its compact design, making it suitable for various room sizes. Its streamlined look and modern finish allow it to seamlessly integrate with both traditional and contemporary home decors.

Overall, the Lennox Hearth T150C wood-burning fireplace insert combines efficiency, elegance, and advanced heating technology, making it an ideal choice for anyone looking to enhance their home with a reliable and attractive source of warmth. With its blend of functionality and style, the T150C sets a standard for wood-burning fireplaces in the market.