Lennox Hearth 1003C operation manual Catalytic Combustor System Components, Damper Assembly

Page 27

COMPONENT DIAGRAMS - Model 1003C

Catalytic Combustor System Components

Secondary Air Tube

Bypass Damper Control

Tunnel Baffle

Positioning

Stops

Damper

Door

Catalytic

Combustor

Catalyic Combustor

Retainer Clip

Damper Assembly

Setscrews

Bypass Damper

Control Rod

Damper Blade Assembly (Linkage)

Damper Door

Air Intake Draft Module

Door Assembly

Handle Assembly (P/N LB-102214)

Nut

Torque Plate

Handle

Rod Washers

Coil Handle

PAGE 27

Image 27
Contents 775003M, Rev. P, 11/03 EPA Certified Catalytic Wood Burning StoveImportant Warnings Table of Contents Planning Your Installation Smoke DetectorsSelecting a Location Standard Parallel Hearth PAD Shown Floor ProtectionUSA Requirements Canada RequirementsCombustible Wall Clearances Alcove Clearances Reduced Masonry Structure Clearance AlcoveProtected Wall Clearance Stove Outside Air Floor Duct Floor Protector InstallationAIR Intake Cover Outside AIRRemove ASH Drawer Clip Acceptable Connector Pipe for INSTALLA- TionsSecuring the Stove to the Floor Grounding Stove2’ by 10’ Rule for Vent Termination Chimney InspectionVapor Barrier At Chimney Penetration Chimney Height RequirementsDraft Requirements Draft Test ProcedureImportant Notes Using 6 152 mm Diameter Type L-Vent Connector PipeResidential Standard Manufactured Mobile Home StandardInside wall of the Solid-Pak chimney. The inner end Sides, to maintain the 9 228.6 mm air space. When fasteningMethod B 228.6 mm Clearance to Combustible Wall Member Wall pass-through with a minimum 9 228.6 mm air space beCare and OPERATI0N Care and Operation Fuel DoorGlass BREAK-IN Period HOW to Start and Maintain a FireBurn Recommended Fuel Catalytic Temperature ProbeRefueling Bypass Damper ControlFuel MaintenanceReplacing Glass Door / Glass Gasket and ASH Drawer GAS- KETSide Cut-Away View of Firebox Catalyst ReplacementTroubleshooting Catalyst Substrate Catalyst PluggingCatalyst Deactivation Catalyst Substrate CrackingOverfiring Caused From Improper Installation Overfiring DamageOverfiring Caused From Improper Operation Fire Box Size Cubic feet Specifications Model 1003CItem no Description Replacement Parts List Model 1003C Catalytic Combustor System Components Damper AssemblyVariable Speed Control, Dial-A-Temp Outside Air Floor Duct OAFD-SStove-Stat Kit SSK Blower Kit BK-100SAFETY/LISTING Label EPA Label Ownership Records Service and Maintenance LOGWest Taft Avenue Orange, CA