Trane SS-PRC003-EN manual DataSystem

Page 18

Performance

DataSystem

Table PD-5 — Gross Cooling Capacities (MBh) TTA100A Condensing Unit withTWE100A Air Handler

 

 

 

 

 

(I-P)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AmbientTemperature (°F)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

 

 

 

 

 

95

 

 

 

 

 

105

 

 

 

 

 

115

 

 

 

Enter.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dry

 

 

 

 

 

 

 

 

 

 

 

 

Entering Wet Bulb (°F)

 

 

 

 

 

 

 

 

 

 

 

CFM

Bulb

 

 

61

67

73

 

61

 

67

 

73

 

61

67

73

 

61

 

67

73

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Airflow

(°F)

TGC

SHC

TGC

SHC

TGC

SHC

 

TGC

SHC TGC SHC TGC SHC

TGC SHC

TGC

SHC

TGC

SHC

 

TGC SHC TGC SHC TGC SHC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

104.7

81.7

115.8

68.5

127.7

46.8

 

100.9

79.7

111.5

66.8

 

123.0

45.1

96.8

77.7

107.1

65.0

118.1

43.5

 

92.4

75.5

102.5

63.2

112.9

41.7

3025

80

105.2

95.0

116.1

78.6

127.8

61.1

 

101.5

93.1

111.9

76.8

 

123.2

59.3

97.5

91.1

107.5

75.0

118.3

57.5

 

93.3

89.0

102.9

73.0

113.3

55.6

 

85

106.9

106.9

116.3

92.0

128.1

74.9

 

103.8

103.8

112.1

90.1

 

123.5

73.1

100.4

100.4

107.7

88.1

118.7

71.3

 

96.9

96.9

103.1

86.1

113.7

69.5

 

90

112.3

112.3

116.8

105.4

128.4

88.7

 

109.1

109.1

112.7

103.5

123.8

86.9

105.7

105.7

108.4

101.6 119.0

85.1

 

102.1 102.1 104.1

99.7

113.8

82.9

 

75

106.8

85.3

118.0

67.1

129.8

47.6

 

102.8

83.3

113.6

65.3

 

124.9

46.0

98.6

81.2

109.0

63.4

119.8

44.2

 

94.2

79.1

104.3

61.5

114.5

42.4

3350

80

107.5

99.9

118.3

82.1

130.0

63.0

 

103.7

98.0

113.9

80.3

 

125.2

61.2

99.6

96.0

109.4

78.4

120.2

59.4

 

95.4

93.9

104.5

76.0

115.0

57.5

 

85

110.4

110.4

118.4

96.5

130.3

78.1

 

107.1

107.1

114.1

94.6

 

125.5

76.3

103.7

103.7

109.6

92.6

120.6

74.5

 

100.0 100.0 104.9

90.5

115.4

72.6

 

90

116.1

116.1

119.2

111.2

130.5

93.1

 

112.7

112.7

115.0

109.3

125.6

90.9

109.1

109.1

110.7

107.4 120.7

89.0

 

105.4 105.4 106.3

105.4 115.6

87.0

 

75

108.6

88.8

119.7

69.3

131.5

48.5

 

104.5

86.8

115.2

67.4

 

126.5

46.8

100.2

84.7

110.6

65.5

121.2

44.9

 

95.6

82.4

105.7

63.5

115.8

43.0

3675

80

109.5

104.7

120.1

85.4

131.7

64.8

 

105.6

102.7

115.4

83.2

 

126.8

63.1

101.6

100.7

110.8

81.2

121.7

61.2

 

97.0

97.0

105.9

79.1

116.4

59.3

 

85

113.5

113.5

120.3

100.8

132.1

81.1

 

110.1

110.1

115.8

98.8

 

127.2

79.3

106.4

106.4

111.2

96.8

122.1

77.5

 

102.6 102.6 106.5

94.8

116.8

75.6

 

90

119.4

119.4

121.4

116.8

132.2

96.8

 

115.8

115.8

117.2

114.9

127.3

94.9

112.1

112.1

112.2

112.2 122.3

92.9

 

108.2 108.2 108.3

108.3 117.0

90.9

 

75

110.1

92.1

121.2

71.3

132.9

49.2

 

105.9

90.0

116.6

69.4

 

127.8

47.4

101.5

87.9

111.9

67.5

122.4

45.5

 

96.9

85.7

106.9

65.6

116.8

43.6

4000

80

111.4

109.2

121.4

88.2

133.2

66.6

 

107.5

107.3

116.9

86.2

 

128.2

64.8

103.1

103.1

112.1

84.2

123.0

63.0

 

99.3

99.3

107.2

82.0

117.6

61.1

 

85

116.3

116.3

121.9

105.0

133.6

84.0

 

112.7

112.7

117.4

103.0

128.6

82.2

108.9

108.9

112.7

101.0 123.4

80.4

 

105.0 105.0 107.9

98.9

117.8

78.0

 

90

122.3

122.3

123.5

122.3

133.8

100.7

 

118.6

118.6

118.7

118.7

128.8

98.7

114.7

114.7

114.8

114.8 123.7

96.8

 

110.7 110.7 110.8

110.8 118.3

94.7

Equal TGC and SHC values constitute dry coil conditions. Total Gross Cooling (TGC) shown to the left is not applicable. In this case the Sensible Heat Capacity (SHC) is the total capacity.

All capacities shown are gross and have not considered indoor fan heat.

To obtain net cooling capacities subtract indoor fan heat.

TGC = Total Gross Cooling Capacity

SHC = Sensible Heat Capacity

Table PD-5 — Gross Cooling Capacities (kW) TTA100A Condensing Unit withTWE100A Air Handler

 

 

 

 

(SI)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AmbientTemperature (°C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

29.4

 

 

 

 

35.0

 

 

 

 

40.6

 

 

 

 

46.1

 

 

 

Enter.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dry

 

 

 

 

 

 

 

 

 

 

 

Entering Wet Bulb (°C)

 

 

 

 

 

 

 

 

 

 

 

m3/h

Bulb

 

 

16.1

19.4

22.8

16.1

 

19.4

22.8

16.1

19.4

22.8

16.1

19.4

22.8

 

Airflow

(°C)

TGC

SHC

TGC

SHC

TGC

SHC

TGC

SHC TGC SHC TGC SHC

TGC SHC

TGC SHC TGC SHC

TGC SHC

TGC

SHC

TGC

SHC

 

24

30.7

23.9

33.9

20.1

37.4

13.7

29.5

23.3

32.7

19.6

36.0

13.2

28.3

22.7

31.4

19.0

34.6

12.7

27.1

22.1

30.0

18.5

33.1

12.2

5139

27

30.8

27.8

34.0

23.0

37.4

17.9

29.7

27.3

32.8

22.5

36.1

17.4

28.5

26.7

31.5

22.0

34.6

16.8

27.3

26.1

30.1

21.4

33.2

16.3

 

29

31.3

31.3

34.0

26.9

37.5

21.9

30.4

30.4

32.8

26.4

36.2

21.4

29.4

29.4

31.5

25.8

34.7

20.9

28.4

28.4

30.2

25.2

33.3

20.3

 

32

32.9

32.9

34.2

30.9

37.6

26.0

31.9

31.9

33.0

30.3

36.2

25.5

30.9

30.9

31.8

29.8

34.8

24.9

29.9

29.9

30.5

29.2

33.3

24.3

 

24

31.3

25.0

34.5

19.7

38.0

13.9

30.1

24.4

33.3

19.1

36.6

13.5

28.9

23.8

31.9

18.6

35.1

12.9

27.6

23.1

30.5

18.0

33.5

12.4

5692

27

31.5

29.3

34.6

24.0

38.1

18.5

30.3

28.7

33.4

23.5

36.7

17.9

29.2

28.1

32.0

23.0

35.2

17.4

27.9

27.5

30.6

22.3

33.7

16.8

 

29

32.3

32.3

34.7

28.3

38.1

22.9

31.4

31.4

33.4

27.7

36.8

22.3

30.3

30.3

32.1

27.1

35.3

21.8

29.3

29.3

30.7

26.5

33.8

21.3

 

32

34.0

34.0

34.9

32.6

38.2

27.2

33.0

33.0

33.7

32.0

36.8

26.6

31.9

31.9

32.4

31.4

35.3

26.1

30.9

30.9

31.1

30.9

33.8

25.5

 

24

31.8

26.0

35.1

20.3

38.5

14.2

30.6

25.4

33.7

19.7

37.0

13.7

29.3

24.8

32.4

19.2

35.5

13.2

28.0

24.1

30.9

18.6

33.9

12.6

6244

27

32.1

30.6

35.2

25.0

38.6

19.0

30.9

30.1

33.8

24.4

37.1

18.5

29.7

29.5

32.4

23.8

35.6

17.9

28.4

28.4

31.0

23.2

34.1

17.4

 

29

33.2

33.2

35.2

29.5

38.7

23.7

32.2

32.2

33.9

28.9

37.2

23.2

31.2

31.2

32.6

28.4

35.8

22.7

30.0

30.0

31.2

27.8

34.2

22.1

 

32

35.0

35.0

35.6

34.2

38.7

28.3

33.9

33.9

34.3

33.7

37.3

27.8

32.8

32.8

32.8

32.8

35.8

27.2

31.7

31.7

31.7

31.7

34.3

26.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24

32.2

27.0

35.5

20.9

38.9

14.4

31.0

26.4

34.2

20.3

37.4

13.9

29.7

25.7

32.8

19.8

35.8

13.3

28.4

25.1

31.3

19.2

34.2

12.8

6796

27

32.6

32.0

35.6

25.8

39.0

19.5

31.5

31.4

34.2

25.2

37.5

19.0

30.2

30.2

32.8

24.6

36.0

18.4

29.1

29.1

31.4

24.0

34.4

17.9

 

29

34.0

34.0

35.7

30.7

39.1

24.6

33.0

33.0

34.4

30.2

37.7

24.1

31.9

31.9

33.0

29.6

36.1

23.5

30.7

30.7

31.6

29.0

34.5

22.8

 

32

35.8

35.8

36.2

35.8

39.2

29.5

34.7

34.7

34.8

34.8

37.7

28.9

33.6

33.6

33.6

33.6

36.2

28.3

32.4

32.4

32.4

32.4

34.6

27.7

Equal TGC and SHC values constitute dry coil conditions. Total Gross Cooling (TGC) shown to the left is not applicable. In this case the Sensible Heat Capacity (SHC) is the total capacity.

All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling capacities subtract indoor fan heat.

TGC = Total Gross Cooling Capacity SHC = Sensible Heat Capacity

18

SS-PRC003-EN

Image 18
Contents Split System Cooling Units Standardized Cabinets Manufacturing ControlDesigning the Details FiltersContents Low Ambient Cooling Operation Features and BenefitsCondensing Unit Options Air Handlers Offer More FlexibilityOdyssey Lowers Installation Costs Micro Controls ReliaTel MicroElectromechanical Controls QualityAnd ReliabilityTesting We test designs at our factory not on our customersVariTrac Low Ambient Cooling Clearance RequirementsBlower Rotation Typical HorizontalAir Handler ApplicationHeating Capacity Selection ProcedureCooling Capacity Air Delivery SelectionModel Number Description Split System Condensing Unit Model NomenclatureAir Handler Model Nomenclature General Data Table GD-1 General DataTable GD-2- General Data Table GD-3 General Data Table GD-4 General DataPerformance DataSystemTTA075A Condensing Unit withTWE100AAir Handler TGC SHC SHC TGC SHC TGC SHCDataSystem TTA085A Condensing Unit withTWE100AAir Handler DataSystem TTA100B Condensing Unit withTWE100BAir Handler DataSystem DataSystem TTA125B Condensing Unit withTWE100B Air Handler TTA125B Condensing Unit withTWE155B Air Handler TTA155B Condensing Unit withTWE155B Air Handler DataSystem DataSystem DataSystem TTA200B Condensing Unit with TWE200B Air Handler Bulb Entering Wet Bulb Temperature C M3/h Airflow EnterPerformance Data TTA075A Condensing Unit Only I-PTable PD-17- Cooling Performance MBh TTA085A Condensing Unit Only SI Table PD-18 Cooling Performance kWTable PD-19 Cooling Performance MBh TTA100A Condensing Unit Only I-PTTA100A Condensing Unit Only SI Table PD-19 Cooling Performance kWTTA100B Condensing Unit Only SI Table PD-20 Cooling Performance kWCap. Btuh/1000 85.9 94.9 Cap. Btuh/1000 95.7Cap. Btuh/1000 90.8 105 Cap. Btuh/1000 80.9 89.5 98.5Cap. Btuh/1000 48.9 54.0 59.3 64.9 70.8 OD Unit Power kW Head pressure kPA 192673.7 80.1 OD Unit KW Head press Psig Cap. Btuh/1000 46.5Table PD-23 Cooling Performance MBh TTA125B Condensing Unit Only I-PTTA125B Condensing Unit Only SI Table PD-23 Cooling Performance kWTTA155B Condensing Unit Only I-P Table PD-24 Cooling Performance MBh45.2 49.5 54.0 58.6 63.4 OD Unit Power kW ODTemp Suction ReferenceTemperature F Head press. Psig56.0 60.8 65.9 OD Unit Power kW 56.1 60.5 OD Unit Power kW96.8 23.7 26.0 28.4 30.8 OD Unit Power kW Head pressure kPA 172179.5 OD Unit KW Head press. Psig80.1 OD Unit Power kW 63.6 69.5 75.6 82.0 88.6 OD Unit Power kW66.2 72.0 78.1 84.4 OD Unit Power kW 59.3 64.6 70.1 75.9 OD Unit Power kWPerformance Data Table PD-29- Evaporator Fan Performance TWE050A I-P Table PD-29- Evaporator Fan Performance TWE050A SITable PD-30- Blower Speeds TWE050A Table PD-31 Evaporator Fan Performance TWE075A SI Table PD-31- Evaporator Fan Performance TWE075A I-PTable PD-29 Table PD-32 Blower Speeds TWE075ATable PD-33 Evaporator Fan Performance TWE100A, TWE100B I-P Table PD-33Table PD-34 Blower Speeds TWE100A, TWE100B Table PD-36- Blower Speeds TWE155B Table PD-35 Evaporator Fan Performance TWE155B I-PTable PD-35 Evaporator Fan Performance TWE155B SI Motor SheaveTurns Open Drive StandardTable PD-37 Table PD-37 Evaporator Fan Performance TWE200B,E I-PTable PD-37- Evaporator Fan Performance TWE200B,E SI Table PD-38- Blower Speeds TWE200B,EStraight 1400 UnitModel No TWE050 1800Table PD-41 Auxiliary Electric Heat Capacity Air Handler Table ED-4 Unit Wiring Air Handler Table ED-1 Unit Wiring Condensing UnitsTable ED-3 Electrical Characteristics Motors Air Handler Electrical DataMinimum Maximum Model No Electric Heat DataHeater With UnitTTA075A/TWE075A TTA085/TWE075A TTA085/TWE100A Jobsite ConnectionsTTA050/TWE050A 2TTA075A/TWE155BTypical Wiring Air HandlerAir Handler Condensing Unit Single Compressor Typical Wiring Condensing Unit Dual Compressor Typical Wiring Dimensional Data Figure DD-1 TTA075 Condensing UnitsFigure DD-2 TTA085A and 100A Condensing Units Figure DD-3 TTA100C Condensing Units Figure DD-4 TTA100B and TTA125B Condensing Units Figure DD- 5- TTA155B Condensing Unit Figure DD-6 TTA155C Condensing Units Figure DD-7 TTA200B Condensing Unit Figure DD-8 TTA200F Condensing Unit 19-1/2 15-7/8 Table DD-1 Air Handler Dimensions in. mmTable DD-1 203.20 495.30 660.40 403.23Table DD-2 Air Handler Dimensions in. mm Table DD-2Table DD-3 Air Handler Dimensions in. mm TWE100A, 100BFigure DD-12- TWE155B and 200B Air Handlers Table DD-4- Air Handler Dimensions in. mm Table DD-420 7/8 89 1/4 71 7/8 92 5/8 30 1/251 7/8 59 1/8 1826 2353 775Figure DD-16 Electric Heater for TWE155 and 200 Air Handlers 18 1/8Table DD-6 Discharge Plenum Grille Dimensions in. mm Weights Table W-1 Unit and Corner Weights Net Lbs kgTableW-2 AccessoryWeights Net Lbs kg Table W-3 Air Handlers and Corner Weights lb1 kg Table W-4 Accessory Weights Net Lbs kgVertical TWE050, 075 TWE155 Casing MechanicalGeneral Refrigeration System Dual Manifolded CompressorsThermostat ControlsZone Sensor LowAmbient OperationEvaporator Coil Mechanical SpecificationsAccessories Evaporator FanSupersedes PL-UN-SS-PRC003-EN-0104 Literature Order NumberFile No PL-UN-SS-PRC003-EN-0606 Stocking Location Electronic Only

SS-PRC003-EN specifications

The Trane SS-PRC003-EN is a high-efficiency commercial HVAC solution designed to cater to a wide variety of industrial applications. Known for its robust engineering and innovative design, this unit provides reliable climate control, ensuring optimal indoor environments in commercial spaces, manufacturing plants, and large facilities.

One of the standout features of the SS-PRC003-EN is its advanced inverter technology. This variable-speed compressor allows for precise cooling and heating adjustments based on real-time demand, which not only enhances system efficiency but also significantly reduces energy consumption. This capability not only minimizes operational costs but also contributes to a more sustainable energy profile, aligning with growing environmental concerns.

Another notable characteristic is its user-friendly control system. The unit is equipped with intuitive interfaces that allow facility managers to monitor and adjust settings remotely. This functionality ensures optimal performance, facilitates maintenance, and offers diagnostics that help identify potential issues before they lead to system failure.

Moreover, the SS-PRC003-EN features a built-in air filtration system that improves indoor air quality. It effectively removes dust, pollutants, and allergens from the air, contributing to healthier environments for occupants. This is particularly critical in commercial settings where many individuals congregate, ensuring compliance with health and safety regulations.

The design also emphasizes noise reduction technology. The unit operates at whisper-quiet levels, minimizing disruption in work environments and enhancing comfort for occupants. This is achieved through a combination of sound-absorbing materials and engineered airflow paths.

Additionally, the Trane SS-PRC003-EN is constructed with durability in mind. It resists corrosion, withstands harsh environmental conditions, and maintains performance longevity, making it a reliable choice for facilities that require constant operation.

With its combination of efficiency, advanced technology, user-friendly controls, and superior air quality management, the Trane SS-PRC003-EN stands out as a market leader in commercial HVAC systems. It offers businesses the performance they need while also promoting energy savings and environmental stewardship, making it an invaluable addition to any commercial infrastructure.