Honeywell F115 specifications Parts List, Electrical Shock Hazard Power source can shock

Page 6

F114 AND F115 CEILING SURFACE MOUNTED MEDIA AIR CLEANERS

CAUTION

Electrical Shock Hazard.

Power source can shock.

• Turn off the power to the air cleaner when cleaning or servicing.

• Stand on a stable platform when working with the air cleaner.

CAUTION

Eye Exposure.

Harmful dust can obstruct or injure unshielded eyes.

A CPZ™ module usually releases dust when it is handled.

Always wear safety glasses when installing or removing CPZ™ canisters.

1.Grasp the edge of the air cleaner cover near the plenum and remove the cover from the support brackets. Set it aside.

2.Remove the prefilters.

3.Check the prefilters and replace them if they are fully coated with dust and lint (approximately every 1 to 3 months).

4.Replace the CPZ™ cartridge when a continuous noticeable odor is emitted from the air cleaner (approximately every 4 to 12 months).

5.Replace the primary filter when there is a noticeable loss of air volume circulation (approximately every 10 to 24 months).

6.Reassemble the air cleaner and turn the power on.

PARTS LIST

Refer to Table 2 or 3 and Fig. 6 or 7 for a parts list and an exploded view of the parts.

Table 2. F114 Ceiling Surface Mounted Media Air Cleaner Parts List.

Fig. Reference

Description

Pack Qty

Order Number

Reference No.

No.

 

 

 

 

 

 

 

 

 

1

Inspection plate cover

1

32000243

901402

 

 

 

 

 

2

Three-position switch

1

32000244

901533

 

 

 

 

 

3

Blower wheel

1

32000245

902515A

 

 

 

 

 

4

120V, 60 Hz, 2-speed motor

1

32000250

906079

 

 

 

 

220-240V, 50/60 Hz motor

1

--

--

 

 

 

 

 

 

5

Mid-plate

1

32000241

900204

 

 

 

 

 

6

Prefilter

2

32000223

32002

 

 

 

 

 

7

HEPA filter (requires 2)

1

32000206

21500

 

 

 

 

D.O.P. Particle filter (requires 2)

1

32000217

28710

 

 

 

 

 

 

8

Disposable CPZ cartridge (requires 2)

1

32000232

36210

 

 

 

 

 

9

Filter holding plate with stud and nut

1

32000247

905037

 

 

 

 

 

10

Lid/Cover

1

32000375

--

 

 

 

 

 

11

Grill Cover

1

32000251

911352

 

 

 

 

 

12

Knob

1

32000242

901400

 

 

 

 

 

68-0201-2 Revised 11-07

6

Image 6
Contents Features GeneralSpecifications Ordering InformationPlanning the Installation Installation Service OperationParts List Electrical Shock Hazard Power source can shockF114 Ceiling Surface Mounted Media Air Cleaner Parts List Plenum Early Models F115 Ceiling Surface Mounted Media Air Cleaner Parts List Reference NoPlate Limited TWO-YEAR Warranty How to make a warranty claim or have questions answered