Operation

INSTALL PRE-FILTER BEFORE INITIAL OPERATION. Refer to “How to Install and Replace Filters” section for proper installation.

To encourage operation on higher speeds, the Honeywell

18150 series air cleaner has been designed to operate very quietly and effectively without a cool exhaust draft. To operate, press the POWER button to HIGH speed for a few seconds, and then leave it on high for faster, more powerful air circulation, or move it to a lower setting as desired.

HIGH MED

HEPA FILTER POWER

Intelli-CheckFilterMonitors

This air cleaner is equipped with Intelli-Check Filter Monitors to serve as a convenient guideline for replacement of the pre-filter and HEPA filter based on the air cleaner’s hours of use and operating speed. This is beneficial because a filter’s life depends on the amount of air and contaminants drawn through it. The monitors have the ability to indicate the amount of expected filter life used. Once a filter has reached the end of its expected life, its light will remain on until it is RESET. You may unplug the air cleaner without interrupting the filter monitors.

The Intelli-CheckFilter Monitors count the expected filter life based on an assumed average operating time of 12 hours a day on medium speed. Therefore, it will indicate replacement of the Pre-filter in about 3 months, and the HEPA filter in about 1 year and 9 months. Depending upon your individual usage (environment, hours and speed of operation), you may need to check and replace the filters more or less frequently.

To CHECK Expected Filter Life Usage

When the unit is turned on, quickly press the filter monitor button. The pre-filter light will flash up to 3 times and the HEPA filter light will flash up to 4 times, depending upon how much expected filter life has been used.

PREFILTER:

 

1 flash

= from new, up to 1/3 expected life used up

2 flashes

= between 1/3 and 2/3 expected life used up

3 flashes

= between 2/3 and all of expected life used up

Remains on

= time to replace pre-filter

HEPA FILTER:

 

1 flash

= from new, up to 1/4 expected life used up

2 flashes

= between 1/4 and 1/2 expected life used up

3 flashes

= between 1/2 and 3/4 expected life used up

4 flashes

= between 3/4 and all of expected life used up

Remains on

= time to replace HEPA filter

To RESET Filter Monitor

When the filter monitor light remains on, it is time to replace the filter and reset the filter monitor. With the unit powered on, press and hold the filter monitor button down for approximately 5 seconds until the light turns off.

Image 4
Contents Portable Hepa Air Cleaner Important Safety Instructions … For Best Performance … Congratulations …Construction … To Reset Filter Monitor Operation …Intelli Check Filter Monitors … To Check Expected Filter Life UsageFilter Replacement Intervals … Replacement Filters…Storage How to Install and Replace the Filters … TroubleshootingYear Limited Warranty… Honeywell Hepa Air Cleaners Model No SeriesReturns Department Ship to Mail Questions or Comments to Honeywell